Qian Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Qian Wu has a total of 135 co-authors. Here are the top co-authors by number of shared publications:
Guoliang Huang
5 shared publications- Tony Jun Huang
Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA
5 shared publications - Ying Chen
Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA
5 shared publications - Guoliang Huang
Peking University
4 shared publications - Kaichun Yang
Thomas Lord Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27708, USA
4 shared publications - Luke P. Lee
Renal Division and Division of Engineering in Medicine, Department of Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA
3 shared publications
Latest Publications
- 25 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (39)
Acoustofluidic cryo-EM enables in situ particle manipulation for uniform, high-quality cryo-EM specimens
Cryo–electron microscopy (cryo-EM) has revolutionized structural biology by enabling imaging of macromolecular complexes at near-atomic resolution, but its success depends critically on specimen quality. Standard plunge freezing often produces nonuniform particle distributions, resulting in poor particle statistics and reduced imaging quality, particularly for vesicular structures and low-concentration, labile macromolecular complexes. Here, we introduce acoustofluidic cryo-EM (ACE), a noncontact specimen-preparation method that integrates acoustofluidic manipulation into a conventional plunge-freezing workflow. ACE enables localized nanoscale particle manipulation by mechanically coupling acoustic excitation into the cryo-EM grid, where forced vibration generates localized acoustic streaming through viscous boundary-layer effects. Guided by this physical mechanism, validation using liposomes and apoferritin demonstrates that ACE increases particle density by up to fourfold while preserving structural integrity and improving imaging quality. This strategy provides a broadly applicable approach for enhancing cryo-EM specimen quality, improving imaging efficiency, and facilitating high-resolution structural analysis.
- 25 September 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (39)
Acoustofluidic cryo-EM enables in situ particle manipulation for uniform, high-quality cryo-EM specimens
Cryo–electron microscopy (cryo-EM) has revolutionized structural biology by enabling imaging of macromolecular complexes at near-atomic resolution, but its success depends critically on specimen quality. Standard plunge freezing often produces nonuniform particle distributions, resulting in poor particle statistics and reduced imaging quality, particularly for vesicular structures and low-concentration, labile macromolecular complexes. Here, we introduce acoustofluidic cryo-EM (ACE), a noncontact specimen-preparation method that integrates acoustofluidic manipulation into a conventional plunge-freezing workflow. ACE enables localized nanoscale particle manipulation by mechanically coupling acoustic excitation into the cryo-EM grid, where forced vibration generates localized acoustic streaming through viscous boundary-layer effects. Guided by this physical mechanism, validation using liposomes and apoferritin demonstrates that ACE increases particle density by up to fourfold while preserving structural integrity and improving imaging quality. This strategy provides a broadly applicable approach for enhancing cryo-EM specimen quality, improving imaging efficiency, and facilitating high-resolution structural analysis.
- Open Access
- 24 August 2026
- Published by Elsevier in SSRN Electronic Journal
Harnessing Self-sustained Skin Modes in Nonlinear Non-Hermitian Metastructures for Autonomous Robotic Locomotion
Active non-Hermitian metamaterials offer a powerful mechanism for organizing collective mechanical motion through directional amplification and skin localization; however, the resulting dynamical instability generally limits their direct application to autonomous locomotion. Here, we propose a nonlinear non-Hermitian metastructure in which mechanical nonlinearity regularizes the non-Hermitian instability and produces a bounded spatially asymmetric self-sustained dynamical state. For the periodic lattice, weakly nonlinear analysis reveals an intrinsic amplitude-dependent mechanism arising from the competition between non-Hermitian amplification and nonlinear regulation. In the corresponding finite autonomous system, active non-Hermitian coupling destabilizes the quiescent equilibrium through a Hopf bifurcation, while cubic nonlinearity saturates the ensuing instability and stabilizes a finite-amplitude, skin-localized limit cycle. When combined with direction-dependent friction, this self-sustained asymmetric oscillation is rectified into persistent crawling motion, whose direction and velocity can be controlled through modulation of the non-Hermitian coupling, further enabling programmable planar trajectory control. These findings establish a new mechanics-based paradigm for physically encoding gait generation, amplitude regulation, and locomotion control into the intrinsic dynamics of autonomous robotic systems.
- 24 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHarnessing Self-sustained Skin Modes in Nonlinear Non-Hermitian Metastructures for Autonomous Robotic Locomotion
Active non-Hermitian metamaterials offer a powerful mechanism for organizing collective mechanical motion through directional amplification and skin localization; however, the resulting dynamical instability generally limits their direct application to autonomous locomotion. Here, we propose a nonlinear non-Hermitian metastructure in which mechanical nonlinearity regularizes the non-Hermitian instability and produces a bounded spatially asymmetric self-sustained dynamical state. For the periodic lattice, weakly nonlinear analysis reveals an intrinsic amplitude-dependent mechanism arising from the competition between non-Hermitian amplification and nonlinear regulation. In the corresponding finite autonomous system, active non-Hermitian coupling destabilizes the quiescent equilibrium through a Hopf bifurcation, while cubic nonlinearity saturates the ensuing instability and stabilizes a finite-amplitude, skin-localized limit cycle. When combined with direction-dependent friction, this self-sustained asymmetric oscillation is rectified into persistent crawling motion, whose direction and velocity can be controlled through modulation of the non-Hermitian coupling, further enabling programmable planar trajectory control. These findings establish a new mechanics-based paradigm for physically encoding gait generation, amplitude regulation, and locomotion control into the intrinsic dynamics of autonomous robotic systems.
- Open Access
- 13 May 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (12) , 3617-3661
Integrated microfluidic biosensors: shaping the future of quantitative life sciences and on-chip molecular diagnostics
Integrated microfluidic biosensors have rapidly evolved into powerful platforms to meet the increasing demand for ultrasensitive and high-throughput quantitative analysis. By seamlessly combining sample handling through microfluidics with real-time detection via biosensors, these systems provide unmatched benefits in sensitivity, speed, portability, and immediate monitoring, thereby transforming diagnostics in human and animal health, environmental sensing, and point-of-care testing. In this review, we provide a comprehensive overview of integrated microfluidics with biosensors, highlighting the synergistic interplay between these two complementary fields and their various biomedical applications. We begin by examining different microfluidic technologies, including 3D dynamic cell culture systems, inertial microfluidic separation, acoustofluidics, dielectrophoresis, optofluidics, and immunoassays. Next, we discuss integrated microfluidic systems that incorporate various biosensor technologies, including electrochemical, electrophysiological, plasmonic, Raman, and quantum sensors. These are designed to detect and analyze DNA, RNA, proteins, exosomes, cells, and small organisms, covering a size range from nanometers to millimeters. Additionally, we discuss the wide range of applications for integrated microfluidic biosensors and examine significant challenges and future opportunities that will influence their ongoing development and practical use. Finally, we highlight successful commercial products developed with integrated microfluidic technologies.
- 13 May 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (12) , 3617-3661
Open AccessIntegrated microfluidic biosensors: shaping the future of quantitative life sciences and on-chip molecular diagnostics
Integrated microfluidic biosensors have rapidly evolved into powerful platforms to meet the increasing demand for ultrasensitive and high-throughput quantitative analysis. By seamlessly combining sample handling through microfluidics with real-time detection via biosensors, these systems provide unmatched benefits in sensitivity, speed, portability, and immediate monitoring, thereby transforming diagnostics in human and animal health, environmental sensing, and point-of-care testing. In this review, we provide a comprehensive overview of integrated microfluidics with biosensors, highlighting the synergistic interplay between these two complementary fields and their various biomedical applications. We begin by examining different microfluidic technologies, including 3D dynamic cell culture systems, inertial microfluidic separation, acoustofluidics, dielectrophoresis, optofluidics, and immunoassays. Next, we discuss integrated microfluidic systems that incorporate various biosensor technologies, including electrochemical, electrophysiological, plasmonic, Raman, and quantum sensors. These are designed to detect and analyze DNA, RNA, proteins, exosomes, cells, and small organisms, covering a size range from nanometers to millimeters. Additionally, we discuss the wide range of applications for integrated microfluidic biosensors and examine significant challenges and future opportunities that will influence their ongoing development and practical use. Finally, we highlight successful commercial products developed with integrated microfluidic technologies.
- Open Access
- 1 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (18) , eaee2983
Space-time acoustofluidic tweezers for dynamic and selective manipulation of microparticles
Dynamic acoustofluidics enables precise, contact-free manipulation of particles, colloids, and cells and shows great potential for applications in physics, materials science, and life sciences. However, existing strategies struggle to realize contrast-based selective manipulation primarily because the pressure fields are time invariant. Here, we introduce a space-time acoustofluidic tweezer (STAT) that uses frequency detuning–induced pseudo–space-time modulation of standing surface acoustic waves to enable dynamic, contrast-dependent control of microparticles and cells. Experiments and simulations show that, under STAT manipulation, positive (PACP) and negative (NACP) acoustic contrast particles can undergo low-frequency, shear- and longitudinal-like harmonic motions, respectively. Under certain driving conditions, NACPs can be selectively guided along programmed paths, whereas PACPs remain stably patterned. Overall, STAT offers a gentle, biocompatible way to selectively drive oscillation, transport, and sorting among particles and cells of different acoustic contrasts, broadening the capabilities of acoustofluidic systems for biomedical applications.
- 1 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (18) , eaee2983
Open AccessSpace-time acoustofluidic tweezers for dynamic and selective manipulation of microparticles
Dynamic acoustofluidics enables precise, contact-free manipulation of particles, colloids, and cells and shows great potential for applications in physics, materials science, and life sciences. However, existing strategies struggle to realize contrast-based selective manipulation primarily because the pressure fields are time invariant. Here, we introduce a space-time acoustofluidic tweezer (STAT) that uses frequency detuning–induced pseudo–space-time modulation of standing surface acoustic waves to enable dynamic, contrast-dependent control of microparticles and cells. Experiments and simulations show that, under STAT manipulation, positive (PACP) and negative (NACP) acoustic contrast particles can undergo low-frequency, shear- and longitudinal-like harmonic motions, respectively. Under certain driving conditions, NACPs can be selectively guided along programmed paths, whereas PACPs remain stably patterned. Overall, STAT offers a gentle, biocompatible way to selectively drive oscillation, transport, and sorting among particles and cells of different acoustic contrasts, broadening the capabilities of acoustofluidic systems for biomedical applications.
- 4 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (9) , 096101
Physical Realization of an Anti- P -Pseudo-Hermitian Mechanical System
The anti-P-pseudo-Hermitian system has recently been recognized as a new avenue in non-Hermitian physics, exhibiting symmetry-related phenomena without the need for time-reversal symmetry. However, its physical realization remains challenging due to the difficulty of integrating tunable media while simultaneously enabling nonreciprocal coupling. In this Letter, we introduce a novel framework for constructing an anti-P-pseudo-Hermitian mechanical system by incorporating piezoelectric actuators and sensors with nonreciprocal coupling into mechanical beams. We theoretically demonstrate that this system can exhibit programmable exceptional points (EPs) and validate our approach numerically and experimentally. Precise tuning of EPs is crucial for optimizing the system's sensitivity under operational conditions. As a key demonstration, we show that this system excels in detecting minute mass variations, making it highly effective for ultrasensitive sensing applications. This Letter not only advances the understanding of non-Hermitian physics, but also lays the groundwork for the next generation of mechanical sensors based on EP physics.
- 4 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (9) , 096101
Physical Realization of an Anti- P -Pseudo-Hermitian Mechanical System
The anti-P-pseudo-Hermitian system has recently been recognized as a new avenue in non-Hermitian physics, exhibiting symmetry-related phenomena without the need for time-reversal symmetry. However, its physical realization remains challenging due to the difficulty of integrating tunable media while simultaneously enabling nonreciprocal coupling. In this Letter, we introduce a novel framework for constructing an anti-P-pseudo-Hermitian mechanical system by incorporating piezoelectric actuators and sensors with nonreciprocal coupling into mechanical beams. We theoretically demonstrate that this system can exhibit programmable exceptional points (EPs) and validate our approach numerically and experimentally. Precise tuning of EPs is crucial for optimizing the system's sensitivity under operational conditions. As a key demonstration, we show that this system excels in detecting minute mass variations, making it highly effective for ultrasensitive sensing applications. This Letter not only advances the understanding of non-Hermitian physics, but also lays the groundwork for the next generation of mechanical sensors based on EP physics.
- Top Cited PapersOpen Access
- 2 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (1) , eady1136
Precision acoustofluidics for high-throughput mechanobiology in suspension cells
Mechanomodulation, the process of altering cellular behavior through applied mechanical forces, plays a critical role in physiological processes and has substantial implications for cancer therapy, immunology, and drug development. However, precise and efficient stimulation of nonadherent cells remains a major challenge, limiting the investigation of mechanotransduction pathways and the development of targeted therapeutics. Here, we developed an acoustofluidic platform named Suspension-cell Targeted Response to Excitation via Acoustofluidic Mechanomodulation (STREAM) to enable precise, high-throughput stimulation of suspension cells. STREAM accomplishes this using 101.14-megahertz high-frequency surface acoustic waves to deliver controlled mechanical stimulation at a throughput of 500,000 cells per minute. STREAM modulates intracellular calcium ion (Ca 2+ ) signaling by activating mechanosensitive ion channels, triggering mitochondrial membrane disruption and tunable K562 leukemia cell apoptosis rates from 5.15 to 47.1%. STREAM provides a scalable, precise tool for studying mechanotransduction in suspension cells, with broad applications in cancer research, immunotherapy, and high-throughput drug screening.
- 2 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (1) , eady1136
Top Cited PapersOpen AccessPrecision acoustofluidics for high-throughput mechanobiology in suspension cells
Mechanomodulation, the process of altering cellular behavior through applied mechanical forces, plays a critical role in physiological processes and has substantial implications for cancer therapy, immunology, and drug development. However, precise and efficient stimulation of nonadherent cells remains a major challenge, limiting the investigation of mechanotransduction pathways and the development of targeted therapeutics. Here, we developed an acoustofluidic platform named Suspension-cell Targeted Response to Excitation via Acoustofluidic Mechanomodulation (STREAM) to enable precise, high-throughput stimulation of suspension cells. STREAM accomplishes this using 101.14-megahertz high-frequency surface acoustic waves to deliver controlled mechanical stimulation at a throughput of 500,000 cells per minute. STREAM modulates intracellular calcium ion (Ca 2+ ) signaling by activating mechanosensitive ion channels, triggering mitochondrial membrane disruption and tunable K562 leukemia cell apoptosis rates from 5.15 to 47.1%. STREAM provides a scalable, precise tool for studying mechanotransduction in suspension cells, with broad applications in cancer research, immunotherapy, and high-throughput drug screening.
- Open Access
- 5 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (36) , eady3262
Acoustofluidic system for targeted antibody removal in transplantation: Enabling small-volume therapeutic apheresis
Antibody-mediated rejection is a leading cause of allograft failure and mortality in pediatric solid organ transplant recipients. Current apheresis systems require large blood volumes and are primarily designed for adults, making them unsuitable for children and small animals. These systems often indiscriminately remove both harmful and protective antibodies, increasing the risk of complications such as life-threatening infections. To address this critical need, we developed acoustofluidic-based system for targeted antibody removal in transplantation (A-START). A-START is engineered to handle small blood volumes and has demonstrated efficacy in preclinical small animal trials. In a sensitized rodent skin transplantation model, A-START only demands 240 microliters of blood, selectively removing donor-specific alloantibodies (DSAs) while preserving protective antibodies, such as tetanus antibodies. A-START retains ~95% of beneficial antibodies and achieves a 60% improvement in DSA removal compared to conventional methods. These findings highlight the transformative potential of A-START as a promising, reliable, scalable solution for improving outcomes in pediatric transplantation and treating antibody-mediated diseases.
- 5 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (36) , eady3262
Open AccessAcoustofluidic system for targeted antibody removal in transplantation: Enabling small-volume therapeutic apheresis
Antibody-mediated rejection is a leading cause of allograft failure and mortality in pediatric solid organ transplant recipients. Current apheresis systems require large blood volumes and are primarily designed for adults, making them unsuitable for children and small animals. These systems often indiscriminately remove both harmful and protective antibodies, increasing the risk of complications such as life-threatening infections. To address this critical need, we developed acoustofluidic-based system for targeted antibody removal in transplantation (A-START). A-START is engineered to handle small blood volumes and has demonstrated efficacy in preclinical small animal trials. In a sensitized rodent skin transplantation model, A-START only demands 240 microliters of blood, selectively removing donor-specific alloantibodies (DSAs) while preserving protective antibodies, such as tetanus antibodies. A-START retains ~95% of beneficial antibodies and achieves a 60% improvement in DSA removal compared to conventional methods. These findings highlight the transformative potential of A-START as a promising, reliable, scalable solution for improving outcomes in pediatric transplantation and treating antibody-mediated diseases.
- 19 April 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 296
Dissipative locally resonant metasurfaces for low-frequency Rayleigh wave mitigation
- 19 April 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 296
Dissipative locally resonant metasurfaces for low-frequency Rayleigh wave mitigation
- 29 March 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 293
Observation of multi-type corner states in right-angled trapezoidal sonic crystals
- 29 March 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 293
Observation of multi-type corner states in right-angled trapezoidal sonic crystals