Yiping Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yiping Dong has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Pintong Huang
Department of Ultrasound in Medicine, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China
2 shared publications - Chao Zhang
Department of Ultrasound in Medicine, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang 310000, China
1 shared publication - Chen Qiu
Department of Ultrasound Medicine, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou 310009, China
1 shared publication - Chenchen He
Department of Radiation Oncology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
1 shared publication Cheng-Xian Ma
Department of Oncology, The Second Affiliated Hospital of Xi'an Jiaotong University Medical College, Xi’an, Shannxi, P.R. China
1 shared publication- Clifford Mason
Department of Obstetrics and Gynecology, University of Kansas School of Medicine, Kansas City, Kansas, USA
1 shared publication
Latest Publications
- Open Access
- 26 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (9) , 1547
Technical Acoustic Measurements Combined with Clinical Parameters for the Differential Diagnosis of Nonalcoholic Steatohepatitis
Background and aim: Diagnosing nonalcoholic steatohepatitis (NASH) is challenging. This study intended to explore the diagnostic value of multiple technical acoustic measurements in the diagnosis of NASH, and to establish a diagnostic model combining technical acoustic measurements with clinical parameters to improve the diagnostic efficacy of NASH. Methods: We consecutively enrolled 75 patients with clinically suspected nonalcoholic fatty liver disease (NAFLD) who underwent percutaneous liver biopsy in our hospital from June 2020 to December 2021. All cases underwent multiple advanced acoustic measurements for liver such as shear wave dispersion (SWD), shear wave speed (SWS), attenuation imaging (ATI), normalized local variance (NLV), and liver–kidney intensity ratio (Ratio) examination before liver biopsies. A nomogram prediction model combining the technical acoustic measurements and clinical parameters was established and the model is proposed to improve the diagnostic performance of NASH. Results: A total of 75 cases were included in this study. The classification of pathological grade for NASH was as follows: normal liver, (n = 15, 20%), nonalcoholic fatty liver (NAFL), (n = 44, 58.7%), and NASH, (n = 16, 21.3%). There were statistically significant differences in SWS (p = 0.002), acoustic coefficient (AC) (p = 0.018), NLV (p = 0.033), age (p = 0.013) and fasting blood glucose (Glu) (p = 0.049) between NASH and non-NASH. A nomogram model which includes SWS, AC, NLV, age and Glu was built to predict NASH, and the calibration curves showed good calibrations in both training and validation sets. The AUCs of the combined nomogram model for the training set and validation set were 0.8597 and 0.7794, respectively. Conclusion: There were statistically significant differences in SWS, AC, NLV, age and Glu between NASH and non-NASH. A nomogram model which includes SWS, AC, NLV, age and Glu was built to predict NASH. The predictive model has a higher diagnostic performance than a single factor model in the diagnosis of NASH and has good clinical application prospects.
- 26 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (9) , 1547
Open AccessTechnical Acoustic Measurements Combined with Clinical Parameters for the Differential Diagnosis of Nonalcoholic Steatohepatitis
Background and aim: Diagnosing nonalcoholic steatohepatitis (NASH) is challenging. This study intended to explore the diagnostic value of multiple technical acoustic measurements in the diagnosis of NASH, and to establish a diagnostic model combining technical acoustic measurements with clinical parameters to improve the diagnostic efficacy of NASH. Methods: We consecutively enrolled 75 patients with clinically suspected nonalcoholic fatty liver disease (NAFLD) who underwent percutaneous liver biopsy in our hospital from June 2020 to December 2021. All cases underwent multiple advanced acoustic measurements for liver such as shear wave dispersion (SWD), shear wave speed (SWS), attenuation imaging (ATI), normalized local variance (NLV), and liver–kidney intensity ratio (Ratio) examination before liver biopsies. A nomogram prediction model combining the technical acoustic measurements and clinical parameters was established and the model is proposed to improve the diagnostic performance of NASH. Results: A total of 75 cases were included in this study. The classification of pathological grade for NASH was as follows: normal liver, (n = 15, 20%), nonalcoholic fatty liver (NAFL), (n = 44, 58.7%), and NASH, (n = 16, 21.3%). There were statistically significant differences in SWS (p = 0.002), acoustic coefficient (AC) (p = 0.018), NLV (p = 0.033), age (p = 0.013) and fasting blood glucose (Glu) (p = 0.049) between NASH and non-NASH. A nomogram model which includes SWS, AC, NLV, age and Glu was built to predict NASH, and the calibration curves showed good calibrations in both training and validation sets. The AUCs of the combined nomogram model for the training set and validation set were 0.8597 and 0.7794, respectively. Conclusion: There were statistically significant differences in SWS, AC, NLV, age and Glu between NASH and non-NASH. A nomogram model which includes SWS, AC, NLV, age and Glu was built to predict NASH. The predictive model has a higher diagnostic performance than a single factor model in the diagnosis of NASH and has good clinical application prospects.
- 12 January 2023
- Published by Springer Nature in Journal of Ultrasound
- Vol. 26 (1) , 1-9
Correlation between ultrasonographic scores and American college of rheumatology recommended rheumatoid arthritis disease activity measures: a systematic review and network meta-analysis
Background To validate and facilitate ultrasound examinations on rheumatoid arthritis (RA) disease activity measurements in routine clinical practice. Methods A systematic review and network meta-analysis (NMA) of ultrasound examinations on joints and its correlation with clinical RA disease activity was performed. PubMed, Embase and Cochrane library were searched for literatures published up to May 01st 2021. Bayesian random-effect NMA was conducted to pool the correlations of ultrasonographic assessment scores with composite RA disease activity measurements. Results Fifteen studies evaluating twelve different existing ultrasonographic measurements on joints evaluation for RA disease activity scoring were included in this NMA. For comparisons with clinical disease activity index and simplified disease activity index, synovitis gray scale ultrasound 7 joints (GSUS7) demonstrated modest correlation of 0.30[− 0.74, 1.23] and 0.46[− 0.45, 1.15] respectively, followed by synovitis power Doppler ultrasound 7 joints (PDUS7) (0.25[− 0.57, 1.14], 0.31[− 0.46, 1.24]) and power Doppler ultrasound 12 joints (PDUS12) (0.23[− 1.36, 0.83], 0.25[− 1.18, 0.88]). As for disease activity score using 28 joint counts, PDUS12 showed the biggest correlation of 0.53[− 0.09, 1.11], followed by ultrasound 7 joints (US7) (0.50[0.06, 0.93]), PDUS7 (0.49[− 0.24, 1.12]), power Doppler ultrasound 6 joints (PDUS6) (0.42[− 0.29, 1.21]), synovitis PDUS7 (0.47[− 0.09, 1.27]) and synovitis GSUS7 (0.40[0.01, 0.86]). Conclusion Comparative validity was observed on fewer joints ultrasonic evaluation for RA disease activity measurements, such as synovitis GSUS7 and synovitis PDUS7. Ultrasonographic measurements can be complementary for clinical RA disease activity measures with clinical efficiency, and technical guidelines were in need for clinical routine practice.
- 12 January 2023
- Published by Springer Nature in Journal of Ultrasound
- Vol. 26 (1) , 1-9
Correlation between ultrasonographic scores and American college of rheumatology recommended rheumatoid arthritis disease activity measures: a systematic review and network meta-analysis
Background To validate and facilitate ultrasound examinations on rheumatoid arthritis (RA) disease activity measurements in routine clinical practice. Methods A systematic review and network meta-analysis (NMA) of ultrasound examinations on joints and its correlation with clinical RA disease activity was performed. PubMed, Embase and Cochrane library were searched for literatures published up to May 01st 2021. Bayesian random-effect NMA was conducted to pool the correlations of ultrasonographic assessment scores with composite RA disease activity measurements. Results Fifteen studies evaluating twelve different existing ultrasonographic measurements on joints evaluation for RA disease activity scoring were included in this NMA. For comparisons with clinical disease activity index and simplified disease activity index, synovitis gray scale ultrasound 7 joints (GSUS7) demonstrated modest correlation of 0.30[− 0.74, 1.23] and 0.46[− 0.45, 1.15] respectively, followed by synovitis power Doppler ultrasound 7 joints (PDUS7) (0.25[− 0.57, 1.14], 0.31[− 0.46, 1.24]) and power Doppler ultrasound 12 joints (PDUS12) (0.23[− 1.36, 0.83], 0.25[− 1.18, 0.88]). As for disease activity score using 28 joint counts, PDUS12 showed the biggest correlation of 0.53[− 0.09, 1.11], followed by ultrasound 7 joints (US7) (0.50[0.06, 0.93]), PDUS7 (0.49[− 0.24, 1.12]), power Doppler ultrasound 6 joints (PDUS6) (0.42[− 0.29, 1.21]), synovitis PDUS7 (0.47[− 0.09, 1.27]) and synovitis GSUS7 (0.40[0.01, 0.86]). Conclusion Comparative validity was observed on fewer joints ultrasonic evaluation for RA disease activity measurements, such as synovitis GSUS7 and synovitis PDUS7. Ultrasonographic measurements can be complementary for clinical RA disease activity measures with clinical efficiency, and technical guidelines were in need for clinical routine practice.
- Open Access
- 8 February 2017
- Published by Impact Journals, LLC in Oncotarget
- Vol. 8 (15) , 24828-24839
Autoantibodies against glucose-regulated protein 78 as serological biomarkers in metastatic and recurrent hepatocellular carcinoma
Autoantibodies against glucose-regulated protein 78 as serological biomarkers in metastatic and recurrent hepatocellular carcinoma
- 8 February 2017
- Published by Impact Journals, LLC in Oncotarget
- Vol. 8 (15) , 24828-24839
Open AccessAutoantibodies against glucose-regulated protein 78 as serological biomarkers in metastatic and recurrent hepatocellular carcinoma
Autoantibodies against glucose-regulated protein 78 as serological biomarkers in metastatic and recurrent hepatocellular carcinoma