Ghaid W. A. Abualzulof
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ghaid W. A. Abualzulof has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Carotti
Department of Pharmaceutical Sciences, University of Perugia, Via Fabretti 48, 06123, Perugia, Italy
1 shared publication - Carolina Barola
Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 Perugia, Italy
1 shared publication - Federica Ianni
Department of Pharmaceutical Sciences, University of Perugia, 06126 Perugia, Italy
1 shared publication - Ina Varfaj
Department of Pharmaceutical Sciences, University of Perugia
1 shared publication - Lina Cossignani
Department of Pharmaceutical Sciences, University of Perugia, 06126 Perugia, Italy
1 shared publication - Roberta Galarini
Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche "Togo Rosati", Via G. Salvemini 1, 06126 Perugia, Italy
1 shared publication
Latest Publications
- Open Access
- 11 January 2023
- Published by MDPI AG in Separations
- Vol. 10 (1) , 45
Multiple Heart-Cutting Two-Dimensional HPLC-UV Achiral–Chiral Analysis of Branched-Chain Amino Acids in Food Supplements under Environmentally Friendly Conditions
A multiple heart-cutting (mLC-LC) two-dimensional HPLC-UV achiral–chiral method for the direct analysis of branched-chain amino acids (BCAAs) in food supplements under environmentally friendly conditions was developed to cope with the very well-known limited chemoselectivity of chromatographic media for enantioselective analysis. Both achiral and chiral methods were developed in compliance with the main principles of green chromatography. The achiral analysis was performed isocratically with an optimized ion-pair reversed-phase (IP-RP) method based on a water/EtOH (95:5, v/v) mobile phase containing heptafluorobutyric acid (7 mM) as the IP agent. The achiral method was characterized by a very appreciable performance and was validated before the analysis of the real sample. High recovery values for all compounds (from 97% to 101%) were found in the interday evaluation. Additionally, low RSD% values in the long-term period were measured, in the range between 1.1% and 4.8%. Still, an LOQ value of 0.06 mg/mL was established for all compounds. The quantitative analysis of a commercial food supplement revealed that BCAAs were present in amounts very close to those declared by the producer. The enantioselective analysis was carried out through the application of the chiral ligand-exchange chromatography (CLEC) approach, using O-benzyl-(S)-serine ((S)-OBS, 0.5 mM) as the chiral selector and Cu(II) nitrate (0.25 mM) as the metal source in the eluent. Resolution and separation factor values up to 2.31 and 1.43, respectively, were obtained. The two chromatographic systems were connected through a six-port switching valve, and the developed two-dimensional mLC-LC method confirmed the absence of D-enantiomers of BCAAs in the food supplement, as reported in the manufacturer’s label.
- 11 January 2023
- Published by MDPI AG in Separations
- Vol. 10 (1) , 45
Open AccessMultiple Heart-Cutting Two-Dimensional HPLC-UV Achiral–Chiral Analysis of Branched-Chain Amino Acids in Food Supplements under Environmentally Friendly Conditions
A multiple heart-cutting (mLC-LC) two-dimensional HPLC-UV achiral–chiral method for the direct analysis of branched-chain amino acids (BCAAs) in food supplements under environmentally friendly conditions was developed to cope with the very well-known limited chemoselectivity of chromatographic media for enantioselective analysis. Both achiral and chiral methods were developed in compliance with the main principles of green chromatography. The achiral analysis was performed isocratically with an optimized ion-pair reversed-phase (IP-RP) method based on a water/EtOH (95:5, v/v) mobile phase containing heptafluorobutyric acid (7 mM) as the IP agent. The achiral method was characterized by a very appreciable performance and was validated before the analysis of the real sample. High recovery values for all compounds (from 97% to 101%) were found in the interday evaluation. Additionally, low RSD% values in the long-term period were measured, in the range between 1.1% and 4.8%. Still, an LOQ value of 0.06 mg/mL was established for all compounds. The quantitative analysis of a commercial food supplement revealed that BCAAs were present in amounts very close to those declared by the producer. The enantioselective analysis was carried out through the application of the chiral ligand-exchange chromatography (CLEC) approach, using O-benzyl-(S)-serine ((S)-OBS, 0.5 mM) as the chiral selector and Cu(II) nitrate (0.25 mM) as the metal source in the eluent. Resolution and separation factor values up to 2.31 and 1.43, respectively, were obtained. The two chromatographic systems were connected through a six-port switching valve, and the developed two-dimensional mLC-LC method confirmed the absence of D-enantiomers of BCAAs in the food supplement, as reported in the manufacturer’s label.