Restu Hikmah Ayu Murti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Restu Hikmah Ayu Murti has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Muhammad Abdus Salam Jawwad
4 shared publicationsIsna Nugraha
Department of Industrial Engineering, Faculty of Engineering, Universitas Pembangunan Nasional “Veteran” Jawa Timur, Surabaya 60294, Indonesia
3 shared publicationsRizka Novembrianto
Environmetal Engineering Department, Universitas Pembangunan Nasional “Veteran” Jawa Timur, Surabaya, Indonesia
3 shared publicationsBekti Nugrahadi
Department of Industrial Engineering, Faculty of Science, Technology, and Health, Universitas Sahid Surakarta, Indonesia
2 shared publications- Elanda Reinalda Purnama
Institut Teknologi Sepuluh November, Indonesia
2 shared publications Firra Rosariawari
Environmetal Engineering Department, Universitas Pembangunan Nasional “Veteran” Jawa Timur, Surabaya, Indonesia
2 shared publications
Latest Publications
- Open Access
- 20 August 2026
- Published by Elsevier in South African Journal of Chemical Engineering
- Vol. 58
Taguchi-optimized palmyra palm shell activated carbon for mitigating CO, HC, and NOx emissions in a fixed-bed motorcycle exhaust system
- 20 August 2026
- Published by Elsevier in South African Journal of Chemical Engineering
- Vol. 58
Open AccessTaguchi-optimized palmyra palm shell activated carbon for mitigating CO, HC, and NOx emissions in a fixed-bed motorcycle exhaust system
- Open Access
- 6 July 2026
- Published by SAFE Network in AJARCDE (Asian Journal of Applied Research for Community Development and Empowerment)
- Vol. 10 (3) , 709-714
A Study of Removal Efficiency and Kinetics of Cadmium Using Activated Carbon Derived from Sulfurized Wastewater Treatment Plant Sludge
Cadmium (Cd) pollution in water bodies requires effective treatment methods that utilize sustainable alternative materials. This study aims to analyse the efficiency of Cd removal using sulfur-modified activated carbon derived from wastewater treatment plant (WWTP) sludge at varying contact times and to analyse its adsorption kinetics. We converted wastewater treatment plant (WWTP) sludge into activated carbon via KOH activation and Na?S sulfurization. We conducted batch adsorption experiments at different contact times to evaluate Cd removal. Cd(II) removal reached 92.37% within 90 min (initial concentration: 20.32 mg/L, dosage: 2.5 g/L). The removal efficiency increased with contact time and remained relatively stable after 90 min, indicating that adsorption equilibrium had been achieved. Adsorption kinetics followed the pseudo-second-order model (R² = 0.9845), indicating chemisorption driven by sulfur surface sites. Sulfurization modified the chemical properties of the activated carbon surface and enhanced its affinity for Cd. These findings demonstrate the potential of sulfur-modified activated carbon derived from WWTP sludge as a sustainable adsorbent for Cd-contaminated water. Contribution to Sustainable Development Goals (SDGs):SDG 6: Clean Water and SanitationSDG 9: Industry, Innovation, and Infrastructure SDG 12: Responsible Consumption and Production
- 6 July 2026
- Published by SAFE Network in AJARCDE (Asian Journal of Applied Research for Community Development and Empowerment)
- Vol. 10 (3) , 709-714
Open AccessA Study of Removal Efficiency and Kinetics of Cadmium Using Activated Carbon Derived from Sulfurized Wastewater Treatment Plant Sludge
Cadmium (Cd) pollution in water bodies requires effective treatment methods that utilize sustainable alternative materials. This study aims to analyse the efficiency of Cd removal using sulfur-modified activated carbon derived from wastewater treatment plant (WWTP) sludge at varying contact times and to analyse its adsorption kinetics. We converted wastewater treatment plant (WWTP) sludge into activated carbon via KOH activation and Na?S sulfurization. We conducted batch adsorption experiments at different contact times to evaluate Cd removal. Cd(II) removal reached 92.37% within 90 min (initial concentration: 20.32 mg/L, dosage: 2.5 g/L). The removal efficiency increased with contact time and remained relatively stable after 90 min, indicating that adsorption equilibrium had been achieved. Adsorption kinetics followed the pseudo-second-order model (R² = 0.9845), indicating chemisorption driven by sulfur surface sites. Sulfurization modified the chemical properties of the activated carbon surface and enhanced its affinity for Cd. These findings demonstrate the potential of sulfur-modified activated carbon derived from WWTP sludge as a sustainable adsorbent for Cd-contaminated water. Contribution to Sustainable Development Goals (SDGs):SDG 6: Clean Water and SanitationSDG 9: Industry, Innovation, and Infrastructure SDG 12: Responsible Consumption and Production
- Open Access
- 6 July 2026
- Published by SAFE Network in AJARCDE (Asian Journal of Applied Research for Community Development and Empowerment)
- Vol. 10 (3) , 402-407
Performance of the Electro-Fenton Process in Reducing COD and TSS in Cigarette Industry Wastewater
Cigarette industry wastewater contains organic compounds and suspended solids that may adversely affect receiving water bodies when discharged without adequate treatment. This study evaluated the effects of aeration time, electric current, and contact time on dissolved oxygen (DO), chemical oxygen demand (COD), and total suspended solids (TSS) concentrations during Electro-Fenton treatment. The experiment was conducted in batch mode using a 3 L reactor, with aeration times of 0, 5, and 10 minutes, electric currents of 3, 4, and 5 A, and contact times of 10, 15, 20, 25, and 30 minutes. The initial wastewater characteristics were pH 4.8, DO 0 mg/L, COD 1,017 mg/L, and TSS 56 mg/L. Aeration increased the initial DO concentration to approximately 5.3 mg/L after 5 minutes and 6.9–7.1 mg/L after 10 minutes. The lowest final COD concentration, approximately 150 mg/L, was obtained at an electric current of 5 A, an aeration time of 10 minutes, and a contact time of 30 minutes. The lowest TSS concentration, approximately 10 mg/L, was observed at a contact time of 10 minutes under several treatment conditions. Longer contact times generally increased the TSS concentration, which was associated with the continued formation of iron-containing solids and flocs. These findings demonstrate that aeration time, electric current, and contact time influence COD and TSS concentrations during Electro-Fenton treatment of cigarette industry wastewater. Contribution to Sustainable Development Goals (SDGs):SDG 6: Clean Water and SanitationSDG 9: Industry, Innovation, and InfrastructureSDG 12: Responsible Consumption and Production
- 6 July 2026
- Published by SAFE Network in AJARCDE (Asian Journal of Applied Research for Community Development and Empowerment)
- Vol. 10 (3) , 402-407
Open AccessPerformance of the Electro-Fenton Process in Reducing COD and TSS in Cigarette Industry Wastewater
Cigarette industry wastewater contains organic compounds and suspended solids that may adversely affect receiving water bodies when discharged without adequate treatment. This study evaluated the effects of aeration time, electric current, and contact time on dissolved oxygen (DO), chemical oxygen demand (COD), and total suspended solids (TSS) concentrations during Electro-Fenton treatment. The experiment was conducted in batch mode using a 3 L reactor, with aeration times of 0, 5, and 10 minutes, electric currents of 3, 4, and 5 A, and contact times of 10, 15, 20, 25, and 30 minutes. The initial wastewater characteristics were pH 4.8, DO 0 mg/L, COD 1,017 mg/L, and TSS 56 mg/L. Aeration increased the initial DO concentration to approximately 5.3 mg/L after 5 minutes and 6.9–7.1 mg/L after 10 minutes. The lowest final COD concentration, approximately 150 mg/L, was obtained at an electric current of 5 A, an aeration time of 10 minutes, and a contact time of 30 minutes. The lowest TSS concentration, approximately 10 mg/L, was observed at a contact time of 10 minutes under several treatment conditions. Longer contact times generally increased the TSS concentration, which was associated with the continued formation of iron-containing solids and flocs. These findings demonstrate that aeration time, electric current, and contact time influence COD and TSS concentrations during Electro-Fenton treatment of cigarette industry wastewater. Contribution to Sustainable Development Goals (SDGs):SDG 6: Clean Water and SanitationSDG 9: Industry, Innovation, and InfrastructureSDG 12: Responsible Consumption and Production
- 13 January 2026
- Published by Springer Nature in Modeling Earth Systems and Environment
- Vol. 12 (1) , 73
System dynamic modelling of nanofiltration membrane in processing river water into drinking water
- 13 January 2026
- Published by Springer Nature in Modeling Earth Systems and Environment
- Vol. 12 (1) , 73
System dynamic modelling of nanofiltration membrane in processing river water into drinking water
- Open Access
- 31 December 2025
- Published by Fakultas Teknik Universitas Cendrawasih in Jurnal Wilayah, Kota dan Lingkungan Berkelanjutan
- Vol. 4 (2) , 01-08
Analisis Efektivitas Sistem Purifikasi Oli terhadap Penurunan Timbulan Limbah Oli pada Electro-Hydraulic System di PT PLN Nusantara Power UP Paiton
This research was conducted at PT PLN Nusantara Power UP Paiton, one of the largest coal-fired power plants (PLTU) in Indonesia, which focuses on reducing the generation of hazardous and toxic oil waste through the implementation of an oil purification system. The use of large amounts of lubricating oil in the Electro-Hydraulic System (EHS) has the potential to produce high amounts of used oil waste. To address this, the company implemented two main technologies, namely Water Content and Varnish Removal, which function to reduce water content and varnish layers so that the oil can be reused without reducing engine performance. This research used a quantitative descriptive method with data collection techniques through field observations, interviews, and operational documentation from 2021 to 2024. The results showed that the oil purification system was able to reduce hazardous and toxic waste generation by 11.46 tons over four years. In addition to providing environmental benefits, the implementation of this system also resulted in savings in oil waste costs of approximately Rp6,200,560,000. Technically, purification maintains engine performance by reducing water and varnish content, while from an environmental perspective, this activity supports the principle of reduce in hazardous and toxic waste management. Overall, the oil purification system has proven effective in improving operational efficiency, extending oil life, and supporting sustainable waste management for industrial operations.
- 31 December 2025
- Published by Fakultas Teknik Universitas Cendrawasih in Jurnal Wilayah, Kota dan Lingkungan Berkelanjutan
- Vol. 4 (2) , 01-08
Open AccessAnalisis Efektivitas Sistem Purifikasi Oli terhadap Penurunan Timbulan Limbah Oli pada Electro-Hydraulic System di PT PLN Nusantara Power UP Paiton
This research was conducted at PT PLN Nusantara Power UP Paiton, one of the largest coal-fired power plants (PLTU) in Indonesia, which focuses on reducing the generation of hazardous and toxic oil waste through the implementation of an oil purification system. The use of large amounts of lubricating oil in the Electro-Hydraulic System (EHS) has the potential to produce high amounts of used oil waste. To address this, the company implemented two main technologies, namely Water Content and Varnish Removal, which function to reduce water content and varnish layers so that the oil can be reused without reducing engine performance. This research used a quantitative descriptive method with data collection techniques through field observations, interviews, and operational documentation from 2021 to 2024. The results showed that the oil purification system was able to reduce hazardous and toxic waste generation by 11.46 tons over four years. In addition to providing environmental benefits, the implementation of this system also resulted in savings in oil waste costs of approximately Rp6,200,560,000. Technically, purification maintains engine performance by reducing water and varnish content, while from an environmental perspective, this activity supports the principle of reduce in hazardous and toxic waste management. Overall, the oil purification system has proven effective in improving operational efficiency, extending oil life, and supporting sustainable waste management for industrial operations.
- Open Access
- 23 December 2025
- Published by Asosiasi Riset Ilmu Manajemen dan Bisnis Indonesia in Venus: Jurnal Publikasi Rumpun Ilmu Teknik
- Vol. 3 (6) , 243-252
Evaluasi Efektifitas Pengaruh Dosis Koagulan dan Flokulan terhadap TSS dan pH Limbah Cair Stockpile Pembangkit Listrik Tenaga Uap
This study aims to evaluate the effectiveness of various doses of 6.25% Poly Aluminium Chloride (PAC) and 0.1% polymer flocculant in reducing Total Suspended Solids (TSS) and assessing pH changes in coal stockpile wastewater at PT PLN Nusantara Power UP Paiton Unit 9. Stockpile wastewater typically contains high levels of suspended solids originating from water spray activities that carry fine coal particles. The coagulation–flocculation process was performed using the jar test method with PAC dosages of 35 ppm, 50 ppm, and 65 ppm, along with flocculant dosages of 6 ppm and 7 ppm. pH and TSS were analyzed before and after treatment to assess process effectiveness. The results indicate that a PAC dosage of 35 ppm combined with a 6 ppm flocculant achieved the highest TSS removal efficiency of 98.15%. Increasing PAC dosage resulted in reduced performance due to overdosing effects, leading to charge destabilization and impaired floc formation. These findings highlight the importance of optimizing coagulant dosage to improve stockpile wastewater quality for safe reuse in operational activities.
- 23 December 2025
- Published by Asosiasi Riset Ilmu Manajemen dan Bisnis Indonesia in Venus: Jurnal Publikasi Rumpun Ilmu Teknik
- Vol. 3 (6) , 243-252
Open AccessEvaluasi Efektifitas Pengaruh Dosis Koagulan dan Flokulan terhadap TSS dan pH Limbah Cair Stockpile Pembangkit Listrik Tenaga Uap
This study aims to evaluate the effectiveness of various doses of 6.25% Poly Aluminium Chloride (PAC) and 0.1% polymer flocculant in reducing Total Suspended Solids (TSS) and assessing pH changes in coal stockpile wastewater at PT PLN Nusantara Power UP Paiton Unit 9. Stockpile wastewater typically contains high levels of suspended solids originating from water spray activities that carry fine coal particles. The coagulation–flocculation process was performed using the jar test method with PAC dosages of 35 ppm, 50 ppm, and 65 ppm, along with flocculant dosages of 6 ppm and 7 ppm. pH and TSS were analyzed before and after treatment to assess process effectiveness. The results indicate that a PAC dosage of 35 ppm combined with a 6 ppm flocculant achieved the highest TSS removal efficiency of 98.15%. Increasing PAC dosage resulted in reduced performance due to overdosing effects, leading to charge destabilization and impaired floc formation. These findings highlight the importance of optimizing coagulant dosage to improve stockpile wastewater quality for safe reuse in operational activities.
- Open Access
- 23 December 2025
- Published by Asosiasi Riset Ilmu Manajemen dan Bisnis Indonesia in Venus: Jurnal Publikasi Rumpun Ilmu Teknik
- Vol. 3 (6) , 235-242
Evaluasi Efektivitas Lapisan Area Penimbunan Faba dalam Pengendalian Kualitas Air Tanah di Sumur Pantau PT. PLN Nusantara Power UP Paiton
Fly ash and bottom ash (FABA) are combustion residues from coal-fired power plants. Following the issuance of Government Regulation No. 22 of 2021, FABA is no longer classified as hazardous and toxic waste (B3). However, FABA must still be managed properly due to its potential to cause pollution through leachate generated if leaks occur in the FABA disposal area. This study evaluates the lining and drainage systems in the FABA disposal area at PT. PLN Nusantara Power UP Paiton to ensure that leachate does not contaminate surrounding groundwater. The research employs descriptive qualitative and quantitative methods, collecting secondary data to assess the structure and pollution control systems in the FABA disposal area at PT. PLN Nusantara Power UP Paiton. The data includes the disposal area structure and water quality from monitoring wells. Analysis results indicate that the FABA disposal area lining system operates effectively and in compliance with regulations, successfully containing leachate movement and preventing seepage. This is supported by pH, Fe, Hg, and turbidity levels in groundwater from monitoring wells remaining within safe limits. Additionally, the presence of a runoff pond helps contain surface runoff during heavy rain, keeping overflow water under control. Overall, the disposal area structure and leachate management system at PT. PLN Nusantara Power UP Paiton function well, but routine monitoring must continue to ensure no seepage occurs, preventing leachate from contaminating the surrounding environment as an early preventive measure to maintain environmental quality and regulatory compliance.
- 23 December 2025
- Published by Asosiasi Riset Ilmu Manajemen dan Bisnis Indonesia in Venus: Jurnal Publikasi Rumpun Ilmu Teknik
- Vol. 3 (6) , 235-242
Open AccessEvaluasi Efektivitas Lapisan Area Penimbunan Faba dalam Pengendalian Kualitas Air Tanah di Sumur Pantau PT. PLN Nusantara Power UP Paiton
Fly ash and bottom ash (FABA) are combustion residues from coal-fired power plants. Following the issuance of Government Regulation No. 22 of 2021, FABA is no longer classified as hazardous and toxic waste (B3). However, FABA must still be managed properly due to its potential to cause pollution through leachate generated if leaks occur in the FABA disposal area. This study evaluates the lining and drainage systems in the FABA disposal area at PT. PLN Nusantara Power UP Paiton to ensure that leachate does not contaminate surrounding groundwater. The research employs descriptive qualitative and quantitative methods, collecting secondary data to assess the structure and pollution control systems in the FABA disposal area at PT. PLN Nusantara Power UP Paiton. The data includes the disposal area structure and water quality from monitoring wells. Analysis results indicate that the FABA disposal area lining system operates effectively and in compliance with regulations, successfully containing leachate movement and preventing seepage. This is supported by pH, Fe, Hg, and turbidity levels in groundwater from monitoring wells remaining within safe limits. Additionally, the presence of a runoff pond helps contain surface runoff during heavy rain, keeping overflow water under control. Overall, the disposal area structure and leachate management system at PT. PLN Nusantara Power UP Paiton function well, but routine monitoring must continue to ensure no seepage occurs, preventing leachate from contaminating the surrounding environment as an early preventive measure to maintain environmental quality and regulatory compliance.
- Open Access
- 18 June 2025
- Published by Asosiasi Riset Ilmu Manajemen dan Bisnis Indonesia in Globe: Publikasi Ilmu Teknik, Teknologi Kebumian, Ilmu Perkapalan
- Vol. 3 (3) , 01-13
Analisis Potensi Penurunan Muka Air Tanah di Salah Satu Bandar Udara Jawa Timur
Nowadays, groundwater in the world has been widely exploited along with the increasing population. One of the impacts of massive groundwater extraction is the decline in groundwater levels. This potential could occur at one of the airports in East Java which is one of the most crowded airports in Indonesia. The large number of passengers at the airport has increased groundwater extraction due to the increasing need for sanitation, airport facilities, and other operational needs. This study aims to determine the potential for groundwater level decline at one of the airports in East Java. The research method used is a quantitative method by projecting secondary data from the results of groundwater level sampling carried out every 6 months. The results of the study showed a decline in groundwater levels at one of the airports in East Java in the next 20 years due to the increase in passengers each year. The results of this study are expected to be one of the preventive steps for all of us to maintain the sustainability of groundwater resources.
- 18 June 2025
- Published by Asosiasi Riset Ilmu Manajemen dan Bisnis Indonesia in Globe: Publikasi Ilmu Teknik, Teknologi Kebumian, Ilmu Perkapalan
- Vol. 3 (3) , 01-13
Open AccessAnalisis Potensi Penurunan Muka Air Tanah di Salah Satu Bandar Udara Jawa Timur
Nowadays, groundwater in the world has been widely exploited along with the increasing population. One of the impacts of massive groundwater extraction is the decline in groundwater levels. This potential could occur at one of the airports in East Java which is one of the most crowded airports in Indonesia. The large number of passengers at the airport has increased groundwater extraction due to the increasing need for sanitation, airport facilities, and other operational needs. This study aims to determine the potential for groundwater level decline at one of the airports in East Java. The research method used is a quantitative method by projecting secondary data from the results of groundwater level sampling carried out every 6 months. The results of the study showed a decline in groundwater levels at one of the airports in East Java in the next 20 years due to the increase in passengers each year. The results of this study are expected to be one of the preventive steps for all of us to maintain the sustainability of groundwater resources.
- Open Access
- 21 January 2025
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in Jurnal Presipitasi : Media Komunikasi dan Pengembangan Teknik Lingkungan
- Vol. 22 (1) , 81-94
Enhancing Ibuprofen Degradation through Optimization of ZrCo Synthesis Catalyst in Membrane Distillation
This study will optimize ZrCo as a catalyst applied to the surface of porous membranes to remove micropollutants, specifically ibuprofen. This method improves the reaction rate and accelerates the chain degradation of Ibuprofen, thereby preventing blockage caused by impurities in the membrane pores. The catalyst synthesis was performed using a hydrothermal method with ZrCl4 and CoCl2·6H2O as the primary materials. This method is employed to produce a high purity catalyst and yield a more stable catalyst. This research will measure the optimal catalyst through flux and removal efficiency during the membrane distillation process for 1 hour. Reaction conditions were adjusted using Air Gap Membrane Distillation at 80°C heating temperature, 4 L/min flow rate, and 1.5 mmol/L peroxymonosulfate as pre-oxidation. Experiments were conducted by comparing 9 types of catalysts, from which the best calcination temperature was selected for catalyst concentration optimization. Based on the flux and removal data tested statistically, the optimum catalyst type and calcination temperature were achieved at a 2:1 composition with a calcination temperature of 600°C, yielding flux and removal efficiency values of 7.0238 LMH and 98.53%. Meanwhile, the optimum catalyst concentration was obtained at 0.5 wt%, with flux and removal efficiency values of 8.05 LMH and 99.83%.
- 21 January 2025
- Published by Institute of Research and Community Services Diponegoro University (LPPM UNDIP) in Jurnal Presipitasi : Media Komunikasi dan Pengembangan Teknik Lingkungan
- Vol. 22 (1) , 81-94
Open AccessEnhancing Ibuprofen Degradation through Optimization of ZrCo Synthesis Catalyst in Membrane Distillation
This study will optimize ZrCo as a catalyst applied to the surface of porous membranes to remove micropollutants, specifically ibuprofen. This method improves the reaction rate and accelerates the chain degradation of Ibuprofen, thereby preventing blockage caused by impurities in the membrane pores. The catalyst synthesis was performed using a hydrothermal method with ZrCl4 and CoCl2·6H2O as the primary materials. This method is employed to produce a high purity catalyst and yield a more stable catalyst. This research will measure the optimal catalyst through flux and removal efficiency during the membrane distillation process for 1 hour. Reaction conditions were adjusted using Air Gap Membrane Distillation at 80°C heating temperature, 4 L/min flow rate, and 1.5 mmol/L peroxymonosulfate as pre-oxidation. Experiments were conducted by comparing 9 types of catalysts, from which the best calcination temperature was selected for catalyst concentration optimization. Based on the flux and removal data tested statistically, the optimum catalyst type and calcination temperature were achieved at a 2:1 composition with a calcination temperature of 600°C, yielding flux and removal efficiency values of 7.0238 LMH and 98.53%. Meanwhile, the optimum catalyst concentration was obtained at 0.5 wt%, with flux and removal efficiency values of 8.05 LMH and 99.83%.
- Open Access
- 31 March 2024
- Published by Universitas Islam Lamongan in Jurnal Enviscience
- Vol. 8 (1) , 86-95
Dispersi Pencemaran Udara Dengan Parameter Sulfur Dioksida (SO2 ) Pada PLTGU Di PT PLN Nusantara Power UP GRESIK
Kabupaten Gresik merupakan salah satu kabupaten yang dikenal sebagai kota industri. Alasan mengapa Kabupaten Gresik disebut sebagai Kota Industri adalah karena banyaknya industri yang ada di Kabupaten Gresik. Jumlah industri terbesar sebanyak industri terdapat di Kabupaten Gresik sebanyak 304 industri dan di Kabupaten Kebomas sebanyak 2.034 industri. Banyaknya jumlah industri di Kabupaten Gresik. PT PLN Nusantara Power UP Gresik. PT PLN Nusantara Power UP Gresik merupakan salah satu Unit Pembangkit yang mempunyai impact dalam penyumbang emisi di wilayah Gresik. Penelitian ini bertujuan untuk untuk mengetahui persebaran udara yang dihasilkan oleh proses produksi pada PLTGU di PT PLN Nusantara Power UP di Gresik dalam memproduksi listrik dengan sistem combine cycle. Model simulasi menggunkan software AERMOD View dengan data meteorologi stasiun Sangkapura. Hasil menunjukkan bahwa industri PLTGU memberikan dampak emisi di area pemukiman yang berada di sisi barat, utara dan Selatan lokasi kegiatan, sebagaimana persebaran arah angin non dominan bergerak ke arah tersebut, Secara dominan persebaran konsentrasi terbesar ke arah timur sumber emisi sesuai dengan arah angin dominan. namun konsentrasi yang dihasilkan masih dibawah batas yang diijinkan pada baku mutu, yang tertera pada Lampiran VII PP No 22 Tahun 2021. Faktor yang mempengaruhi sebaran konsentrasi ini antara lain dari tinggi dan ukuran cerobong yang terpasang di PT PLN Nusantara Power UP Gresik.
- 31 March 2024
- Published by Universitas Islam Lamongan in Jurnal Enviscience
- Vol. 8 (1) , 86-95
Open AccessDispersi Pencemaran Udara Dengan Parameter Sulfur Dioksida (SO2 ) Pada PLTGU Di PT PLN Nusantara Power UP GRESIK
Kabupaten Gresik merupakan salah satu kabupaten yang dikenal sebagai kota industri. Alasan mengapa Kabupaten Gresik disebut sebagai Kota Industri adalah karena banyaknya industri yang ada di Kabupaten Gresik. Jumlah industri terbesar sebanyak industri terdapat di Kabupaten Gresik sebanyak 304 industri dan di Kabupaten Kebomas sebanyak 2.034 industri. Banyaknya jumlah industri di Kabupaten Gresik. PT PLN Nusantara Power UP Gresik. PT PLN Nusantara Power UP Gresik merupakan salah satu Unit Pembangkit yang mempunyai impact dalam penyumbang emisi di wilayah Gresik. Penelitian ini bertujuan untuk untuk mengetahui persebaran udara yang dihasilkan oleh proses produksi pada PLTGU di PT PLN Nusantara Power UP di Gresik dalam memproduksi listrik dengan sistem combine cycle. Model simulasi menggunkan software AERMOD View dengan data meteorologi stasiun Sangkapura. Hasil menunjukkan bahwa industri PLTGU memberikan dampak emisi di area pemukiman yang berada di sisi barat, utara dan Selatan lokasi kegiatan, sebagaimana persebaran arah angin non dominan bergerak ke arah tersebut, Secara dominan persebaran konsentrasi terbesar ke arah timur sumber emisi sesuai dengan arah angin dominan. namun konsentrasi yang dihasilkan masih dibawah batas yang diijinkan pada baku mutu, yang tertera pada Lampiran VII PP No 22 Tahun 2021. Faktor yang mempengaruhi sebaran konsentrasi ini antara lain dari tinggi dan ukuran cerobong yang terpasang di PT PLN Nusantara Power UP Gresik.