Salah Eddine Rezgui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Salah Eddine Rezgui has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Houcine Benalla
University of Constantine 1
5 shared publications - Besma Nemouchi
University Frères Mentouri Constantine 1
2 shared publications - Es-Saadi Terfia
Department of Electrotechnical and Automatic Engineering Laboratory of Electrical Engineering of Guelma (LGEG) Université 8 Mai 1945 24000 Guelma Algeria
2 shared publications - Hamza Gasmi
Université 8 Mai 1945 Guelma
2 shared publications - K. Nebti
University Frères Mentouri Constantine 1
2 shared publications - Sofiane Mendaci
Laboratoire D'Automatique et Informatique de Guelma (LAIG), Department of Electrical Engineering, Université 8 Mai 1945, Guelma, 24000, Algeria
2 shared publications
Latest Publications
- Open Access
- 2 November 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 6,p. 75-83
Nonlinear vector control of multiphase induction motor using linear quadratic regulator and active disturbances rejection control under disturbances and parameter variations
Introduction. This paper introduces a hybrid control strategy for multiphase induction motors, specifically focusing on the dual star induction motor (DSIM) by integrating active disturbances rejection control (ADRC) and linear quadratic regulator (LQR). Problem. Conventional PI-based indirect field oriented control (IFOC) of DSIM drives exhibit 3 critical shortcomings: 1) sensitivity to parameter variations, such as rotor resistance fluctuations; 2) sluggish transient response during rapid speed and torque changes; 3) slow disturbances rejection, such as sudden load torque variations. The goal of this work is to achieve enhanced reliability, precision and robustness of DSIM drives in high-performance demand applications such as automotive. Methodology. The proposed hybrid control architecture is structured as follows: 1) IFOC decoupling. The DSIM’s stator currents are decomposed into 2 components using Park transformations, aligning the rotor flux vector to the d-axis. 2) The LQR is designed to optimize the outer speed/torque loop regulation by minimizing control efforts and state deviations. 3) ADRCs controllers are designed in the inner current loops. Each controller utilizes an extended state observer to estimate and compensate parameter variations and external disturbances in real time. Results. Simulations using MATLAB/Simulink validation on a 5 kW DSIM under multiple scenarios confirm the robustness of the proposed hybrid strategy. Scientific novelty. The contribution lies in the integration of ADRC and LQR in IFOC: The hierarchical fusion of ADRC (inner loops) and LQR (outer loop) uniquely leverages ADRC’s and the LQR’s real-time power to handle any disturbances and unmodeled dynamics. Practical value. The proposed technique demonstrates enhanced performances in speed’s response, sudden load torque demands and parameter variations. It exhibited high robustness even under degraded conditions such as phase faults, making this strategy ideal for high-performance applications like electric vehicles, where stability and adaptability are critical. References 31, tables 2, figures 24.
- 2 November 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 6,p. 75-83
Open AccessNonlinear vector control of multiphase induction motor using linear quadratic regulator and active disturbances rejection control under disturbances and parameter variations
Introduction. This paper introduces a hybrid control strategy for multiphase induction motors, specifically focusing on the dual star induction motor (DSIM) by integrating active disturbances rejection control (ADRC) and linear quadratic regulator (LQR). Problem. Conventional PI-based indirect field oriented control (IFOC) of DSIM drives exhibit 3 critical shortcomings: 1) sensitivity to parameter variations, such as rotor resistance fluctuations; 2) sluggish transient response during rapid speed and torque changes; 3) slow disturbances rejection, such as sudden load torque variations. The goal of this work is to achieve enhanced reliability, precision and robustness of DSIM drives in high-performance demand applications such as automotive. Methodology. The proposed hybrid control architecture is structured as follows: 1) IFOC decoupling. The DSIM’s stator currents are decomposed into 2 components using Park transformations, aligning the rotor flux vector to the d-axis. 2) The LQR is designed to optimize the outer speed/torque loop regulation by minimizing control efforts and state deviations. 3) ADRCs controllers are designed in the inner current loops. Each controller utilizes an extended state observer to estimate and compensate parameter variations and external disturbances in real time. Results. Simulations using MATLAB/Simulink validation on a 5 kW DSIM under multiple scenarios confirm the robustness of the proposed hybrid strategy. Scientific novelty. The contribution lies in the integration of ADRC and LQR in IFOC: The hierarchical fusion of ADRC (inner loops) and LQR (outer loop) uniquely leverages ADRC’s and the LQR’s real-time power to handle any disturbances and unmodeled dynamics. Practical value. The proposed technique demonstrates enhanced performances in speed’s response, sudden load torque demands and parameter variations. It exhibited high robustness even under degraded conditions such as phase faults, making this strategy ideal for high-performance applications like electric vehicles, where stability and adaptability are critical. References 31, tables 2, figures 24.
- Open Access
- 2 March 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 24-30
Ensuring service continuity in electric vehicles with vector control and linear quadratic regulator for dual star induction motors
Introduction. In this paper, the use of a Linear Quadratic Regulator (LQR) to control a Dual Star Induction Motor (DSIM) powered by dual three-level neutral point clamped inverters in electric vehicle (EV) propulsion systems is explored. Purpose. Ensuring both high performance against parameter sensitivity and service continuity in the event of faults is challenging in EV propulsion systems. The aim is to maximize both system performance and service continuity through the optimal design of the controller. Methods. DSIM is controlled by a LQR, which is replaced the traditional PI controller in the field-oriented control (FOC) system for speed regulation. Starting with FOC the optimal regulator is designed by introducing a minimization criterion into the Ricatti equation. The LQR control law is then employed as a speed regulator to ensure precise regulation and optimize DSIM operation under various load and speed conditions. The avoidance of linearization of the DSIM facilitates the exploitation of its true nonlinear dynamics. Novelty. Three tests are conducted to evaluate system performance. A precision test by varying the reference speed and analyzing speed response, settling time, precision and overshoot, a robustness test against parameter variations, assessing system robustness against changes in stator and rotor resistances and moment of inertia, and a fault robustness test evaluating system robustness against faults such as phase faults while maintaining load torque. The results show that this approach can keep the motor running smoothly even under parameter variations or degraded conditions. The precision and adaptability of the LQR technique enhance the overall efficiency and stability of the DSIM, making it a highly viable solution for modern EVs. This robust performance against parameter variations and loads is essential in ensuring the reliability and longevity of EV propulsion systems. Practical value. This approach holds significant potential for advancing EV technology, promising improved performance and reliability in real-world applications. References 44, tables 2, figures 15.
- 2 March 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 24-30
Open AccessEnsuring service continuity in electric vehicles with vector control and linear quadratic regulator for dual star induction motors
Introduction. In this paper, the use of a Linear Quadratic Regulator (LQR) to control a Dual Star Induction Motor (DSIM) powered by dual three-level neutral point clamped inverters in electric vehicle (EV) propulsion systems is explored. Purpose. Ensuring both high performance against parameter sensitivity and service continuity in the event of faults is challenging in EV propulsion systems. The aim is to maximize both system performance and service continuity through the optimal design of the controller. Methods. DSIM is controlled by a LQR, which is replaced the traditional PI controller in the field-oriented control (FOC) system for speed regulation. Starting with FOC the optimal regulator is designed by introducing a minimization criterion into the Ricatti equation. The LQR control law is then employed as a speed regulator to ensure precise regulation and optimize DSIM operation under various load and speed conditions. The avoidance of linearization of the DSIM facilitates the exploitation of its true nonlinear dynamics. Novelty. Three tests are conducted to evaluate system performance. A precision test by varying the reference speed and analyzing speed response, settling time, precision and overshoot, a robustness test against parameter variations, assessing system robustness against changes in stator and rotor resistances and moment of inertia, and a fault robustness test evaluating system robustness against faults such as phase faults while maintaining load torque. The results show that this approach can keep the motor running smoothly even under parameter variations or degraded conditions. The precision and adaptability of the LQR technique enhance the overall efficiency and stability of the DSIM, making it a highly viable solution for modern EVs. This robust performance against parameter variations and loads is essential in ensuring the reliability and longevity of EV propulsion systems. Practical value. This approach holds significant potential for advancing EV technology, promising improved performance and reliability in real-world applications. References 44, tables 2, figures 15.
- Open Access
- 19 August 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 14-19
Fractional-based iterative learning-optimal model predictive control of speed induction motor regulation for electric vehicles application
Introduction. A new control strategy based on the combination of optimal model predictive control (OMPC) with fractional iterative learning control (F-ILC) for speed regulation of an induction motor (IM) for electric vehicles (EVs) application is presented. OMPC uses predictive models to optimize speed control actions by considering the dynamic behavior of the IM, when integrated with the F-ILC, the system learns and refines the speed control iteratively based on previous iterations, adapting to the specific characteristics of the IM and improving performance over time. The synergy between OMPC and F-ILC named F-ILC-OMPC enhances the precision and adaptability of speed control for IMs in EVs application, and optimizes the energy efficiency and responsiveness under varying driving conditions. The novelty lies in the conjunction of the OMPC with the ILC-based on the fractional calculus to regulate the speed of IMs, which is original. Purpose. The new control strategy provides increased performance, robustness and adaptability to changing operational conditions. Methods. The mathematical development of a control law that mitigates the disturbance and achieves accurate and efficient speed regulation. The effectiveness of the suggested control strategy was assessed via simulations in MATLAB conducted on an IM system. Results. The results clearly show the benefits of the F-ILC-OMPC methodology in attaining accurate speed control, minimizing steady-state error and enhanced disturbance rejection. Practical value. The main perspective lies in the development of a speed control strategy for IMs for EVs and the establishment of reliable and efficient electrical systems using ILC-OMPC control. This research has the prospect of a subsequent implementation of these results in experimental prototypes. References 24, tables 2, figures 9.
- 19 August 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 14-19
Open AccessFractional-based iterative learning-optimal model predictive control of speed induction motor regulation for electric vehicles application
Introduction. A new control strategy based on the combination of optimal model predictive control (OMPC) with fractional iterative learning control (F-ILC) for speed regulation of an induction motor (IM) for electric vehicles (EVs) application is presented. OMPC uses predictive models to optimize speed control actions by considering the dynamic behavior of the IM, when integrated with the F-ILC, the system learns and refines the speed control iteratively based on previous iterations, adapting to the specific characteristics of the IM and improving performance over time. The synergy between OMPC and F-ILC named F-ILC-OMPC enhances the precision and adaptability of speed control for IMs in EVs application, and optimizes the energy efficiency and responsiveness under varying driving conditions. The novelty lies in the conjunction of the OMPC with the ILC-based on the fractional calculus to regulate the speed of IMs, which is original. Purpose. The new control strategy provides increased performance, robustness and adaptability to changing operational conditions. Methods. The mathematical development of a control law that mitigates the disturbance and achieves accurate and efficient speed regulation. The effectiveness of the suggested control strategy was assessed via simulations in MATLAB conducted on an IM system. Results. The results clearly show the benefits of the F-ILC-OMPC methodology in attaining accurate speed control, minimizing steady-state error and enhanced disturbance rejection. Practical value. The main perspective lies in the development of a speed control strategy for IMs for EVs and the establishment of reliable and efficient electrical systems using ILC-OMPC control. This research has the prospect of a subsequent implementation of these results in experimental prototypes. References 24, tables 2, figures 9.
- Open Access
- 15 March 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (8) , 1576-1589
Driving an asynchronous motor powered by PV‐MPPT using equivalent RST controller of fractional order PI and IP, based on generalized predictive control
The article introduces a new model of a Reference Signal Tracking (RST) controller for the fractional order quantities. The controller is applied to an indirect field‐oriented control (IFOC) system used for the speed control of an asynchronous motor powered by a photovoltaic (PV) generator with a maximum power point tracking (MPPT) algorithm. This model utilizes two fractional order controllers: the fractional order proportional‐integral (FOPI) regulator and the fractional‐order integral‐proportional (FOIP) regulator. These controllers are used with the generalized predictive control (GPC) technique. The first step in the approach is to derive the equivalent digital RST controller's model from the FOPI and FOIP controller's transfer functions. The GPC technique converts the continuous‐time FOPI (and FOIP) controller into a discrete‐time version. This conversion ensures a fast response and effective disturbance rejection. Simulation tests are conducted to analyze the rotor speed and stator current ripples to evaluate the performance of the proposed method. The results demonstrate the effectiveness of the introduced scheme in achieving improved control performance in terms of response speed and disturbance rejection. The article presents a modified RST controller model based on the fractional order approach applied to an IFOC system for motor speed control driven by a photovoltaic generator. Using FOPI, FOIP controllers, and GPC contributes to enhanced control performance, as evidenced by the simulation results.
- 15 March 2024
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 18 (8) , 1576-1589
Open AccessDriving an asynchronous motor powered by PV‐MPPT using equivalent RST controller of fractional order PI and IP, based on generalized predictive control
The article introduces a new model of a Reference Signal Tracking (RST) controller for the fractional order quantities. The controller is applied to an indirect field‐oriented control (IFOC) system used for the speed control of an asynchronous motor powered by a photovoltaic (PV) generator with a maximum power point tracking (MPPT) algorithm. This model utilizes two fractional order controllers: the fractional order proportional‐integral (FOPI) regulator and the fractional‐order integral‐proportional (FOIP) regulator. These controllers are used with the generalized predictive control (GPC) technique. The first step in the approach is to derive the equivalent digital RST controller's model from the FOPI and FOIP controller's transfer functions. The GPC technique converts the continuous‐time FOPI (and FOIP) controller into a discrete‐time version. This conversion ensures a fast response and effective disturbance rejection. Simulation tests are conducted to analyze the rotor speed and stator current ripples to evaluate the performance of the proposed method. The results demonstrate the effectiveness of the introduced scheme in achieving improved control performance in terms of response speed and disturbance rejection. The article presents a modified RST controller model based on the fractional order approach applied to an IFOC system for motor speed control driven by a photovoltaic generator. Using FOPI, FOIP controllers, and GPC contributes to enhanced control performance, as evidenced by the simulation results.
- Open Access
- 31 December 2023
- Published by Acadlore Publishing Services Limited in Journal of Intelligent Systems and Control
- Vol. 2 (4) , 220-229
Enhanced Control of Dual Star Induction Motor via Super Twisting Algorithm: A Comparative Analysis with Classical PI Controllers
In the field of industrial motor control, the inherent design complexity and operational challenge of dual star induction motor (DSIM) have made it a focus of research for many scholars. This study attempts to innovatively propose a refined control approach for DSIM, by deploying two pulse width modulation (PWM) voltage sources combining with indirect field-oriented control (IFOC). Core of our innovation is the integration of a super twisting algorithm (STA) controller, which is a strategy specifically designed to enhance the motor's speed control capability. The paper introduced the technical details of DSIM, with the focus placed on the distinctive configuration of two isolated neutral three-phase windings, set apart by a 30-degree electrical phase shift. Such design has posed certain control challenges, and the STA approach has skillfully addressed these challenges. With the help of Matlab/Simulink simulations, the efficacy of STA controller is evaluated and compared with the common Proportional-Integral (PI) controller, and the simulation results are indicative of the STA controller's superiority, showing a significant improvement in reducing torque ripples and stator current fluctuations. The analysis given in the paper quantifies the improvement, showing substantial reductions in steady-state error and response time, as well as an enhanced disturbance rejection capability. These findings are instrumental in showcasing the STA controller's comparative advantage. Concludingly, the adoption of the STA-based control methodology in DSIM applications not only fosters enhanced speed control and efficiency but also holds the promise of broad applicability across various industrial scenarios. This research, therefore, marks a pivotal advancement in the field of DSIM control, potentially revolutionizing its application in diverse industrial settings. The consistency in the use of professional terminology throughout the paper ensures a coherent and comprehensive understanding of the subject matter.
- 31 December 2023
- Published by Acadlore Publishing Services Limited in Journal of Intelligent Systems and Control
- Vol. 2 (4) , 220-229
Open AccessEnhanced Control of Dual Star Induction Motor via Super Twisting Algorithm: A Comparative Analysis with Classical PI Controllers
In the field of industrial motor control, the inherent design complexity and operational challenge of dual star induction motor (DSIM) have made it a focus of research for many scholars. This study attempts to innovatively propose a refined control approach for DSIM, by deploying two pulse width modulation (PWM) voltage sources combining with indirect field-oriented control (IFOC). Core of our innovation is the integration of a super twisting algorithm (STA) controller, which is a strategy specifically designed to enhance the motor's speed control capability. The paper introduced the technical details of DSIM, with the focus placed on the distinctive configuration of two isolated neutral three-phase windings, set apart by a 30-degree electrical phase shift. Such design has posed certain control challenges, and the STA approach has skillfully addressed these challenges. With the help of Matlab/Simulink simulations, the efficacy of STA controller is evaluated and compared with the common Proportional-Integral (PI) controller, and the simulation results are indicative of the STA controller's superiority, showing a significant improvement in reducing torque ripples and stator current fluctuations. The analysis given in the paper quantifies the improvement, showing substantial reductions in steady-state error and response time, as well as an enhanced disturbance rejection capability. These findings are instrumental in showcasing the STA controller's comparative advantage. Concludingly, the adoption of the STA-based control methodology in DSIM applications not only fosters enhanced speed control and efficiency but also holds the promise of broad applicability across various industrial scenarios. This research, therefore, marks a pivotal advancement in the field of DSIM control, potentially revolutionizing its application in diverse industrial settings. The consistency in the use of professional terminology throughout the paper ensures a coherent and comprehensive understanding of the subject matter.
- Open Access
- 4 January 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 20-24
Power quality enhancement using active power filter five-level cascade H-bridge under unbalanced and distorted grid
Introduction. To improve the power quality of a supply system, the total harmonic distortion (THD) is the most important parameter in the quantification of harmonics caused by nonlinear loads. In practice, it must be less than 5 %. The novelty of the proposed work consists in the use of a cascaded five level active filter, when the converter consisting of six H-bridge pairs, each one includes four transistors. Purpose. To increase the efficiency of this filter, two techniques for quantification of harmonic currents are proposed, first the PQ-theory which is simple but can only be used in case of a balanced grid, and second the synchronous reference frame theory (SFR-theory), which is capable of creating harmonic current not only in an unbalanced grid, but also in an unbalanced and distorted beam. Methods. Using the control techniques, the harmonic current is extracted from load current and considered as a reference. The constructed current should follow this reference. Results. The estimation of the active and reactive powers is based on the measurement of the currents crossing the load and the network voltages, these powers are used to determine the shape of the harmonic (reference) current. Using the PI regulator, the output current of the five-level inverter follows the reference current perfectly. The inverters output current is injected into the grid to eliminate harmonic currents. Practical value. In practice, the harmonic distortion rate THD is the most widely used criterion for criticizing the waveform of the currents and judging the quality of the energy involved. For currents on the source side, the THD is considered acceptable if it is less than 5 %, in our proposal the THD is 0.85 % with the PQ-theory and 2.34 % with SFR-theory, so it is optimal.
- 4 January 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 20-24
Open AccessPower quality enhancement using active power filter five-level cascade H-bridge under unbalanced and distorted grid
Introduction. To improve the power quality of a supply system, the total harmonic distortion (THD) is the most important parameter in the quantification of harmonics caused by nonlinear loads. In practice, it must be less than 5 %. The novelty of the proposed work consists in the use of a cascaded five level active filter, when the converter consisting of six H-bridge pairs, each one includes four transistors. Purpose. To increase the efficiency of this filter, two techniques for quantification of harmonic currents are proposed, first the PQ-theory which is simple but can only be used in case of a balanced grid, and second the synchronous reference frame theory (SFR-theory), which is capable of creating harmonic current not only in an unbalanced grid, but also in an unbalanced and distorted beam. Methods. Using the control techniques, the harmonic current is extracted from load current and considered as a reference. The constructed current should follow this reference. Results. The estimation of the active and reactive powers is based on the measurement of the currents crossing the load and the network voltages, these powers are used to determine the shape of the harmonic (reference) current. Using the PI regulator, the output current of the five-level inverter follows the reference current perfectly. The inverters output current is injected into the grid to eliminate harmonic currents. Practical value. In practice, the harmonic distortion rate THD is the most widely used criterion for criticizing the waveform of the currents and judging the quality of the energy involved. For currents on the source side, the THD is considered acceptable if it is less than 5 %, in our proposal the THD is 0.85 % with the PQ-theory and 2.34 % with SFR-theory, so it is optimal.
- 18 December 2020
- Published by Springer Nature
- p. 222-232
Performance Improvement of IFOC Based on Particle Swarm Optimization Algorithm in Induction Motor Control
- 18 December 2020
- Published by Springer Nature
- p. 222-232
Performance Improvement of IFOC Based on Particle Swarm Optimization Algorithm in Induction Motor Control