Chenzhang Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Chenzhang Xiao has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Elizabeth T. Hsiao-Wecksler
Department of Mechanical Science & Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
3 shared publications - Brooke A. Slavens
Department of Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, USA
2 shared publications - Omid Jahanian
Mayo Clinic
2 shared publications - Adam W. Bleakney
University of Illinois Urbana-Champaign
1 shared publication - Alyssa J. Schnorenberg
University of Wisconsin-Milwaukee, Milwaukee, WI, USA
1 shared publication - Deana McDonagh
Beckman Institute for Advanced Science and Technology, University of Illinois Urbana-Champaign, Champaign, Illinois, USA
1 shared publication
Latest Publications
- Open Access
- 11 March 2024
- Published by Association for Computing Machinery (ACM)
- p. 678-686
Driving a Ballbot Wheelchair with Hands-Free Torso Control
A novel wheelchair called PURE (Personalized Unique Rolling Experience) that uses hands-free (HF) torso lean-to-steer control has been developed for manual wheelchair users (mWCUs). PURE addresses limitations of current wheelchairs, such as the inability to use both hands for life experiences instead of propulsion. PURE uses a ball-based robot drivetrain to offer a compact, self-balancing, omnidirectional mobile device. A custom sensor system converts rider torso motions into direction and speed commands to control PURE, which is especially useful if a rider has minimal torso range of motion. We explored whether PURE's HF control performed as well as a traditional joystick (JS) human-robot interface and mWCUs, who may have reduced torso motion, performed as well as able-bodied users (ABUs). 10 mWCUs and 10 ABUs were trained and tested to drive PURE through courses replicating indoor environments. Each participant adjusted personal sensitivity settings for both HF and JS control. Repeated-measures MANOVA tests suggested that the effectiveness (number of collisions), efficiency (completion time), comfort (NASA TLX scores except physical demand), and robustness (index of performances) were similar for HF and JS control and between mWCUs and ABUs for all sections. These results suggest that PURE provides an effective method for controlling this new omnidirectional wheelchair by only using torso motion thus leaving both hands to be used for other tasks during propulsion.
- 11 March 2024
- Published by Association for Computing Machinery (ACM)
- p. 678-686
Open AccessDriving a Ballbot Wheelchair with Hands-Free Torso Control
A novel wheelchair called PURE (Personalized Unique Rolling Experience) that uses hands-free (HF) torso lean-to-steer control has been developed for manual wheelchair users (mWCUs). PURE addresses limitations of current wheelchairs, such as the inability to use both hands for life experiences instead of propulsion. PURE uses a ball-based robot drivetrain to offer a compact, self-balancing, omnidirectional mobile device. A custom sensor system converts rider torso motions into direction and speed commands to control PURE, which is especially useful if a rider has minimal torso range of motion. We explored whether PURE's HF control performed as well as a traditional joystick (JS) human-robot interface and mWCUs, who may have reduced torso motion, performed as well as able-bodied users (ABUs). 10 mWCUs and 10 ABUs were trained and tested to drive PURE through courses replicating indoor environments. Each participant adjusted personal sensitivity settings for both HF and JS control. Repeated-measures MANOVA tests suggested that the effectiveness (number of collisions), efficiency (completion time), comfort (NASA TLX scores except physical demand), and robustness (index of performances) were similar for HF and JS control and between mWCUs and ABUs for all sections. These results suggest that PURE provides an effective method for controlling this new omnidirectional wheelchair by only using torso motion thus leaving both hands to be used for other tasks during propulsion.
- Open Access
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 789-797
Biomechanical Evaluation of Pneumatic Sleeve Orthosis for Lofstrand Crutches
Crutch walking, especially when using a swing-through gait pattern, is associated with high, repetitive joint forces, hyperextension/ulnar deviation of the wrist, and excessive palmar pressure that compresses the median nerve. To reduce these adverse effects, we designed a pneumatic sleeve orthosis that utilized a soft pneumatic actuator and secured to the crutch cuff for long-term Lofstrand crutch users. Eleven able-bodied young adult participants performed both swing-through and reciprocal crutch gait patterns with and without the custom orthosis for comparison. Wrist kinematics, crutch forces, and palmar pressures were analyzed. Significantly different wrist kinematics, crutch kinetics, and palmar pressure distribution were observed in swing-through gait trials with orthosis use (p<0.001, p=0.01, p=0.03, respectively). Reductions in peak and mean wrist extension (7%, 6%), wrist range of motion (23%), and peak and mean ulnar deviation (26%, 32%) indicate improved wrist posture. Significantly increased peak and mean crutch cuff forces suggest increased load sharing between the forearm and cuff. Reduced peak and mean palmar pressures (8%, 11%) and shifted peak palmar pressure location toward the adductor pollicis denote a redirection of pressure away from the median nerve. In reciprocal gait trials, non-significant but similar trends were observed in wrist kinematics and palmar pressure distribution, whereas a significant effect of load sharing was noticed (p=0.01). These results suggest that Lofstrand crutches modified with orthosis may improve wrist posture, reduce wrist and palmar load, redirect palmar pressure away from the median nerve, and thus may reduce or prevent the onset of wrist injuries.
- 12 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 789-797
Open AccessBiomechanical Evaluation of Pneumatic Sleeve Orthosis for Lofstrand Crutches
Crutch walking, especially when using a swing-through gait pattern, is associated with high, repetitive joint forces, hyperextension/ulnar deviation of the wrist, and excessive palmar pressure that compresses the median nerve. To reduce these adverse effects, we designed a pneumatic sleeve orthosis that utilized a soft pneumatic actuator and secured to the crutch cuff for long-term Lofstrand crutch users. Eleven able-bodied young adult participants performed both swing-through and reciprocal crutch gait patterns with and without the custom orthosis for comparison. Wrist kinematics, crutch forces, and palmar pressures were analyzed. Significantly different wrist kinematics, crutch kinetics, and palmar pressure distribution were observed in swing-through gait trials with orthosis use (p<0.001, p=0.01, p=0.03, respectively). Reductions in peak and mean wrist extension (7%, 6%), wrist range of motion (23%), and peak and mean ulnar deviation (26%, 32%) indicate improved wrist posture. Significantly increased peak and mean crutch cuff forces suggest increased load sharing between the forearm and cuff. Reduced peak and mean palmar pressures (8%, 11%) and shifted peak palmar pressure location toward the adductor pollicis denote a redirection of pressure away from the median nerve. In reciprocal gait trials, non-significant but similar trends were observed in wrist kinematics and palmar pressure distribution, whereas a significant effect of load sharing was noticed (p=0.01). These results suggest that Lofstrand crutches modified with orthosis may improve wrist posture, reduce wrist and palmar load, redirect palmar pressure away from the median nerve, and thus may reduce or prevent the onset of wrist injuries.
- Open Access
- 10 April 2017
- Published by ASME International
Design and Biomechanical Evaluation Methodology of Pneumatic Ergonomic Crutch
Lofstrand, or forearm, crutch users experience a concerning amount of force in their wrists that can approach 30% of body weight during swing-through gait, along with hyperextension of the wrist [1]. Such repetitive large loads and poor wrist posture could cause joint pain, injury and carpal tunnel syndrome in long-term crutch users [2]. To address these issues in Lofstrand crutch users, we previously reported two different designs. The first involved attaching a passive orthosis to the grip handle and shaft that directly supported the wrist [3]. The second proposed a soft pneumatic sleeve attached to the forearm cuff of the crutch along with a concept to harvest pneumatic energy during walking via a piston pump at the crutch tip, i.e., the Pneumatic Ergonomic Crutch (PEC) [4]. This paper first describes the full system design of the PEC, which contains an improved pneumatic sleeve orthosis, an energy-harvesting shock-absorbing crutch tip, and a control system with three modes of operation and safety protection. We also present pilot data from one healthy control subject performing a proposed biomechanical evaluation of the pneumatic sleeve orthosis. More tests will be conducted with a group of able-bodied subjects to evaluate the overall effectiveness of the PEC.
- 10 April 2017
- Published by ASME International
Open AccessDesign and Biomechanical Evaluation Methodology of Pneumatic Ergonomic Crutch
Lofstrand, or forearm, crutch users experience a concerning amount of force in their wrists that can approach 30% of body weight during swing-through gait, along with hyperextension of the wrist [1]. Such repetitive large loads and poor wrist posture could cause joint pain, injury and carpal tunnel syndrome in long-term crutch users [2]. To address these issues in Lofstrand crutch users, we previously reported two different designs. The first involved attaching a passive orthosis to the grip handle and shaft that directly supported the wrist [3]. The second proposed a soft pneumatic sleeve attached to the forearm cuff of the crutch along with a concept to harvest pneumatic energy during walking via a piston pump at the crutch tip, i.e., the Pneumatic Ergonomic Crutch (PEC) [4]. This paper first describes the full system design of the PEC, which contains an improved pneumatic sleeve orthosis, an energy-harvesting shock-absorbing crutch tip, and a control system with three modes of operation and safety protection. We also present pilot data from one healthy control subject performing a proposed biomechanical evaluation of the pneumatic sleeve orthosis. More tests will be conducted with a group of able-bodied subjects to evaluate the overall effectiveness of the PEC.