Sandeep Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sandeep Singh has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Surinder Pal Singh
CSIR-National Physical Laboratory, New Delhi, India
3 shared publications - Anuj Krishna
CSIR-National Physical Laboratory, New Delhi, India
2 shared publications - Asit Patra
Photovoltaic Metrology Section, Advanced Materials & Device Metrology Division, CSIR-National Physical Laboratory, Dr K. S. Krishnan Marg, New Delhi 110012, India
2 shared publications - Debabrata Nayak
S and H Department, Bharat Institute of Engineering and Technology, Hyderabad, India
2 shared publications - Manju Kumari
CSIR - National Physical Laboratory
2 shared publications - Nahar Singh
Chemical Metrology Group, Indian Reference Materials (BND) Division, CSIR-National Physical Laboratory, New Delhi, India
2 shared publications
Latest Publications
- 24 August 2023
- Published by Springer Nature
- p. 651-678
Indian Reference Materials for Calibration of Sophisticated Instruments
- 24 August 2023
- Published by Springer Nature
- p. 651-678
Indian Reference Materials for Calibration of Sophisticated Instruments
- Open Access
- 20 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 406
Clinically Deployable Bioelectronic Sensing Platform for Ultrasensitive Detection of Transferrin in Serum Sample
Varying levels of transferrin (Tf) have been associated with different disease conditions and are known to play a crucial role in various malignancies. Regular monitoring of the variations in Tf levels can be useful for managing related diseases, especially for the prognosis of certain cancers. We fabricated an immunosensor based on graphene oxide (GO) nanosheets to indirectly detect Tf levels in cancer patients. The GO nanosheets were deposited onto an indium tin oxide (ITO)-coated glass substrate and annealed at 120 °C to obtain reduced GO (rGO) films, followed by the immobilization of an antibody, anti-Tf. The materials and sensor probe used were systematically characterized by UV–Visible spectroscopy (UV–Vis), X-ray diffraction (XRD), atomic force microscopy (AFM), and Fourier transform infrared spectroscopy (FTIR). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) were also used for the stepwise sensor probe characterizations and Tf detection in serum samples, respectively. The anti-Tf/rGO/ITO immunosensor DPV output demonstrated an excellent Tf detection capability in the linear range of 0.1 mg mL−1 to 12 mg mL−1 compared to the enzyme-linked immunosorbent assay (ELISA) detection range, with a limit of detection (LOD) of 0.010 ± 0.007 mg mL−1. Furthermore, the results of the fabricated immunosensor were compared with those of the ELISA and autobioanalyzer techniques, showing an outstanding match with < 5% error and demonstrating the immunosensor’s clinical potential.
- 20 March 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (3) , 406
Open AccessClinically Deployable Bioelectronic Sensing Platform for Ultrasensitive Detection of Transferrin in Serum Sample
Varying levels of transferrin (Tf) have been associated with different disease conditions and are known to play a crucial role in various malignancies. Regular monitoring of the variations in Tf levels can be useful for managing related diseases, especially for the prognosis of certain cancers. We fabricated an immunosensor based on graphene oxide (GO) nanosheets to indirectly detect Tf levels in cancer patients. The GO nanosheets were deposited onto an indium tin oxide (ITO)-coated glass substrate and annealed at 120 °C to obtain reduced GO (rGO) films, followed by the immobilization of an antibody, anti-Tf. The materials and sensor probe used were systematically characterized by UV–Visible spectroscopy (UV–Vis), X-ray diffraction (XRD), atomic force microscopy (AFM), and Fourier transform infrared spectroscopy (FTIR). Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) were also used for the stepwise sensor probe characterizations and Tf detection in serum samples, respectively. The anti-Tf/rGO/ITO immunosensor DPV output demonstrated an excellent Tf detection capability in the linear range of 0.1 mg mL−1 to 12 mg mL−1 compared to the enzyme-linked immunosorbent assay (ELISA) detection range, with a limit of detection (LOD) of 0.010 ± 0.007 mg mL−1. Furthermore, the results of the fabricated immunosensor were compared with those of the ELISA and autobioanalyzer techniques, showing an outstanding match with < 5% error and demonstrating the immunosensor’s clinical potential.
- 1 January 2022
- Published by Springer Nature
- p. 1-28
Indian Reference Materials for Calibration of Sophisticated Instruments
- 1 January 2022
- Published by Springer Nature
- p. 1-28
Indian Reference Materials for Calibration of Sophisticated Instruments