Minsha Shah
Research Subjects
Minsha Shah has a total of 81 co-authors. Here are the top co-authors by number of shared publications:
Rachana Rajpal
3 shared publications- Prabal K. Chattopadhyay
Institute for Plasma Research, HBNI 1 , Bhat, Gandhinagar 382428
2 shared publications - Praveenlal Edappala
Institute for Plasma Research, Gandhinagar, India
2 shared publications - Rakesh L. Tanna
Institute for Plasma Research
2 shared publications Abha Kanik
1 shared publicationAbhijeet Kumar
1 shared publication
Latest Publications
- 6 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 233
Laser heated emissive probe (LHEP) for plasma potential measurement in the ADITYA-U tokamak
- 6 October 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 233
Laser heated emissive probe (LHEP) for plasma potential measurement in the ADITYA-U tokamak
- 21 March 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 227
Electronics, data acquisition and control systems for ADITYA-U Tokamak
- 21 March 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 227
Electronics, data acquisition and control systems for ADITYA-U Tokamak
- Open Access
- 1 August 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (8)
Charge measurement diagnostics with improved SNR and bit utilization for electron plasma confined in a partial toroidal trap
The SMall Aspect Ratio Toroidal EXperiment in a C-shaped torus recently reported an unprecedented electron plasma confinement, τconfine, of >100s. Understanding the plasma transport mechanism is essential to validate the observed long confinement. Measurement of the total charge Qtotal and its spatial and temporal evolution offers insight into the plasma transport mechanism. The existing charge collector for measuring Qtotal is affected by fast transients, resulting in a low signal-to-noise ratio (SNR) and insufficient bit resolution, which makes its measurement difficult, especially at long confinement times. This restricted the measurement of Qtotal only to about 20 ms. The upgraded charge collector has modified switching circuitry and has utilized components that are carefully considered to mitigate the effect of transients. The resulting increase in SNR and improvement in bit resolution have thereby allowed measurement of Qtotal for extended confinement periods of up to 30 s.
- 1 August 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (8)
Open AccessCharge measurement diagnostics with improved SNR and bit utilization for electron plasma confined in a partial toroidal trap
The SMall Aspect Ratio Toroidal EXperiment in a C-shaped torus recently reported an unprecedented electron plasma confinement, τconfine, of >100s. Understanding the plasma transport mechanism is essential to validate the observed long confinement. Measurement of the total charge Qtotal and its spatial and temporal evolution offers insight into the plasma transport mechanism. The existing charge collector for measuring Qtotal is affected by fast transients, resulting in a low signal-to-noise ratio (SNR) and insufficient bit resolution, which makes its measurement difficult, especially at long confinement times. This restricted the measurement of Qtotal only to about 20 ms. The upgraded charge collector has modified switching circuitry and has utilized components that are carefully considered to mitigate the effect of transients. The resulting increase in SNR and improvement in bit resolution have thereby allowed measurement of Qtotal for extended confinement periods of up to 30 s.
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-6
A Simple Device for Simultaneous Measurement of Stokes Polarization Parameters
This paper presents a simple Polarization Measuring Device (PMD) developed indigenously for the simultaneous measurement of Stokes polarization parameters. Most of standard Stokes parameters measuring techniques, particularly the one which uses wave retarder and linear polarizer, require at least half a rotation of either of polarization elements. Therefore, they cannot provide simultaneous measurement of Stokes parameters. Consequently, the time resolution of measurement is limited by rotation period of polarization optics and the functionality of measuring setup is limited to beams with constant polarization state. In this work, a new device has been presented which is capable of providing simultaneous measurement of beam intensities for both the constant as well as the time varying State of Polarization (SOP). It enables the estimation of first three Stokes parameters through four intensity measurements I (0°), I (90°), I (45°) and I (-45°). The functionality of PMD has been verified on a test bench by using various known polarization states and comparing the results with measurements made using a rotating linear polarizer/analyzer (RA). For each case, the parameters of polarization ellipse are deduced from the measured Stokes parameters. In addition to that, the corresponding polarization ellipses are constructed from the retrieved ellipse parameters. The ellipse parameters measured by PMD are compared with that measured using RA and the ellipses drawn from the PMD measurements are overlapped with that obtained using RA. The measurements made by RA are the reference measurements for finding the efficiency of PMD. The measurement accuracy of PMD is found to be ≤0.01 for values of axes a and b and it is ≤0.5° for orientation angle Ψ of polarization ellipse. As the accuracy of measurement is comparable to other polarization measuring instruments/setups, any optical arrangement for which measurement is polarization sensitive can use PMD for finding SOP. The main advantage of the PMD is it can measure all requisite parameters of polarization ellipse, which is the most useful presentation of any polarization state, and is capable of dealing with both the constant and time varying SOP.
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-6
A Simple Device for Simultaneous Measurement of Stokes Polarization Parameters
This paper presents a simple Polarization Measuring Device (PMD) developed indigenously for the simultaneous measurement of Stokes polarization parameters. Most of standard Stokes parameters measuring techniques, particularly the one which uses wave retarder and linear polarizer, require at least half a rotation of either of polarization elements. Therefore, they cannot provide simultaneous measurement of Stokes parameters. Consequently, the time resolution of measurement is limited by rotation period of polarization optics and the functionality of measuring setup is limited to beams with constant polarization state. In this work, a new device has been presented which is capable of providing simultaneous measurement of beam intensities for both the constant as well as the time varying State of Polarization (SOP). It enables the estimation of first three Stokes parameters through four intensity measurements I (0°), I (90°), I (45°) and I (-45°). The functionality of PMD has been verified on a test bench by using various known polarization states and comparing the results with measurements made using a rotating linear polarizer/analyzer (RA). For each case, the parameters of polarization ellipse are deduced from the measured Stokes parameters. In addition to that, the corresponding polarization ellipses are constructed from the retrieved ellipse parameters. The ellipse parameters measured by PMD are compared with that measured using RA and the ellipses drawn from the PMD measurements are overlapped with that obtained using RA. The measurements made by RA are the reference measurements for finding the efficiency of PMD. The measurement accuracy of PMD is found to be ≤0.01 for values of axes a and b and it is ≤0.5° for orientation angle Ψ of polarization ellipse. As the accuracy of measurement is comparable to other polarization measuring instruments/setups, any optical arrangement for which measurement is polarization sensitive can use PMD for finding SOP. The main advantage of the PMD is it can measure all requisite parameters of polarization ellipse, which is the most useful presentation of any polarization state, and is capable of dealing with both the constant and time varying SOP.
- 21 June 2019
- Published by IOP Publishing in Nuclear Fusion
- Vol. 59 (8) , 086005
Novel approach of pulsed-glow discharge wall conditioning in the ADITYA Upgrade tokamak
- 21 June 2019
- Published by IOP Publishing in Nuclear Fusion
- Vol. 59 (8) , 086005
Novel approach of pulsed-glow discharge wall conditioning in the ADITYA Upgrade tokamak