Shauna L. Heinrich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shauna L. Heinrich has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- David K. Gardner
School of Biosciences, Faculty of Science, Bio21 Institute, The University of Melbourne , Parkville, Victoria
3 shared publications - Hanna Julie McLennan
Fertilis Pty Ltd, Frome Road, Helen Mayo South, The University of Adelaide, Adelaide, SA 5005, Australia
3 shared publications - Jeremy G. Thompson
Australian Research Council (ARC) Centre of Excellence for Nanoscale BioPhotonics (CNBP), Adelaide, Australia
3 shared publications - Adam J. Blanch
University of Melbourne
2 shared publications - Allison K. Love
Fertilis Pty Ltd, Frome Road, Helen Mayo South, The University of Adelaide, Adelaide, Australia
2 shared publications - Kylie R. Dunning
Adelaide University
2 shared publications
Latest Publications
- Open Access
- 20 June 2024
- Published by CSIRO Publishing in Reproduction, Fertility and Development
- Vol. 36 (10)
A brief history of technical developments in intracytoplasmic sperm injection (ICSI). Dedicated to the memory of J.M. Cummins
Intracytoplasmic sperm injection (ICSI) is an assisted reproductive technology for treatment of severe male infertility introduced into clinical practice in 1992. This review provides a brief history of the development of ICSI by acknowledging major developments in the field. The review addresses key developments in pre-clinical and early studies, how ICSI compares with in vitro fertilisation, long-term consequences, how the mechanistic approach to ICSI has changed in both manual and semi-automated approaches, and how sperm selection procedures are integrated into ICSI. From the beginnings using animal models in the 1960–1970s, the development of ICSI is a remarkable and transformative success story. Indeed, its broad use (70% of cycles globally) exceeds the need required for treating infertile males, and this remains a controversial issue. There remain questions around the long-term health impacts of ICSI. Furthermore, advances in automation of the ICSI procedure are occurring. An estimated 6 million children have been born from the ICSI procedure. With further automation of sperm selection technologies, coupled with automation of the injection procedure, it is likely that the proportion of children born from ICSI will further increase.
- 20 June 2024
- Published by CSIRO Publishing in Reproduction, Fertility and Development
- Vol. 36 (10)
Open AccessA brief history of technical developments in intracytoplasmic sperm injection (ICSI). Dedicated to the memory of J.M. Cummins
Intracytoplasmic sperm injection (ICSI) is an assisted reproductive technology for treatment of severe male infertility introduced into clinical practice in 1992. This review provides a brief history of the development of ICSI by acknowledging major developments in the field. The review addresses key developments in pre-clinical and early studies, how ICSI compares with in vitro fertilisation, long-term consequences, how the mechanistic approach to ICSI has changed in both manual and semi-automated approaches, and how sperm selection procedures are integrated into ICSI. From the beginnings using animal models in the 1960–1970s, the development of ICSI is a remarkable and transformative success story. Indeed, its broad use (70% of cycles globally) exceeds the need required for treating infertile males, and this remains a controversial issue. There remain questions around the long-term health impacts of ICSI. Furthermore, advances in automation of the ICSI procedure are occurring. An estimated 6 million children have been born from the ICSI procedure. With further automation of sperm selection technologies, coupled with automation of the injection procedure, it is likely that the proportion of children born from ICSI will further increase.
- Open Access
- 18 January 2024
- Published by Springer Nature in Journal of Assisted Reproduction and Genetics
- Vol. 41 (2) , 297-309
A micro-fabricated device (microICSI) improves porcine blastocyst development and procedural efficiency for both porcine intracytoplasmic sperm injection and human microinjection
Purpose: Intracytoplasmic sperm injection (ICSI) imparts physical stress on the oolemma of the oocyte and remains among the most technically demanding skills to master, with success rates related to experience and expertise. ICSI is also time-consuming and requires workflow management in the laboratory. This study presents a device designed to reduce the pressure on the oocyte during injection and investigates if this improves embryo development in a porcine model. The impact of this device on laboratory workflow was also assessed. Methods: Porcine oocytes were matured in vitro and injected with porcine sperm by conventional ICSI (C-ICSI) or with microICSI, an ICSI dish that supports up to 20 oocytes housed individually in microwells created through microfabrication. Data collected included set-up time, time to align the polar body, time to perform the injection, the number of hand adjustments between controllers, and degree of invagination at injection. Developmental parameters measured included cleavage and day 6 blastocyst rates. Blastocysts were differentially stained to assess cell numbers of the inner cell mass and trophectoderm. A pilot study with human donated MII oocytes injected with beads was also performed. Results: A significant increase in porcine blastocyst rate for microICSI compared to C-ICSI was observed, while cleavage rates and blastocyst cell numbers were comparable between treatments. Procedural efficiency of microinjection was significantly improved with microICSI compared to C-ICSI in both species. Conclusion: The microICSI device demonstrated significant developmental and procedural benefits for porcine ICSI. A pilot study suggests human ICSI should benefit equally.
- 18 January 2024
- Published by Springer Nature in Journal of Assisted Reproduction and Genetics
- Vol. 41 (2) , 297-309
Open AccessA micro-fabricated device (microICSI) improves porcine blastocyst development and procedural efficiency for both porcine intracytoplasmic sperm injection and human microinjection
Purpose: Intracytoplasmic sperm injection (ICSI) imparts physical stress on the oolemma of the oocyte and remains among the most technically demanding skills to master, with success rates related to experience and expertise. ICSI is also time-consuming and requires workflow management in the laboratory. This study presents a device designed to reduce the pressure on the oocyte during injection and investigates if this improves embryo development in a porcine model. The impact of this device on laboratory workflow was also assessed. Methods: Porcine oocytes were matured in vitro and injected with porcine sperm by conventional ICSI (C-ICSI) or with microICSI, an ICSI dish that supports up to 20 oocytes housed individually in microwells created through microfabrication. Data collected included set-up time, time to align the polar body, time to perform the injection, the number of hand adjustments between controllers, and degree of invagination at injection. Developmental parameters measured included cleavage and day 6 blastocyst rates. Blastocysts were differentially stained to assess cell numbers of the inner cell mass and trophectoderm. A pilot study with human donated MII oocytes injected with beads was also performed. Results: A significant increase in porcine blastocyst rate for microICSI compared to C-ICSI was observed, while cleavage rates and blastocyst cell numbers were comparable between treatments. Procedural efficiency of microinjection was significantly improved with microICSI compared to C-ICSI in both species. Conclusion: The microICSI device demonstrated significant developmental and procedural benefits for porcine ICSI. A pilot study suggests human ICSI should benefit equally.
- Open Access
- 11 January 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-16
Nano-liter perfusion microfluidic device made entirely by two-photon polymerization for dynamic cell culture with easy cell recovery
Polydimethylsiloxane (PDMS) has been the material of choice for microfluidic applications in cell biology for many years, with recent advances encompassing nano-scaffolds and surface modifications to enhance cell-surface interactions at nano-scale. However, PDMS has not previously been amenable to applications which require complex geometries in three dimensions for cell culture device fabrication in the absence of additional components. Further, PDMS microfluidic devices have limited capacity for cell retrieval following culture without severely compromising cell health. This study presents a designed and entirely 3D-printed microfluidic chip (8.8 mm × 8.2 mm × 3.6 mm) using two-photon polymerization (2PP). The ‘nest’ chip is composed of ten channels that deliver sub-microliter volume flowrates (to ~ 600 nL/min per channel) to 10 individual retrievable cell sample ‘cradles’ that interlock with the nest to create the microfluidic device. Computational fluid dynamics modelling predicted medium flow in the device, which was accurately validated by real-time microbead tracking. Functional capability of the device was assessed, and demonstrated the capability to deliver culture medium, dyes, and biological molecules to support cell growth, staining and cell phenotype changes, respectively. Therefore, 2PP 3D-printing provides the precision needed for nanoliter fluidic devices constructed from multiple interlocking parts for cell culture application.
- 11 January 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-16
Open AccessNano-liter perfusion microfluidic device made entirely by two-photon polymerization for dynamic cell culture with easy cell recovery
Polydimethylsiloxane (PDMS) has been the material of choice for microfluidic applications in cell biology for many years, with recent advances encompassing nano-scaffolds and surface modifications to enhance cell-surface interactions at nano-scale. However, PDMS has not previously been amenable to applications which require complex geometries in three dimensions for cell culture device fabrication in the absence of additional components. Further, PDMS microfluidic devices have limited capacity for cell retrieval following culture without severely compromising cell health. This study presents a designed and entirely 3D-printed microfluidic chip (8.8 mm × 8.2 mm × 3.6 mm) using two-photon polymerization (2PP). The ‘nest’ chip is composed of ten channels that deliver sub-microliter volume flowrates (to ~ 600 nL/min per channel) to 10 individual retrievable cell sample ‘cradles’ that interlock with the nest to create the microfluidic device. Computational fluid dynamics modelling predicted medium flow in the device, which was accurately validated by real-time microbead tracking. Functional capability of the device was assessed, and demonstrated the capability to deliver culture medium, dyes, and biological molecules to support cell growth, staining and cell phenotype changes, respectively. Therefore, 2PP 3D-printing provides the precision needed for nanoliter fluidic devices constructed from multiple interlocking parts for cell culture application.