XXXiangyang Xu

Xiangyang Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiangyang Xu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Guosheng Yi

    School of Electrical and Information Engineering, Tianjin University, Tianjin, China

    2 shared publications
  • Bin Deng

    School of Electrical and Information Engineering, Tianjin University , Tianjin, CHINA

    1 shared publication
  • Bin Deng

    School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China

    1 shared publication
  • Guo C Chen

    Beijing Key Laboratory of Intelligent Emergency Medical Rescue, Tiangong University, Tiangong University, Tianjin, 300387, CHINA

    1 shared publication
  • Hui Q Wang

    Beijing Key Laboratory of Intelligent Emergency Medical Rescue, Tiangong University, Tiangong University, Tianjin, 300387, CHINA

    1 shared publication
  • Jiang Wang

    School of Electrical and Information Engineering, Tianjin University , Tianjin, CHINA

    1 shared publication

Latest Publications

  • A magnetic induction–based differential method for intracerebral hemorrhage lateralization

    by Hui Q Wang, Guo C Chen, Rui J Chen, Xin Ma, Jin H Wang, Xiangyang Xu

    Magnetic induction technology (MIT), as a non-contact and non-invasive sensing approach, has shown great potential for detecting brain lesions since it is unaffected by skull shielding. However, most MIT-based studies on intracerebral hemorrhage (ICH) have mainly focused on identifying the presence or estimating the volume of bleeding, while research on spatial localization has remained limited. In this study, a magnetic induction differential localization (MIDL) method was proposed to detect and localize ICH. A pair of symmetrically arranged detection coils was designed to sense the differential magnetic field perturbations caused by variations in the electrical conductivity and permittivity of brain tissues. The feasibility and response characteristics of the system were verified through numerical simulations and physical phantom experiments, followed by in vivo validation on eight New Zealand white rabbits with unilateral induced hemorrhages. The real and imaginary components of the differential signals were analyzed to investigate their correlation with the side and volume of hemorrhage. Both simulations and phantom experiments demonstrated opposite variation trends of the real and imaginary components for left-and right-side hemorrhages. Animal experiments further confirmed that, after the injection of 1 mL of blood, the signal variation amplitudes significantly exceeded the baseline deviation (P < 0.05), exhibiting opposite directions of change between the two hemispheres. These results indicate that the proposed MIDL method can effectively distinguish the hemorrhage side and provide a theoretical and experimental foundation for non-invasive localization of intracerebral hemorrhage using MIT.

  • Open Access

    Individual Prediction of Electric Field Induced by Deep-Brain Magnetic Stimulation With CNN-Transformer

    by Xiangyang Xu, Bin Deng, Jiang Wang, Guosheng Yi

    Deep-brain Magnetic Stimulation (DMS) can improve the symptoms caused by Alzheimer’s disease by inducing rhythmic electric field in the deep brain, and the induced electric field is rhythm-dependent. However, calculating the induced electric field requires building a voxel model of the brain for the stimulated object, which usually takes several hours. In order to obtain the rhythm-dependent electric field induced by DMS in real time, we adopt a CNN-Transformer model to predict it. A data set with a sample size of 7350 is established for the training and testing of the model. 10-fold cross validation is used to determine the optimal hyperparameters for training CNN-Transformer. The combination of 5-layer CNN and 6-layer Transformer is verified as the optimal combination of CNN-Transformer model. The experimental results show that the CNN-Transformer model can complete the prediction in 0.731s (CPU) or 0.042s (GPU), and the overall performance metrics of prediction can reach: MAE =0.0269, RMSE =0.0420, MAPE =4.61% and R2 =0.9627. The prediction performance of the CNN-Transformer model for the hippocampal electric field is better than that of the brain grey matter electric field, and the stimulation rhythm has less influence on the model performance than the coil configuration. Taking the same dataset to train and test the separate CNN model and Transformer model, it is found that CNN-Transformer has better prediction performance than the separate CNN model and Transformer model in the task of predicting electric field induced by DMS.


  • Open Access

    Effect of stimulation frequency on hippocampal electric field induced by deep-brain magnetic stimulation

    by Xiang-Yang Xu, Bin Deng, Jiang Wang, Guo-Sheng Yi

    Deep-brain Magnetic Stimulation (DMS) is a noninvasive brain modulation method that improves hippocampal neural activity. The frequency of DMS has a significant effect on the hippocampal induced electric field. In this paper, we investigate the relationship between stimulation frequency and DMS-induced hippocampal electric field. The frequency sensitivity and distribution uniformity of the hippocampal electric field are calculated to quantify this relationship. The results show that the DMS-induced hippocampal electric field has a frequency-dependent property. The frequency sensitivity of the DMS-induced hippocampal electric field in the high frequency band is lower than that in the low frequency band, which corresponds to the low-pass filtering property of the neuron membrane. The frequency sensitivity of DMS-induced hippocampal electric field is highest in the range of 30–40 Hz. The uniformity of the hippocampal electric field induced by a single coil also reaches the highest in the range of 30–40 Hz, while uniformity of the hippocampal electric field induced by multiple-coil increases with increasing frequency. The frequency-dependent property of the DMS-induced hippocampal electric field is positively correlated with the quantity and size of coils, while negatively correlated with the spacing of the coils. This study is of great help in the selection of DMS frequencies and the design of coils.


  • Online Detection of Aircraft ARINC Bus Cable Fault Based on SSTDR

    by Xudong Shi, Yang Liu, Xiangyang Xu, Tao Jing

    In order to realize the online detection of ARINC bus cable fault, a method of spread spectrum time-domain reflectometry (SSTDR) is proposed in this article, which can minimize the influence between the ARINC bus signal and incident signal, and meet the requirements of aircraft airworthiness. First, the impedance characteristics and reflection characteristics of the aircraft ARINC bus cables are analyzed so that the online detection model based on SSTDR is constructed. Then, the SSTDR incident signal is designed by studying the relationship between the incident signal parameters and the ARINC bus characteristics. Finally, the proposed method is verified through the online detection platform of ARINC 429/825 bus cable fault, and the experimental signals are analyzed in the time domain and the frequency domain, respectively, which indicates that the ARINC bus signal and the incident signal do not interfere with each other. The experimental results prove that the method of SSTDR is effective and feasible to the online detection of ARINC bus cable fault.