SAS. M. Aston

S. M. Aston

*This is an algorithmically generated author record based on publicly available information.

S. M. Aston has a total of 178 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit

    by Wenxuan Jia, Victoria Xu, Kevin Kuns, Masayuki Nakano, Lisa Barsotti, Matthew Evans, Nergis Mavalvala, members of the LIGO Scientific Collaboration†, R. Abbott, I. Abouelfettouh, et al.

    The Heisenberg uncertainty principle dictates that the position and momentum of an object cannot be simultaneously measured with arbitrary precision, giving rise to an apparent limitation known as the standard quantum limit (SQL). Gravitational-wave detectors use photons to continuously measure the positions of freely falling mirrors and so are affected by the SQL. We investigated the performance of the Laser Interferometer Gravitational-Wave Observatory (LIGO) after the experimental realization of frequency-dependent squeezing designed to surpass the SQL. For the LIGO Livingston detector, we found that the upgrade reduces quantum noise below the SQL by a maximum of three decibels between 35 and 75 hertz while achieving a broadband sensitivity improvement, increasing the overall detector sensitivity during astrophysical observations.


  • Open Access

    Sensors and actuators for the advanced LIGO A+ upgrade

    by S. J. Cooper, C. M. Mow-Lowry, D. Hoyland, J. Bryant, A. Ubhi, J. O’dEll, A. Huddart, S. Aston, A. Vecchio

    Advanced Laser Interferometer Gravitational-wave Observatory (LIGO A+) is a major upgrade to LIGO—the Laser Interferometer Gravitational-wave Observatory. For the A+ project, we have developed, produced, and characterized sensors and electronics to interrogate new optical suspensions designed to isolate optics from vibrations. The central element is a displacement sensor with an integrated electromagnetic actuator known as a BOSEM (Birmingham Optical Sensor and ElectroMagnetic actuator) and its readout and drive electronics required to integrate them into LIGO’s control and data system. In this paper, we report on the improvements to the sensors and the testing procedures undertaken to meet the enhanced performance requirements set out by the A+ upgrade to the detectors. The best devices reach a noise level of 4.5 ×10−11m/Hz at a measurement frequency of 1 Hz, an improvement of 6.7 times over standard devices.