Thomas Niederhoffer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas Niederhoffer has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Anne Vanhoestenberghe
School of Biomedical Engineering and Imaging Sciences King's College London London UK
2 shared publications - Henry Thomas Lancashire
University College London
2 shared publications
Latest Publications
- Open Access
- 9 September 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (5) , 056007
Extending the understanding of Shannon’s safe stimulation limit for platinum electrodes: biphasic charge-balanced pulse trains in unbuffered saline at pH = 1 to pH = 12
Objective. In neural electrical stimulation, safe stimulation guidelines are essential to deliver efficient treatment while avoiding neural damage and electrode degradation. The widely used Shannon’s limit, k, gives conditions on the stimulation parameters to avoid neural damage, however, underlying damage mechanisms are not fully understood. Moreover, the translation from bench testing to in vivo experiments still presents some challenges, including the increased polarisation observed, which may influence charge-injection mechanisms. In this work, we studied the influence on damage mechanisms of two electrolyte parameters that are different in vivo compared to usual bench tests: solution pH and electrolyte gelation. Approach. The potential of a platinum macroelectrode was monitored in a three-electrode setup during current-controlled biphasic charge-balanced cathodic-first pulse trains. Maximum anodic and cathodic potential excursions during pulse trains were projected on cyclic voltammograms to infer possible electrochemical reactions. Main results. In unbuffered saline of pH ranging from 1 to 12, the maximum anodic potential was systematically located in the oxide formation region, while the cathodic potential was located the molecular oxygen and oxide reduction region when k approached Shannon’s damage limit, independent of solution pH. The results support the hypothesis that Shannon’s limit corresponds to the beginning of platinum dissolution following repeated cycles of platinum oxidation and reduction, for which the cathodic excursion is a key tipping point. Despite similar potential excursions between solution and gel electrolytes, we found a joint influence of pH and gelation on the cathodic potential alone, while we observed no effect on the anodic potential. We hypothesise that gelation creates a positive feedback loop exacerbating the effects of pH ; however, the extent of that influence needs to be examined further. Significance. This work supports the hypothesis of charge injection mechanisms associated with stimulation-induced damage at platinum electrodes. The validity of a major hypothesis explaining stimulation-induced damage was tested and supported on a range of electrolytes representing potential electrode environments, calling for further characterisation of platinum dissolution during electrical stimulation in various testing conditions.
- 9 September 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (5) , 056007
Open AccessExtending the understanding of Shannon’s safe stimulation limit for platinum electrodes: biphasic charge-balanced pulse trains in unbuffered saline at pH = 1 to pH = 12
Objective. In neural electrical stimulation, safe stimulation guidelines are essential to deliver efficient treatment while avoiding neural damage and electrode degradation. The widely used Shannon’s limit, k, gives conditions on the stimulation parameters to avoid neural damage, however, underlying damage mechanisms are not fully understood. Moreover, the translation from bench testing to in vivo experiments still presents some challenges, including the increased polarisation observed, which may influence charge-injection mechanisms. In this work, we studied the influence on damage mechanisms of two electrolyte parameters that are different in vivo compared to usual bench tests: solution pH and electrolyte gelation. Approach. The potential of a platinum macroelectrode was monitored in a three-electrode setup during current-controlled biphasic charge-balanced cathodic-first pulse trains. Maximum anodic and cathodic potential excursions during pulse trains were projected on cyclic voltammograms to infer possible electrochemical reactions. Main results. In unbuffered saline of pH ranging from 1 to 12, the maximum anodic potential was systematically located in the oxide formation region, while the cathodic potential was located the molecular oxygen and oxide reduction region when k approached Shannon’s damage limit, independent of solution pH. The results support the hypothesis that Shannon’s limit corresponds to the beginning of platinum dissolution following repeated cycles of platinum oxidation and reduction, for which the cathodic excursion is a key tipping point. Despite similar potential excursions between solution and gel electrolytes, we found a joint influence of pH and gelation on the cathodic potential alone, while we observed no effect on the anodic potential. We hypothesise that gelation creates a positive feedback loop exacerbating the effects of pH ; however, the extent of that influence needs to be examined further. Significance. This work supports the hypothesis of charge injection mechanisms associated with stimulation-induced damage at platinum electrodes. The validity of a major hypothesis explaining stimulation-induced damage was tested and supported on a range of electrolytes representing potential electrode environments, calling for further characterisation of platinum dissolution during electrical stimulation in various testing conditions.
- Open Access
- 31 January 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (1) , 011002
Methods of poly(3,4)-ethylenedioxithiophene (PEDOT) electrodeposition on metal electrodes for neural stimulation and recording
Conductive polymers are of great interest in the field of neural electrodes because of their potential to improve the interfacial properties of electrodes. In particular, the conductive polymer poly (3,4)-ethylenedioxithiophene (PEDOT) has been widely studied for neural applications. Objective: This review compares methods for electrodeposition of PEDOT on metal neural electrodes, and analyses the effects of deposition methods on morphology and electrochemical performance. Approach: Electrochemical performances were analysed against several deposition method choices, including deposition charge density and co-ion, and correlations were explained to morphological and structural arguments as well as characterisation methods choices. Main results: Coating thickness and charge storage capacity are positively correlated with PEDOT electrodeposition charge density. We also show that PEDOT coated electrode impedance at 1 kHz, the only consistently reported impedance quantity, is strongly dependent upon electrode radius across a wide range of studies, because PEDOT coatings reduces the reactance of the complex impedance, conferring a more resistive behaviour to electrodes (at 1 kHz) dominated by the solution resistance and electrode geometry. This review also summarises how PEDOT co-ion choice affects coating structure and morphology and shows that co-ions notably influence the charge injection limit but have a limited influence on charge storage capacity and impedance. Finally we discuss the possible influence of characterisation methods to assess the robustness of comparisons between published results using different methods of characterisation. Significance: This review aims to serve as a common basis for researchers working with PEDOT by showing the effects of deposition methods on electrochemical performance, and aims to set a standard for accurate and uniform reporting of methods.
- 31 January 2023
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 20 (1) , 011002
Open AccessMethods of poly(3,4)-ethylenedioxithiophene (PEDOT) electrodeposition on metal electrodes for neural stimulation and recording
Conductive polymers are of great interest in the field of neural electrodes because of their potential to improve the interfacial properties of electrodes. In particular, the conductive polymer poly (3,4)-ethylenedioxithiophene (PEDOT) has been widely studied for neural applications. Objective: This review compares methods for electrodeposition of PEDOT on metal neural electrodes, and analyses the effects of deposition methods on morphology and electrochemical performance. Approach: Electrochemical performances were analysed against several deposition method choices, including deposition charge density and co-ion, and correlations were explained to morphological and structural arguments as well as characterisation methods choices. Main results: Coating thickness and charge storage capacity are positively correlated with PEDOT electrodeposition charge density. We also show that PEDOT coated electrode impedance at 1 kHz, the only consistently reported impedance quantity, is strongly dependent upon electrode radius across a wide range of studies, because PEDOT coatings reduces the reactance of the complex impedance, conferring a more resistive behaviour to electrodes (at 1 kHz) dominated by the solution resistance and electrode geometry. This review also summarises how PEDOT co-ion choice affects coating structure and morphology and shows that co-ions notably influence the charge injection limit but have a limited influence on charge storage capacity and impedance. Finally we discuss the possible influence of characterisation methods to assess the robustness of comparisons between published results using different methods of characterisation. Significance: This review aims to serve as a common basis for researchers working with PEDOT by showing the effects of deposition methods on electrochemical performance, and aims to set a standard for accurate and uniform reporting of methods.