Gizem Yilmaz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gizem Yilmaz has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Michael Wei Liang Chee
National University of Singapore
5 shared publications - Ju Lynn Ong
National University of Singapore
3 shared publications - Lieng Hsi Ling
Yong Loo Lin School of Medicine, National University of Singapore
2 shared publications - Andrew Roshan Dicom
Sleep and Cognition Laboratory, Centre for Sleep and Cognition, Yong Loo Lin School of Medicine, National University of Singapore
1 shared publication B. T. Thomas Yeo
1 shared publication- Boon Thye Thomas Yeo
National University of Singapore, Singapore
1 shared publication
Latest Publications
- Open Access
- 30 March 2026
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 5 (3) , e0001329
Vascular age estimation using a consumer wearable sleep tracker
Vascular aging is traditionally assessed using a combination of clinical markers, blood pressure and arterial stiffness measurement. However, measuring vascular aging with reference equipment is costly and not scalable. Nocturnal photoplethysmography (PPG) from wearable health trackers offer a scalable solution for longitudinal assessment. In this study, we evaluated the ability of a consumer wearable (Oura Ring) to detect age-related differences in PPG waveform, in comparison to a clinical-grade fingertip pulse oximeter. Healthy adults (N = 160; 78 males (49%), median age 31 years (IQR: 23)) underwent overnight polysomnography (PSG) in a sleep laboratory, during which fingertip and wearable ring PPG data were collected simultaneously. Pulse waveforms were extracted from both devices using a custom algorithm and key waveform features were compared across devices. Vascular age was estimated from pulse waveforms using a featureless deep learning model. Prediction performance was compared between the two devices. Age-related waveform changes were most prominent in PPG crest time (CT (samples)) (r = 0.64 and 0.62 for fingertip and wearable devices), while the reflection index (RI) had a weaker correlation with age for the ring sensor (r = 0.22) compared to fingertip (r = 0.58). Despite differences in waveforms between devices, the deep learning model showed comparable prediction performance with mean absolute errors (MAE (SD)) of 6.28 (1.48) and 7.25 (1.29) years, and r (SD) of 0.84 (0.07) and 0.80 (0.10) for clinical-grade and consumer-grade devices, respectively. These findings support the feasibility of using PPG waveforms from wearable devices to assess vascular age.
- 30 March 2026
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 5 (3) , e0001329
Open AccessVascular age estimation using a consumer wearable sleep tracker
Vascular aging is traditionally assessed using a combination of clinical markers, blood pressure and arterial stiffness measurement. However, measuring vascular aging with reference equipment is costly and not scalable. Nocturnal photoplethysmography (PPG) from wearable health trackers offer a scalable solution for longitudinal assessment. In this study, we evaluated the ability of a consumer wearable (Oura Ring) to detect age-related differences in PPG waveform, in comparison to a clinical-grade fingertip pulse oximeter. Healthy adults (N = 160; 78 males (49%), median age 31 years (IQR: 23)) underwent overnight polysomnography (PSG) in a sleep laboratory, during which fingertip and wearable ring PPG data were collected simultaneously. Pulse waveforms were extracted from both devices using a custom algorithm and key waveform features were compared across devices. Vascular age was estimated from pulse waveforms using a featureless deep learning model. Prediction performance was compared between the two devices. Age-related waveform changes were most prominent in PPG crest time (CT (samples)) (r = 0.64 and 0.62 for fingertip and wearable devices), while the reflection index (RI) had a weaker correlation with age for the ring sensor (r = 0.22) compared to fingertip (r = 0.58). Despite differences in waveforms between devices, the deep learning model showed comparable prediction performance with mean absolute errors (MAE (SD)) of 6.28 (1.48) and 7.25 (1.29) years, and r (SD) of 0.84 (0.07) and 0.80 (0.10) for clinical-grade and consumer-grade devices, respectively. These findings support the feasibility of using PPG waveforms from wearable devices to assess vascular age.
- Open Access
Deriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring
Cardiovascular diseases are a major cause of mortality worldwide. Long-term monitoring of nighttime heart rate (HR) and heart rate variability (HRV) may be useful in identifying latent cardiovascular risk. The Oura Ring has shown excellent correlation only with ECG-derived HR, but not HRV. We thus assessed if stringent data quality filters can improve the accuracy of time-domain and frequency-domain HRV measures. 92 younger (<45 years) and 22 older (≥45 years) participants from two in-lab sleep studies with concurrent overnight Oura and ECG data acquisition were analyzed. For each 5 min segment during time-in-bed, the validity proportion (percentage of interbeat intervals rated as valid) was calculated. We evaluated the accuracy of Oura-derived HR and HRV measures against ECG at different validity proportion thresholds: 80%, 50%, and 30%; and aggregated over different durations: 5 min, 30 min, and Night-level. Strong correlation and agreements were obtained for both age groups across all HR and HRV metrics and window sizes. More stringent validity proportion thresholds and averaging over longer time windows (i.e., 30 min and night) improved accuracy. Higher discrepancies were found for HRV measures, with more than half of older participants exceeding 10% Median Absolute Percentage Error. Accurate HRV measures can be obtained from Oura’s PPG-derived signals with a stringent validity proportion threshold of around 80% for each 5 min segment and aggregating over time windows of at least 30 min.
Open AccessDeriving Accurate Nocturnal Heart Rate, rMSSD and Frequency HRV from the Oura Ring
Cardiovascular diseases are a major cause of mortality worldwide. Long-term monitoring of nighttime heart rate (HR) and heart rate variability (HRV) may be useful in identifying latent cardiovascular risk. The Oura Ring has shown excellent correlation only with ECG-derived HR, but not HRV. We thus assessed if stringent data quality filters can improve the accuracy of time-domain and frequency-domain HRV measures. 92 younger (<45 years) and 22 older (≥45 years) participants from two in-lab sleep studies with concurrent overnight Oura and ECG data acquisition were analyzed. For each 5 min segment during time-in-bed, the validity proportion (percentage of interbeat intervals rated as valid) was calculated. We evaluated the accuracy of Oura-derived HR and HRV measures against ECG at different validity proportion thresholds: 80%, 50%, and 30%; and aggregated over different durations: 5 min, 30 min, and Night-level. Strong correlation and agreements were obtained for both age groups across all HR and HRV metrics and window sizes. More stringent validity proportion thresholds and averaging over longer time windows (i.e., 30 min and night) improved accuracy. Higher discrepancies were found for HRV measures, with more than half of older participants exceeding 10% Median Absolute Percentage Error. Accurate HRV measures can be obtained from Oura’s PPG-derived signals with a stringent validity proportion threshold of around 80% for each 5 min segment and aggregating over time windows of at least 30 min.
- Open Access
Nocturnal Blood Pressure Estimation from Sleep Plethysmography Using Machine Learning
Background: Elevated nocturnal blood pressure (BP) is a risk factor for cardiovascular disease (CVD) and mortality. Cuffless BP assessment aided by machine learning could be a desirable alternative to traditional cuff-based methods for monitoring BP during sleep. We describe a machine-learning-based algorithm for predicting nocturnal BP using single-channel fingertip plethysmography (PPG) in healthy adults. Methods: Sixty-eight healthy adults with no apparent sleep or CVD (53% male), with a median (IQR) age of 29 (23–46 years), underwent overnight polysomnography (PSG) with fingertip PPG and ambulatory blood pressure monitoring (ABPM). Features based on pulse morphology were extracted from the PPG waveforms. Random forest models were used to predict night-time systolic blood pressure (SBP) and diastolic blood pressure (DBP). Results: Our model achieved the highest out-of-sample performance with a window length of 7 s across window lengths explored (60 s, 30 s, 15 s, 7 s, and 3 s). The mean absolute error (MAE ± STD) was 5.72 ± 4.51 mmHg for SBP and 4.52 ± 3.60 mmHg for DBP. Similarly, the root mean square error (RMSE ± STD) was 6.47 ± 1.88 mmHg for SBP and 4.62 ± 1.17 mmHg for DBP. The mean correlation coefficient between measured and predicted values was 0.87 for SBP and 0.86 for DBP. Based on Shapley additive explanation (SHAP) values, the most important PPG waveform feature was the stiffness index, a marker that reflects the change in arterial stiffness. Conclusion: Our results highlight the potential of machine learning-based nocturnal BP prediction using single-channel fingertip PPG in healthy adults. The accuracy of the predictions demonstrated that our cuffless method was able to capture the dynamic and complex relationship between PPG waveform characteristics and BP during sleep, which may provide a scalable, convenient, economical, and non-invasive means to continuously monitor blood pressure.
Open AccessNocturnal Blood Pressure Estimation from Sleep Plethysmography Using Machine Learning
Background: Elevated nocturnal blood pressure (BP) is a risk factor for cardiovascular disease (CVD) and mortality. Cuffless BP assessment aided by machine learning could be a desirable alternative to traditional cuff-based methods for monitoring BP during sleep. We describe a machine-learning-based algorithm for predicting nocturnal BP using single-channel fingertip plethysmography (PPG) in healthy adults. Methods: Sixty-eight healthy adults with no apparent sleep or CVD (53% male), with a median (IQR) age of 29 (23–46 years), underwent overnight polysomnography (PSG) with fingertip PPG and ambulatory blood pressure monitoring (ABPM). Features based on pulse morphology were extracted from the PPG waveforms. Random forest models were used to predict night-time systolic blood pressure (SBP) and diastolic blood pressure (DBP). Results: Our model achieved the highest out-of-sample performance with a window length of 7 s across window lengths explored (60 s, 30 s, 15 s, 7 s, and 3 s). The mean absolute error (MAE ± STD) was 5.72 ± 4.51 mmHg for SBP and 4.52 ± 3.60 mmHg for DBP. Similarly, the root mean square error (RMSE ± STD) was 6.47 ± 1.88 mmHg for SBP and 4.62 ± 1.17 mmHg for DBP. The mean correlation coefficient between measured and predicted values was 0.87 for SBP and 0.86 for DBP. Based on Shapley additive explanation (SHAP) values, the most important PPG waveform feature was the stiffness index, a marker that reflects the change in arterial stiffness. Conclusion: Our results highlight the potential of machine learning-based nocturnal BP prediction using single-channel fingertip PPG in healthy adults. The accuracy of the predictions demonstrated that our cuffless method was able to capture the dynamic and complex relationship between PPG waveform characteristics and BP during sleep, which may provide a scalable, convenient, economical, and non-invasive means to continuously monitor blood pressure.
- Open Access
- 28 June 2023
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 46 (10)
Insights into vascular physiology from sleep photoplethysmography
Study Objectives: Photoplethysmography (PPG) in consumer sleep trackers is now widely available and used to assess heart rate variability (HRV) for sleep staging. However, PPG waveform changes during sleep can also inform about vascular elasticity in healthy persons who constitute a majority of users. To assess its potential value, we traced the evolution of PPG pulse waveform during sleep alongside measurements of HRV and blood pressure (BP). Methods: Seventy-eight healthy adults (50% male, median [IQR range] age: 29.5 [23.0, 43.8]) underwent overnight polysomnography (PSG) with fingertip PPG, ambulatory blood pressure monitoring, and electrocardiography (ECG). Selected PPG features that reflect arterial stiffness: systolic to diastolic distance (∆T_norm), normalized rising slope (Rslope) and normalized reflection index (RI) were derived using a custom-built algorithm. Pulse arrival time (PAT) was calculated using ECG and PPG signals. The effect of sleep stage on these measures of arterial elasticity and how this pattern of sleep stage evolution differed with participant age were investigated. Results: BP, heart rate (HR) and PAT were reduced with deeper non-REM sleep but these changes were unaffected by the age range tested. After adjusting for lowered HR, ∆T_norm, Rslope, and RI showed significant effects of sleep stage, whereby deeper sleep was associated with lower arterial stiffness. Age was significantly correlated with the amount of sleep-related change in ∆T_norm, Rslope, and RI, and remained a significant predictor of RI after adjustment for sex, body mass index, office BP, and sleep efficiency. Conclusions: The current findings indicate that the magnitude of sleep-related change in PPG waveform can provide useful information about vascular elasticity and age effects on this in healthy adults.
- 28 June 2023
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 46 (10)
Open AccessInsights into vascular physiology from sleep photoplethysmography
Study Objectives: Photoplethysmography (PPG) in consumer sleep trackers is now widely available and used to assess heart rate variability (HRV) for sleep staging. However, PPG waveform changes during sleep can also inform about vascular elasticity in healthy persons who constitute a majority of users. To assess its potential value, we traced the evolution of PPG pulse waveform during sleep alongside measurements of HRV and blood pressure (BP). Methods: Seventy-eight healthy adults (50% male, median [IQR range] age: 29.5 [23.0, 43.8]) underwent overnight polysomnography (PSG) with fingertip PPG, ambulatory blood pressure monitoring, and electrocardiography (ECG). Selected PPG features that reflect arterial stiffness: systolic to diastolic distance (∆T_norm), normalized rising slope (Rslope) and normalized reflection index (RI) were derived using a custom-built algorithm. Pulse arrival time (PAT) was calculated using ECG and PPG signals. The effect of sleep stage on these measures of arterial elasticity and how this pattern of sleep stage evolution differed with participant age were investigated. Results: BP, heart rate (HR) and PAT were reduced with deeper non-REM sleep but these changes were unaffected by the age range tested. After adjusting for lowered HR, ∆T_norm, Rslope, and RI showed significant effects of sleep stage, whereby deeper sleep was associated with lower arterial stiffness. Age was significantly correlated with the amount of sleep-related change in ∆T_norm, Rslope, and RI, and remained a significant predictor of RI after adjustment for sex, body mass index, office BP, and sleep efficiency. Conclusions: The current findings indicate that the magnitude of sleep-related change in PPG waveform can provide useful information about vascular elasticity and age effects on this in healthy adults.
- Open Access
- 21 December 2022
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 6 (4) , 1-32
SleepMore
The availability of commercial wearable trackers equipped with features to monitor sleep duration and quality has enabled more useful sleep health monitoring applications and analyses. However, much research has reported the challenge of long-term user retention in sleep monitoring through these modalities. Since modern Internet users own multiple mobile devices, our work explores the possibility of employing ubiquitous mobile devices and passive WiFi sensing techniques to predict sleep duration as the fundamental measure for complementing long-term sleep monitoring initiatives. In this paper, we propose SleepMore, an accurate and easy-to-deploy sleep-tracking approach based on machine learning over the user's WiFi network activity. It first employs a semi-personalized random forest model with an infinitesimal jackknife variance estimation method to classify a user's network activity behavior into sleep and awake states per minute granularity. Through a moving average technique, the system uses these state sequences to estimate the user's nocturnal sleep period and its uncertainty rate. Uncertainty quantification enables SleepMore to overcome the impact of noisy WiFi data that can yield large prediction errors. We validate SleepMore using data from a month-long user study involving 46 college students and draw comparisons with the Oura Ring wearable. Beyond the college campus, we evaluate SleepMore on non-student users of different housing profiles. Our results demonstrate that SleepMore produces statistically indistinguishable sleep statistics from the Oura ring baseline for predictions made within a 5% uncertainty rate. These errors range between 15-28 minutes for determining sleep time and 7-29 minutes for determining wake time, proving statistically significant improvements over prior work. Our in-depth analysis explains the sources of errors.
- 21 December 2022
- Published by Association for Computing Machinery (ACM) in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
- Vol. 6 (4) , 1-32
Open AccessSleepMore
The availability of commercial wearable trackers equipped with features to monitor sleep duration and quality has enabled more useful sleep health monitoring applications and analyses. However, much research has reported the challenge of long-term user retention in sleep monitoring through these modalities. Since modern Internet users own multiple mobile devices, our work explores the possibility of employing ubiquitous mobile devices and passive WiFi sensing techniques to predict sleep duration as the fundamental measure for complementing long-term sleep monitoring initiatives. In this paper, we propose SleepMore, an accurate and easy-to-deploy sleep-tracking approach based on machine learning over the user's WiFi network activity. It first employs a semi-personalized random forest model with an infinitesimal jackknife variance estimation method to classify a user's network activity behavior into sleep and awake states per minute granularity. Through a moving average technique, the system uses these state sequences to estimate the user's nocturnal sleep period and its uncertainty rate. Uncertainty quantification enables SleepMore to overcome the impact of noisy WiFi data that can yield large prediction errors. We validate SleepMore using data from a month-long user study involving 46 college students and draw comparisons with the Oura Ring wearable. Beyond the college campus, we evaluate SleepMore on non-student users of different housing profiles. Our results demonstrate that SleepMore produces statistically indistinguishable sleep statistics from the Oura ring baseline for predictions made within a 5% uncertainty rate. These errors range between 15-28 minutes for determining sleep time and 7-29 minutes for determining wake time, proving statistically significant improvements over prior work. Our in-depth analysis explains the sources of errors.
- Open Access
- 1 April 2022
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 14, 645-660
Multi-Night at-Home Evaluation of Improved Sleep Detection and Classification with a Memory-Enhanced Consumer Sleep Tracker
Purpose: To evaluate the benefits of applying an improved sleep detection and staging algorithm on minimally processed multi-sensor wearable data collected from older generation hardware. Patients and Methods: 58 healthy, East Asian adults aged 23– 69 years (M = 37.10, SD = 13.03, 32 males), each underwent 3 nights of PSG at home, wearing 2nd Generation Oura Rings equipped with additional memory to store raw data from accelerometer, infra-red photoplethysmography and temperature sensors. 2-stage and 4-stage sleep classifications using a new machine-learning algorithm (Gen3) trained on a diverse and independent dataset were compared to the existing consumer algorithm (Gen2) for whole-night and epoch-by-epoch metrics. Results: Gen 3 outperformed its predecessor with a mean (SD) accuracy of 92.6% (0.04), sensitivity of 94.9% (0.03), and specificity of 78.5% (0.11); corresponding to a 3%, 2.8% and 6.2% improvement from Gen2 across the three nights, with Cohen’s d values > 0.39, t values > 2.69, and p values < 0.01. Notably, Gen 3 showed robust performance comparable to PSG in its assessment of sleep latency, light sleep, rapid eye movement (REM), and wake after sleep onset (WASO) duration. Participants < 40 years of age benefited more from the upgrade with less measurement bias for total sleep time (TST), WASO, light sleep and sleep efficiency compared to those ≥ 40 years. Males showed greater improvements on TST and REM sleep measurement bias compared to females, while females benefitted more for deep sleep measures compared to males. Conclusion: These results affirm the benefits of applying machine learning and a diverse training dataset to improve sleep measurement of a consumer wearable device. Importantly, collecting raw data with appropriate hardware allows for future advancements in algorithm development or sleep physiology to be retrospectively applied to enhance the value of longitudinal sleep studies.
- 1 April 2022
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 14, 645-660
Open AccessMulti-Night at-Home Evaluation of Improved Sleep Detection and Classification with a Memory-Enhanced Consumer Sleep Tracker
Purpose: To evaluate the benefits of applying an improved sleep detection and staging algorithm on minimally processed multi-sensor wearable data collected from older generation hardware. Patients and Methods: 58 healthy, East Asian adults aged 23– 69 years (M = 37.10, SD = 13.03, 32 males), each underwent 3 nights of PSG at home, wearing 2nd Generation Oura Rings equipped with additional memory to store raw data from accelerometer, infra-red photoplethysmography and temperature sensors. 2-stage and 4-stage sleep classifications using a new machine-learning algorithm (Gen3) trained on a diverse and independent dataset were compared to the existing consumer algorithm (Gen2) for whole-night and epoch-by-epoch metrics. Results: Gen 3 outperformed its predecessor with a mean (SD) accuracy of 92.6% (0.04), sensitivity of 94.9% (0.03), and specificity of 78.5% (0.11); corresponding to a 3%, 2.8% and 6.2% improvement from Gen2 across the three nights, with Cohen’s d values > 0.39, t values > 2.69, and p values < 0.01. Notably, Gen 3 showed robust performance comparable to PSG in its assessment of sleep latency, light sleep, rapid eye movement (REM), and wake after sleep onset (WASO) duration. Participants < 40 years of age benefited more from the upgrade with less measurement bias for total sleep time (TST), WASO, light sleep and sleep efficiency compared to those ≥ 40 years. Males showed greater improvements on TST and REM sleep measurement bias compared to females, while females benefitted more for deep sleep measures compared to males. Conclusion: These results affirm the benefits of applying machine learning and a diverse training dataset to improve sleep measurement of a consumer wearable device. Importantly, collecting raw data with appropriate hardware allows for future advancements in algorithm development or sleep physiology to be retrospectively applied to enhance the value of longitudinal sleep studies.
- 13 October 2016
- Published by Springer Nature
- p. 183-187
Jaw Reflexes Originating from the Periodontal and Muscle Spindle Receptors to the Jaw Muscles
- 13 October 2016
- Published by Springer Nature
- p. 183-187
Jaw Reflexes Originating from the Periodontal and Muscle Spindle Receptors to the Jaw Muscles