DYDao-Hui Yang

Dao-Hui Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dao-Hui Yang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Kupffer-phase Sonazoid ultrasound LI-RADS for liver cancer: diagnostic performance and algorithm modification

    by Xuejun Chen, Daohui Yang, Lewu Lin, Aiqin Wu, Linjin Huang, Lijuan Mao, Hansheng Xia, Qing Lu

    Purpose: This study aimed to enhance the noninvasive identification of hepatocellular carcinoma (HCC) by modifying the Sonazoid-based contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) through integration of Kupffer-phase (KP) imaging and optimization of washout timing criteria.Methods: This retrospective two-center study enrolled 558 patients with solitary liver nodules who underwent Sonazoid-based CEUS between August 2022 and September 2024. CEUS features were assessed according to LI-RADS v2017 using predefined washout time windows (2, 5, and 10 minutes). A modified LI-RADS algorithm incorporating KP hypoenhancement was developed. Interobserver agreement was evaluated using the Cohen kappa. Diagnostic performance metrics (area under the curve [AUC], sensitivity, specificity, and positive predictive value) were compared between the modified CEUS LI-RADS algorithms and the Japan Society of Hepatology (JSH) and Korean Liver Cancer Association (KLCA) guidelines using the McNemar and DeLong tests.Results: For key CEUS features, interobserver agreement was moderate to almost perfect (κ=0.580–0.815). The modified CEUS LI-RADS-10min algorithm demonstrated superior performance over the other algorithms. By reclassifying LR-M nodules with early washout and mild KP hypoenhancement as LR-5, the modified CEUS LI-RADS-10min algorithm achieved the highest diagnostic performance for HCC (AUC, 0.782), improving sensitivity while maintaining specificity (73.7%). Its performance was comparable to that of the KLCA guideline. The JSH guidelines showed the highest sensitivity (91.7%) but the lowest specificity (53.9%).Conclusion: Integrating KP hypoenhancement with a 10-minute washout window improves the sensitivity of Sonazoid-based CEUS LI-RADS for diagnosing HCC while preserving specificity, providing feasible refinement aligned with established guidelines and promoting standardization.


  • Open Access

    Ultrasound-Based Deep Learning Radiomics to Predict Cervical Lymph Node Metastasis in Major Salivary Gland Carcinomas

    by Huan-Zhong Su, Long-Cheng Hong, Zhi-Yong Li, Qiao-Min Fu, Yu-Hui Wu, Shao-Feng Wu, Zuo-Bing Zhang, Dao-Hui Yang, Xiao-Dong Zhang


  • Open Access

    Clinical Application of High-Frame-Rate Vector Flow Imaging in Evaluation of Carotid Atherosclerotic Stenosis

    by Yi-Jie Qiu, Juan Cheng, Qi Zhang, Dao-Hui Yang, Dan Zuo, Feng Mao, Ling-Xiao Liu, Yi Dong, Si-Qi Cao, Wen-Ping Wang

    Objective: This study seeks to evaluate the value of the high-frame-rate vector flow imaging technique in assessing the hemodynamic changes of carotid atherosclerotic stenosis in aging people (>60 years old). Methods: Aging patients diagnosed with carotid atherosclerotic stenosis who underwent carotid high-frame-rate vector flow imaging examination were prospectively enrolled. A Mindray Resona7s ultrasound machine equipped with high-frame-rate vector flow function was used for ultrasound evaluation. First, B mode ultrasound and color Doppler flow imaging were used to evaluate carotid stenosis. Then, the vector arrows and flow streamline detected by V Flow were analyzed and the wall shear stress values (Pa) at the carotid stenosis site were measured. All patients were divided into symptomatic and asymptomatic groups according to whether they had acute/subacute stroke or other clinical symptoms within 2 weeks before ultrasound examination. The results of digital subtraction angiography or computed tomography angiography were used as the gold standard. The stenosis rate was calcified, according to North American Symptomatic Carotid Endarterectomy Trial criteria. The diagnostic values of wall shear stress, conventional ultrasound, and the combined diagnosis in carotid atherosclerotic stenosis were compared. Results: Finally, 88 patients with carotid atherosclerotic plaque were enrolled (71 males (80.7%), mean age 67.6 ± 5.4 years). The success rate of high-frame-rate vector flow imaging was 96.7% (88/91). The WSS value of symptomatic carotid stenosis (1.4 ± 0.15 Pa) was significantly higher than that of asymptomatic carotid stenosis (0.80 ± 0.08 Pa) (p < 0.05). Taking the wall shear stress value > 0.78 Pa as the diagnostic criteria for symptomatic carotid atherosclerotic plaque, the area under receiver operating characteristic curves was 0.79 with 87.1% sensitivity and 69.6% specificity. The area under receiver operating characteristic curves of the combined diagnosis (0.966) for differentiating severe carotid atherosclerotic stenosis was significantly higher than that of conventional ultrasound and WSS value, with 89.7% sensitivity and 93.2% specificity (p < 0.05). Conclusion: As a non-invasive imaging method, the high-frame-rate vector flow imaging technique showed potential value in the preoperative assessment of the symptomatic carotid atherosclerotic stenosis and diagnosing carotid atherosclerotic stenosis in aging patients.


  • Open Access

    Prediction of Pathological Grades of Pancreatic Neuroendocrine Tumors Based on Dynamic Contrast-Enhanced Ultrasound Quantitative Analysis

    by Dao-Hui Yang, Juan Cheng, Xiao-Fan Tian, Qi Zhang, Ling-Yun Yu, Yi-Jie Qiu, Xiu-Yun Lu, Wen-Hui Lou, Yi Dong, Wen-Ping Wang

    Objective: To investigate whether the dynamic contrast-enhanced ultrasound (DCE-US) analysis and quantitative parameters could be helpful for predicting histopathologic grades of pancreatic neuroendocrine tumors (pNETs). Methods: This retrospective study conducted a comprehensive review of the CEUS database between March 2017 and November 2021 in Zhongshan Hospital, Fudan University. Ultrasound examinations were performed by an ACUSON Sequioa unit equipped with a 3.5 MHz 6C−1 convex array transducer, and an ACUSON OXANA2 unit equipped with a 3.5 MHz 5C−1 convex array transducer. SonoVue® (Bracco Inc., Milan, Italy) was used for all CEUS examinations. Time intensity curves (TICs) and quantitative parameters of DCE-US were created by Vuebox® software (Bracco, Italy). Inclusion criteria were: patients with histopathologically proved pNETs, patients who underwent pancreatic B-mode ultrasounds (BMUS) and CEUS scans one week before surgery or biopsy and had DCE-US imaging documented for more than 2 min, patients with solid or predominantly solid lesions and patients with definite diagnosis of histopathological grades of pNETs. Based on their prognosis, patients were categorized into two groups: pNETs G1/G2 group and pNETs G3/pNECs group. Results: A total of 42 patients who underwent surgery (n = 38) or biopsy (n = 4) and had histopathologically confirmed pNETs were included. According to the WHO 2019 criteria, all pNETs were classified into grade 1 (G1, n = 10), grade 2 (G2, n = 21), or grade 3 (G3)/pancreatic neuroendocrine carcinomas (pNECs) (n = 11), based on the Ki−67 proliferation index and the mitotic activity. The majority of the TICs (27/31) of pNETs G1/G2 were above or equal to those of pancreatic parenchyma in the arterial phase, but most (7/11) pNETs G3/pNECs had TICs below those of pancreatic parenchyma from arterial phase to late phase (p < 0.05). Among all the CEUS quantitative parameters of DCE-US, values of relative rise time (rPE), relative mean transit time (rmTT) and relative area under the curve (rAUC) were significantly higher in pNETs G1/G2 group than those in pNETs G3/pNECs group (p < 0.05). Taking an rPE below 1.09 as the optimal cut-off value, the sensitivity, specificity and accuracy for prediction of pNETs G3/pNECs from G1/G2 were 90.91% [58.70% to 99.80%], 67.64% [48.61% to 83.32%] and 85.78% [74.14% to 97.42%], respectively. Taking rAUC below 0.855 as the optimal cut-off value, the sensitivity, specificity and accuracy for prediction of pNETs G3/pNECs from G1/G2 were 90.91% [66.26% to 99.53%], 83.87% [67.37% to 92.91%] and 94.72% [88.30% to 100.00%], respectively. Conclusions: Dynamic contrast-enhanced ultrasound analysis might be helpful for predicting the pathological grades of pNETs. Among all quantitative parameters, rPE, rmTT and rAUC are potentially useful parameters for predicting G3/pNECs with aggressive behavior.