Talal Ali Ahmed Abdullah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Talal Ali Ahmed Abdullah has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Mohd Soperi Mohd Zahid
Department of Computing, Universiti Teknologi PETRONAS, Seri Iskandar 32610, Malaysia
5 shared publications - Waleed Ali
Information Technology Department, Faculty of Computing and Information Technology-Rabigh, King Abdulaziz University, Jeddah 25729, Saudi Arabia
5 shared publications - Adel Ali Abdullah
Information Technology Department, Faculty of Computing and Information Technology-Rabigh, King Abdulaziz University, Jeddah 25729, Saudi Arabia
3 shared publications Waleed Ali
King Abdulaziz University
2 shared publicationsAbdelzahir Abdelmaboud
Humanities Research Center, Sultan Qaboos University, Seeb, Oman
1 shared publication- Abdussalam Ahmed Alashhab
Department of Computer Science, Faculty of Information Technology, Alasmarya Islamic University, Zliten, Libya
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 1 May 2026
- Published by MDPI AG in Technologies
- Vol. 14 (5) , 274
An Enhanced XGBoost-Based Framework for Efficient Multi-Class Cyber Threat Detection in Industrial IoT Networks
Securing Industrial IoT (IIoT) network environments remains a significant challenge due to the increasing complexity of interconnected sensors, actuators, gateways, and control systems, which are frequent targets of cyberattacks. These threats can lead to operational disruptions, financial losses, and safety risks. This paper proposes an efficient multi-stage intrusion detection framework based on an enhanced Extreme Gradient Boosting (XGBoost) model for IIoT environments. The proposed framework integrates data preprocessing, class imbalance handling, hyperparameter optimization, probability calibration, and class-specific decision thresholds within a unified pipeline. In addition, calibrated probability outputs are utilized as continuous indicators of prediction confidence, enabling more reliable and risk-aware decision-making. The hierarchical multi-stage design decomposes the detection task into progressively refined classification levels, improving discrimination among complex and overlapping attack categories. The framework is evaluated using the Edge-IIoTset benchmark dataset, which reflects realistic IIoT network traffic under both normal and malicious conditions. Experimental results demonstrate that the proposed approach achieved significant performance improvements, including up to 21% increase in recall and 15% improvement in macro F1 score compared to the baseline models. Furthermore, the model exhibits low inference latency and supports efficient deployment in time-sensitive IIoT monitoring scenarios. These results indicate that the proposed framework provides an effective and scalable solution for multi-class cyber threat detection in IIoT networks.
- 1 May 2026
- Published by MDPI AG in Technologies
- Vol. 14 (5) , 274
Top Cited PapersOpen AccessAn Enhanced XGBoost-Based Framework for Efficient Multi-Class Cyber Threat Detection in Industrial IoT Networks
Securing Industrial IoT (IIoT) network environments remains a significant challenge due to the increasing complexity of interconnected sensors, actuators, gateways, and control systems, which are frequent targets of cyberattacks. These threats can lead to operational disruptions, financial losses, and safety risks. This paper proposes an efficient multi-stage intrusion detection framework based on an enhanced Extreme Gradient Boosting (XGBoost) model for IIoT environments. The proposed framework integrates data preprocessing, class imbalance handling, hyperparameter optimization, probability calibration, and class-specific decision thresholds within a unified pipeline. In addition, calibrated probability outputs are utilized as continuous indicators of prediction confidence, enabling more reliable and risk-aware decision-making. The hierarchical multi-stage design decomposes the detection task into progressively refined classification levels, improving discrimination among complex and overlapping attack categories. The framework is evaluated using the Edge-IIoTset benchmark dataset, which reflects realistic IIoT network traffic under both normal and malicious conditions. Experimental results demonstrate that the proposed approach achieved significant performance improvements, including up to 21% increase in recall and 15% improvement in macro F1 score compared to the baseline models. Furthermore, the model exhibits low inference latency and supports efficient deployment in time-sensitive IIoT monitoring scenarios. These results indicate that the proposed framework provides an effective and scalable solution for multi-class cyber threat detection in IIoT networks.
- Open Access
- 3 March 2026
- Published by MDPI AG in Information
- Vol. 17 (3) , 251
Electrical Power Prediction Using RS-485 Power Meter: A PSO-Optimized XGBoost Approach for Industrial Smart Manufacturing
Accurate electrical power prediction is increasingly critical in industrial smart manufacturing environments, where energy fluctuations and demand variability pose significant operational challenges under the industry 4.0 paradigm. Existing approaches often rely on simulated or secondary data and lack integration with industrial-grade communication protocols, limiting their practical applicability. Incorporating machine learning with real-time data collection is essential for progressing industrial predictive monitoring. This research presents a framework to forecast electrical power usage by utilizing the RS-485 protocol to enhance smart manufacturing processes. The dataset used was obtained from a power meter, recorded over a period of 135 min, resulting in 3100 data. Three learning methods—Random Forest, Extra Trees, and XGBoost—were analyzed, with XGBoost being further refined through PSO for tuning hyperparameters. The models were trained on datasets that included voltage, current, frequency, and power factor, and their effectiveness was evaluated using time-based predictions, standard metrics, and error distributions through cross-validation. The findings illustrate that the PSO-XGBoost consistently surpasses the default XGBoost baseline R2 of 0.5746, achieving MAE of 0.14 W, RMSE of 0.21 W, and R2 of 0.8355, representing improvements of 41.67% in MAE, 38.24% in RMSE, and 45.40% in R2. The RS-485 protocol enables seamless integration with existing industrial infrastructure, supporting anomaly detection and energy optimization aligned with Industry 4.0 interoperability objectives.
- 3 March 2026
- Published by MDPI AG in Information
- Vol. 17 (3) , 251
Open AccessElectrical Power Prediction Using RS-485 Power Meter: A PSO-Optimized XGBoost Approach for Industrial Smart Manufacturing
Accurate electrical power prediction is increasingly critical in industrial smart manufacturing environments, where energy fluctuations and demand variability pose significant operational challenges under the industry 4.0 paradigm. Existing approaches often rely on simulated or secondary data and lack integration with industrial-grade communication protocols, limiting their practical applicability. Incorporating machine learning with real-time data collection is essential for progressing industrial predictive monitoring. This research presents a framework to forecast electrical power usage by utilizing the RS-485 protocol to enhance smart manufacturing processes. The dataset used was obtained from a power meter, recorded over a period of 135 min, resulting in 3100 data. Three learning methods—Random Forest, Extra Trees, and XGBoost—were analyzed, with XGBoost being further refined through PSO for tuning hyperparameters. The models were trained on datasets that included voltage, current, frequency, and power factor, and their effectiveness was evaluated using time-based predictions, standard metrics, and error distributions through cross-validation. The findings illustrate that the PSO-XGBoost consistently surpasses the default XGBoost baseline R2 of 0.5746, achieving MAE of 0.14 W, RMSE of 0.21 W, and R2 of 0.8355, representing improvements of 41.67% in MAE, 38.24% in RMSE, and 45.40% in R2. The RS-485 protocol enables seamless integration with existing industrial infrastructure, supporting anomaly detection and energy optimization aligned with Industry 4.0 interoperability objectives.
- Open Access
An Interpretable Model for Cardiac Arrhythmia Classification Using 1D CNN-GRU with Attention Mechanism
Accurate classification of cardiac arrhythmias remains a crucial task in biomedical signal processing. This study proposes a hybrid deep learning approach called 1D CNN-eGRU that integrates one-dimensional convolutional neural network models (1D CNN) and a gated recurrent unit (GRU) architecture with an attention mechanism for the precise classification of cardiac arrhythmias based on ECG Lead II signals. To enhance the classification of cardiac arrhythmias, we also address data imbalances in the MIT-BIH arrhythmia dataset by introducing a hybrid data balancing method that blends resampling and class-weight learning. Additionally, we apply Sig-LIME, a refined variant of LIME tailored for signal datasets, to provide comprehensive insights into model decisions. The suggested hybrid 1D CNN-eGRU approach, a fusion of 1D CNN-GRU along with an attention mechanism, is designed to acquire intricate temporal and spatial dependencies in ECG signals. It aims to distinguish between four distinct arrhythmia classes from the MIT-BIH dataset, addressing a significant challenge in medical diagnostics. Demonstrating strong performance, the proposed hybrid 1D CNN-eGRU model achieves an overall accuracy of 0.99, sensitivity of 0.93, and specificity of 0.99. Per-class evaluation shows precision ranging from 0.80 to 1.00, sensitivity from 0.83 to 0.99, and F1-scores between 0.82 and 0.99 across four arrhythmia types (normal, supraventricular, ventricular, and fusion). The model also attains an AUC of 1.00 on average, with a final test loss of 0.07. These results not only demonstrate the model’s effectiveness in arrhythmia classification but also underscore the added value of interpretability enabled through the use of the Sig-LIME technique.
Open AccessAn Interpretable Model for Cardiac Arrhythmia Classification Using 1D CNN-GRU with Attention Mechanism
Accurate classification of cardiac arrhythmias remains a crucial task in biomedical signal processing. This study proposes a hybrid deep learning approach called 1D CNN-eGRU that integrates one-dimensional convolutional neural network models (1D CNN) and a gated recurrent unit (GRU) architecture with an attention mechanism for the precise classification of cardiac arrhythmias based on ECG Lead II signals. To enhance the classification of cardiac arrhythmias, we also address data imbalances in the MIT-BIH arrhythmia dataset by introducing a hybrid data balancing method that blends resampling and class-weight learning. Additionally, we apply Sig-LIME, a refined variant of LIME tailored for signal datasets, to provide comprehensive insights into model decisions. The suggested hybrid 1D CNN-eGRU approach, a fusion of 1D CNN-GRU along with an attention mechanism, is designed to acquire intricate temporal and spatial dependencies in ECG signals. It aims to distinguish between four distinct arrhythmia classes from the MIT-BIH dataset, addressing a significant challenge in medical diagnostics. Demonstrating strong performance, the proposed hybrid 1D CNN-eGRU model achieves an overall accuracy of 0.99, sensitivity of 0.93, and specificity of 0.99. Per-class evaluation shows precision ranging from 0.80 to 1.00, sensitivity from 0.83 to 0.99, and F1-scores between 0.82 and 0.99 across four arrhythmia types (normal, supraventricular, ventricular, and fusion). The model also attains an AUC of 1.00 on average, with a final test loss of 0.07. These results not only demonstrate the model’s effectiveness in arrhythmia classification but also underscore the added value of interpretability enabled through the use of the Sig-LIME technique.
- 26 July 2025
- Published by Springer Nature
- p. 343-356
Enhancing Accuracy of 1D CNN-GRU Model for Cardiac Arrhythmia Classification Using Class Weights and Resampling Techniques
- 26 July 2025
- Published by Springer Nature
- p. 343-356
Enhancing Accuracy of 1D CNN-GRU Model for Cardiac Arrhythmia Classification Using Class Weights and Resampling Techniques
- Open Access
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 52641-52658
Sig-Lime: A Signal-Based Enhancement of Lime Explanation Technique
Interpreting machine learning models is facilitated by the widely employed locally interpretable model-agnostic explanation (LIME) technique. However, when extending LIME to signal data, its credibility falters due to perturbation techniques used to generate local datasets. These techniques disrupt temporal dependencies among features, leading to unrealistic data points and potentially misleading explanations. Additionally, LIME faces instability and local fidelity issues, limiting its suitability for real-world applications. The absence of a dedicated LIME package tailored for interpreting signal data further diminishes comprehensibility, especially when applied to models trained on such data. In this paper, we introduce Signal-based LIME (Sig-LIME) to address these limitations. Sig-LIME leverages a novel data generation technique that captures temporal dependence among features, enhancing credibility and stability. It combines a random forest model and heatmaps to provide illuminating explanations for predictions drawn from electrocardiogram (ECG) signals, improving model transparency. Empirical findings underscore the enhanced interpretability and comprehension of model predictions attained by Sig-LIME compared to baseline LIME. Our quantitative evaluation based on an analysis of variance (ANOVA) framework, reveals a notable improvement in stability with Sig-LIME, evidenced by an f-statistic of 0.0 and p-values of 1, indicating a complete absence of variation between multiple runs. Regarding local fidelity, Sig-LIME surpasses the baseline LIME, exhibiting a lower average Euclidean distance of 0.49 compared to 17.24. Sig-LIME excels in generating data more akin to the original, achieving remarkable stability and significantly enhancing credibility and local fidelity in the explanations it generates.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 52641-52658
Open AccessSig-Lime: A Signal-Based Enhancement of Lime Explanation Technique
Interpreting machine learning models is facilitated by the widely employed locally interpretable model-agnostic explanation (LIME) technique. However, when extending LIME to signal data, its credibility falters due to perturbation techniques used to generate local datasets. These techniques disrupt temporal dependencies among features, leading to unrealistic data points and potentially misleading explanations. Additionally, LIME faces instability and local fidelity issues, limiting its suitability for real-world applications. The absence of a dedicated LIME package tailored for interpreting signal data further diminishes comprehensibility, especially when applied to models trained on such data. In this paper, we introduce Signal-based LIME (Sig-LIME) to address these limitations. Sig-LIME leverages a novel data generation technique that captures temporal dependence among features, enhancing credibility and stability. It combines a random forest model and heatmaps to provide illuminating explanations for predictions drawn from electrocardiogram (ECG) signals, improving model transparency. Empirical findings underscore the enhanced interpretability and comprehension of model predictions attained by Sig-LIME compared to baseline LIME. Our quantitative evaluation based on an analysis of variance (ANOVA) framework, reveals a notable improvement in stability with Sig-LIME, evidenced by an f-statistic of 0.0 and p-values of 1, indicating a complete absence of variation between multiple runs. Regarding local fidelity, Sig-LIME surpasses the baseline LIME, exhibiting a lower average Euclidean distance of 0.49 compared to 17.24. Sig-LIME excels in generating data more akin to the original, achieving remarkable stability and significantly enhancing credibility and local fidelity in the explanations it generates.
- Top Cited PapersOpen Access
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 51630-51649
Enhancing DDoS Attack Detection and Mitigation in SDN Using an Ensemble Online Machine Learning Model
Software Defined Networks (SDN) offer dynamic reconfigurability and scalability, revolutionizing traditional networking. However, countering Distributed Denial of Service (DDoS) attacks remains a formidable challenge for both traditional and SDN-based networks. The integration of Machine Learning (ML) into SDN holds promise for addressing these threats. While recent research demonstrates ML’s accuracy in distinguishing legitimate from malicious traffic, it faces difficulties in handling emerging, low-rate, and zero-day DDoS attacks due to limited feature scope for training. The ever-evolving DDoS landscape, driven by new protocols, necessitates continuous ML model retraining. In response to these challenges, we propose an ensemble online machine-learning model designed to enhance DDoS detection and mitigation. This approach utilizes online learning to adapt the model with expected attack patterns. The model is trained and evaluated using SDN simulation (Mininet and Ryu). Its dynamic feature selection capability overcomes conventional limitations, resulting in improved accuracy across diverse DDoS attack types. Experimental results demonstrate a remarkable 99.2% detection rate, outperforming comparable models on our custom dataset as well as various benchmark datasets, including CICDDoS2019, InSDN, and slow-read-DDoS. Moreover, the proposed model undergoes comparison with industry-standard commercial solutions. This work establishes a strong foundation for proactive DDoS threat identification and mitigation in SDN environments, reinforcing network security against evolving cyber risks.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 51630-51649
Top Cited PapersOpen AccessEnhancing DDoS Attack Detection and Mitigation in SDN Using an Ensemble Online Machine Learning Model
Software Defined Networks (SDN) offer dynamic reconfigurability and scalability, revolutionizing traditional networking. However, countering Distributed Denial of Service (DDoS) attacks remains a formidable challenge for both traditional and SDN-based networks. The integration of Machine Learning (ML) into SDN holds promise for addressing these threats. While recent research demonstrates ML’s accuracy in distinguishing legitimate from malicious traffic, it faces difficulties in handling emerging, low-rate, and zero-day DDoS attacks due to limited feature scope for training. The ever-evolving DDoS landscape, driven by new protocols, necessitates continuous ML model retraining. In response to these challenges, we propose an ensemble online machine-learning model designed to enhance DDoS detection and mitigation. This approach utilizes online learning to adapt the model with expected attack patterns. The model is trained and evaluated using SDN simulation (Mininet and Ryu). Its dynamic feature selection capability overcomes conventional limitations, resulting in improved accuracy across diverse DDoS attack types. Experimental results demonstrate a remarkable 99.2% detection rate, outperforming comparable models on our custom dataset as well as various benchmark datasets, including CICDDoS2019, InSDN, and slow-read-DDoS. Moreover, the proposed model undergoes comparison with industry-standard commercial solutions. This work establishes a strong foundation for proactive DDoS threat identification and mitigation in SDN environments, reinforcing network security against evolving cyber risks.
- Open Access
B-LIME: An Improvement of LIME for Interpretable Deep Learning Classification of Cardiac Arrhythmia from ECG Signals
Deep Learning (DL) has gained enormous popularity recently; however, it is an opaque technique that is regarded as a black box. To ensure the validity of the model’s prediction, it is necessary to explain its authenticity. A well-known locally interpretable model-agnostic explanation method (LIME) uses surrogate techniques to simulate reasonable precision and provide explanations for a given ML model. However, LIME explanations are limited to tabular, textual, and image data. They cannot be provided for signal data features that are temporally interdependent. Moreover, LIME suffers from critical problems such as instability and local fidelity that prevent its implementation in real-world environments. In this work, we propose Bootstrap-LIME (B-LIME), an improvement of LIME, to generate meaningful explanations for ECG signal data. B-LIME implies a combination of heartbeat segmentation and bootstrapping techniques to improve the model’s explainability considering the temporal dependencies between features. Furthermore, we investigate the main cause of instability and lack of local fidelity in LIME. We then propose modifications to the functionality of LIME, including the data generation technique, the explanation method, and the representation technique, to generate stable and locally faithful explanations. Finally, the performance of B-LIME in a hybrid deep-learning model for arrhythmia classification was investigated and validated in comparison with LIME. The results show that the proposed B-LIME provides more meaningful and credible explanations than LIME for cardiac arrhythmia signal data, considering the temporal dependencies between features.
Open AccessB-LIME: An Improvement of LIME for Interpretable Deep Learning Classification of Cardiac Arrhythmia from ECG Signals
Deep Learning (DL) has gained enormous popularity recently; however, it is an opaque technique that is regarded as a black box. To ensure the validity of the model’s prediction, it is necessary to explain its authenticity. A well-known locally interpretable model-agnostic explanation method (LIME) uses surrogate techniques to simulate reasonable precision and provide explanations for a given ML model. However, LIME explanations are limited to tabular, textual, and image data. They cannot be provided for signal data features that are temporally interdependent. Moreover, LIME suffers from critical problems such as instability and local fidelity that prevent its implementation in real-world environments. In this work, we propose Bootstrap-LIME (B-LIME), an improvement of LIME, to generate meaningful explanations for ECG signal data. B-LIME implies a combination of heartbeat segmentation and bootstrapping techniques to improve the model’s explainability considering the temporal dependencies between features. Furthermore, we investigate the main cause of instability and lack of local fidelity in LIME. We then propose modifications to the functionality of LIME, including the data generation technique, the explanation method, and the representation technique, to generate stable and locally faithful explanations. Finally, the performance of B-LIME in a hybrid deep-learning model for arrhythmia classification was investigated and validated in comparison with LIME. The results show that the proposed B-LIME provides more meaningful and credible explanations than LIME for cardiac arrhythmia signal data, considering the temporal dependencies between features.
- Top Cited PapersOpen Access
- 20 January 2023
- Published by MDPI AG in Mathematics
- Vol. 11 (3) , 562
Classifying Cardiac Arrhythmia from ECG Signal Using 1D CNN Deep Learning Model
Blood circulation depends critically on electrical activation, where any disturbance in the orderly pattern of the heart’s propagating wave of excitation can lead to arrhythmias. Diagnosis of arrhythmias using electrocardiograms (ECG) is widely used because they are a fast, inexpensive, and non-invasive tool. However, the randomness of arrhythmic events and the susceptibility of ECGs to noise leads to misdiagnosis of arrhythmias. In addition, manually diagnosing cardiac arrhythmias using ECG data is time-intensive and error-prone. With better training, deep learning (DL) could be a better alternative for fast and automatic classification. The present study introduces a novel deep learning architecture, specifically a one-dimensional convolutional neural network (1D-CNN), for the classification of cardiac arrhythmias. The model was trained and validated with real and noise-attenuated ECG signals from the MIT-BIH dataset. The main aim is to address the limitations of traditional electrocardiograms (ECG) in the diagnosis of arrhythmias, which can be affected by noise and randomness of events, leading to misdiagnosis and errors. To evaluate the model performance, the confusion matrix is used to calculate the model accuracy, precision, recall, f1 score, average and AUC-ROC. The experiment results demonstrate that the proposed model achieved outstanding performance, with 1.00 and 0.99 accuracies in the training and testing datasets, respectively, and can be a fast and automatic alternative for the diagnosis of arrhythmias.
- 20 January 2023
- Published by MDPI AG in Mathematics
- Vol. 11 (3) , 562
Top Cited PapersOpen AccessClassifying Cardiac Arrhythmia from ECG Signal Using 1D CNN Deep Learning Model
Blood circulation depends critically on electrical activation, where any disturbance in the orderly pattern of the heart’s propagating wave of excitation can lead to arrhythmias. Diagnosis of arrhythmias using electrocardiograms (ECG) is widely used because they are a fast, inexpensive, and non-invasive tool. However, the randomness of arrhythmic events and the susceptibility of ECGs to noise leads to misdiagnosis of arrhythmias. In addition, manually diagnosing cardiac arrhythmias using ECG data is time-intensive and error-prone. With better training, deep learning (DL) could be a better alternative for fast and automatic classification. The present study introduces a novel deep learning architecture, specifically a one-dimensional convolutional neural network (1D-CNN), for the classification of cardiac arrhythmias. The model was trained and validated with real and noise-attenuated ECG signals from the MIT-BIH dataset. The main aim is to address the limitations of traditional electrocardiograms (ECG) in the diagnosis of arrhythmias, which can be affected by noise and randomness of events, leading to misdiagnosis and errors. To evaluate the model performance, the confusion matrix is used to calculate the model accuracy, precision, recall, f1 score, average and AUC-ROC. The experiment results demonstrate that the proposed model achieved outstanding performance, with 1.00 and 0.99 accuracies in the training and testing datasets, respectively, and can be a fast and automatic alternative for the diagnosis of arrhythmias.
- Open Access
A Review of Interpretable ML in Healthcare: Taxonomy, Applications, Challenges, and Future Directions
We have witnessed the impact of ML in disease diagnosis, image recognition and classification, and many more related fields. Healthcare is a sensitive field related to people’s lives in which decisions need to be carefully taken based on solid evidence. However, most ML models are complex, i.e., black-box, meaning they do not provide insights into how the problems are solved or why such decisions are proposed. This lack of interpretability is the main reason why some ML models are not widely used yet in real environments such as healthcare. Therefore, it would be beneficial if ML models could provide explanations allowing physicians to make data-driven decisions that lead to higher quality service. Recently, several efforts have been made in proposing interpretable machine learning models to become more convenient and applicable in real environments. This paper aims to provide a comprehensive survey and symmetry phenomena of IML models and their applications in healthcare. The fundamental characteristics, theoretical underpinnings needed to develop IML, and taxonomy for IML are presented. Several examples of how they are applied in healthcare are investigated to encourage and facilitate the use of IML models in healthcare. Furthermore, current limitations, challenges, and future directions that might impact applying ML in healthcare are addressed.
Open AccessA Review of Interpretable ML in Healthcare: Taxonomy, Applications, Challenges, and Future Directions
We have witnessed the impact of ML in disease diagnosis, image recognition and classification, and many more related fields. Healthcare is a sensitive field related to people’s lives in which decisions need to be carefully taken based on solid evidence. However, most ML models are complex, i.e., black-box, meaning they do not provide insights into how the problems are solved or why such decisions are proposed. This lack of interpretability is the main reason why some ML models are not widely used yet in real environments such as healthcare. Therefore, it would be beneficial if ML models could provide explanations allowing physicians to make data-driven decisions that lead to higher quality service. Recently, several efforts have been made in proposing interpretable machine learning models to become more convenient and applicable in real environments. This paper aims to provide a comprehensive survey and symmetry phenomena of IML models and their applications in healthcare. The fundamental characteristics, theoretical underpinnings needed to develop IML, and taxonomy for IML are presented. Several examples of how they are applied in healthcare are investigated to encourage and facilitate the use of IML models in healthcare. Furthermore, current limitations, challenges, and future directions that might impact applying ML in healthcare are addressed.