Yiqiu Qi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yiqiu Qi has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jinzhu Yang
College of Computer Science and Engineering, Northeastern University, Shenyang, China
5 shared publications Mingjun Qu
3 shared publicationsHonghe Li
Computer Science and Engineering, Northeastern University, Shenyang, China; Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, China; National Frontiers Science Center for Industrial Intelligence and Systems Optimization, Shenyang, China
2 shared publicationsHongxia Ning
Department of Cardiovascular Ultrasound, The First Hospital of China Medical University, China; Clinical Medical Research Center of Imaging in Liaoning Province, Shenyang, China
2 shared publicationsQi Yu
Computer Science and Engineering, Northeastern University, Shenyang, China; Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, China; National Frontiers Science Center for Industrial Intelligence and Systems Optimization, Shenyang, China
2 shared publications- Qi Yu
Computer Science and Engineering, Northeastern University, Shenyang, China; Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, China; National Frontiers Science Center for Industrial Intelligence and Systems Optimization, Shenyang, China
2 shared publications
Latest Publications
- 17 May 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 329
An apical rocking recognition model based on anatomical prior guidance and spatio-temporal co-modeling
- 17 May 2026
- Published by Elsevier in Expert Systems with Applications
- Vol. 329
An apical rocking recognition model based on anatomical prior guidance and spatio-temporal co-modeling
- 7 July 2025
- Published by Elsevier in Neurocomputing
- Vol. 650
A multi-level contrastive learning-based correction model for semi-supervised fetal echocardiography segmentation
- 7 July 2025
- Published by Elsevier in Neurocomputing
- Vol. 650
A multi-level contrastive learning-based correction model for semi-supervised fetal echocardiography segmentation
- 13 March 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 123, 102525
CQENet: A segmentation model for nasopharyngeal carcinoma based on confidence quantitative evaluation
- 13 March 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 123, 102525
CQENet: A segmentation model for nasopharyngeal carcinoma based on confidence quantitative evaluation
- 5 January 2025
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 160, 103065
ECGEFNet: A two-branch deep learning model for calculating left ventricular ejection fraction using electrocardiogram
- 5 January 2025
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 160, 103065
ECGEFNet: A two-branch deep learning model for calculating left ventricular ejection fraction using electrocardiogram
- 13 December 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 260, 108544
CMR-BENet: A confidence map refinement boundary enhancement network for left ventricular myocardium segmentation
- 13 December 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 260, 108544
CMR-BENet: A confidence map refinement boundary enhancement network for left ventricular myocardium segmentation
- Open Access
- 9 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 543
Soluble Vascular Cell Adhesion Molecule-1 as an Inflammation-Related Biomarker of Coronary Slow Flow
Background: Coronary slow flow (CSF) is an angiographic entity characterized by delayed coronary opacification with no evident obstructive lesion in the epicardial coronary artery. Several studies have shown that the occurrence and development of CSF may be closely related to inflammation. Soluble vascular cell adhesion molecule-1 (sVCAM-1) is a biomarker related to inflammation. The aim of this study was to evaluate the correlation between plasma soluble VCAM-1 level and CSF occurrence and thus the predictive value of VCAM-1 for CSF. Methods: Forty-six CSF patients and thirty control subjects were enrolled. Corrected thrombolysis in myocardial infarction frame count (cTFC) was used to diagnose CSF. Functional status and quality of life were determined by the Seattle Angina Questionnaire (SAQ). Echocardiography was used to evaluate the systolic and diastolic function of the left ventricle (LV) and right ventricle (RV). The plasma levels of sVCAM-1, IL-6, and TNF-α were quantified by enzyme-linked immunosorbent assay. Results: Compared with the control group, the physical limitation score by the SAQ, the LV global longitudinal strain (GLS), mitral E, and mitral E/A decreased in patients with CSF, while the plasma IL-6 and TNF-α levels increased. The plasma sVCAM-1 level in the CSF group was significantly higher than that in the control group (186.03 ± 83.21 vs. 82.43 ± 42.12 ng/mL, p < 0.001), positively correlated with mean cTFC (r = 0.57, p < 0.001), and negatively correlated with the physical limitation score (r = −0.32, p = 0.004). Logistic regression analyses confirmed that plasma sVCAM-1 level (OR = 1.07, 95%CI: 1.03–1.11) is an independent predictor of CSF, and the receiver operating characteristic curve analysis showed that plasma sVCAM-1 levels had statistical significance in predicting CSF (area under curve = 0.88, p < 0.001). When the sVCAM-1 level was higher than 111.57 ng/mL, the sensitivity for predicting CSF was 87% and the specificity was 73%. Conclusions: Plasma sVCAM-1 level can be used to predict CSF and was associated with the clinical symptoms of patients. It may serve as a potential biomarker for CSF in the future.
- 9 January 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (2) , 543
Open AccessSoluble Vascular Cell Adhesion Molecule-1 as an Inflammation-Related Biomarker of Coronary Slow Flow
Background: Coronary slow flow (CSF) is an angiographic entity characterized by delayed coronary opacification with no evident obstructive lesion in the epicardial coronary artery. Several studies have shown that the occurrence and development of CSF may be closely related to inflammation. Soluble vascular cell adhesion molecule-1 (sVCAM-1) is a biomarker related to inflammation. The aim of this study was to evaluate the correlation between plasma soluble VCAM-1 level and CSF occurrence and thus the predictive value of VCAM-1 for CSF. Methods: Forty-six CSF patients and thirty control subjects were enrolled. Corrected thrombolysis in myocardial infarction frame count (cTFC) was used to diagnose CSF. Functional status and quality of life were determined by the Seattle Angina Questionnaire (SAQ). Echocardiography was used to evaluate the systolic and diastolic function of the left ventricle (LV) and right ventricle (RV). The plasma levels of sVCAM-1, IL-6, and TNF-α were quantified by enzyme-linked immunosorbent assay. Results: Compared with the control group, the physical limitation score by the SAQ, the LV global longitudinal strain (GLS), mitral E, and mitral E/A decreased in patients with CSF, while the plasma IL-6 and TNF-α levels increased. The plasma sVCAM-1 level in the CSF group was significantly higher than that in the control group (186.03 ± 83.21 vs. 82.43 ± 42.12 ng/mL, p < 0.001), positively correlated with mean cTFC (r = 0.57, p < 0.001), and negatively correlated with the physical limitation score (r = −0.32, p = 0.004). Logistic regression analyses confirmed that plasma sVCAM-1 level (OR = 1.07, 95%CI: 1.03–1.11) is an independent predictor of CSF, and the receiver operating characteristic curve analysis showed that plasma sVCAM-1 levels had statistical significance in predicting CSF (area under curve = 0.88, p < 0.001). When the sVCAM-1 level was higher than 111.57 ng/mL, the sensitivity for predicting CSF was 87% and the specificity was 73%. Conclusions: Plasma sVCAM-1 level can be used to predict CSF and was associated with the clinical symptoms of patients. It may serve as a potential biomarker for CSF in the future.