Ashot S. Manvelyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ashot S. Manvelyan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Anzhela Stanislavovna Brago
Peoples' Friendship University of Russia
5 shared publications - Svetlanan Nicolaevna Razumova
Peoples’ Friendship University of Russia named after Patrice Lumumba
5 shared publications - Dmitrii Vitalevich Serebrov
Peoples’ Friendship University of Russia
2 shared publications - Kirill Dmitrievich Serebrov
Peoples’ Friendship University of Russia
2 shared publications - Z.T. Aymaletdinova
RUDN University
2 shared publications - Zoya Alekseevna Guryeva
RUDN University
2 shared publications
Latest Publications
- 4 July 2026
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 29 (2) , 23-27
Comparative characteristics of the enamel surface of permanent teeth during air-water polishing (a pilot study)
Nowadays, the use of air-water devices combined with abrasive components is one of the important steps in the prevention of caries and periodontal diseases. The success of this procedure largely depends on the composition of the abrasive powder, as well as on the size and shape of the particles. There is a need to find optimal components for air-water polishing that can effectively and safely remove both supragingival and subgingival plaque, as well as plaque around restorations and prosthetic constructions. Aim: comparative assessment of changes in surface roughness (Sa) of permanent tooth enamel after air-water polishing with particles of different sizes and shapes. Materials and methods. Enamel surface roughness was determined by profilometry on crown samples of 80 permanent teeth, randomly divided into 4 groups (n=20). All samples were subjected to air-water polishing with abrasive components according to the group. Group I used an erythritol-based powder — 14 µm Air flow Plus (EMS, Switzerland); Group II — sodium bicarbonate — 40 µm “Aero Profi Comfort” (Omega Dent, Russia); Group III — sodium bicarbonate (50–60 µm) and calcium carbonate (50–70 µm) “Flow-Cleans Profi” (TechnoDent, Russia); Group IV — glycine (25 µm) “Air-Cleans Perio” (VladMiVa, Russia). Scanning was performed before and after treatment in a selected field of study. Results. Data are presented as medians due to non-normal distribution. In Group I (Air flow Plus) the median increased from 152.5 to 164.5 nm; in Group II (Aero Profi Comfort) — from 163 to 173 nm; in Group III (FlowCleans Profi) — from 191.5 to 238.5 nm; in Group IV (AirCleans Perio) — decreased from 328.0 to 253.0 nm. No statistically significant differences were found (p>0.05). Conclusion. Erythritol granules with a small particle size of 14 µm showed a minimal tendency to increase the Sa roughness value, whereas the powder based on a combination of sodium bicarbonate (50–60 µm) and calcium carbonate (50–70 µm) contributed to the greatest increase. Glycine particles of 25 µm contributed to a decrease in roughness. Preliminary data do not allow final clinical recommendations to be made, but they provide a rationale for further research with a larger sample size to confirm or refute the observed trends.
- 4 July 2026
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 29 (2) , 23-27
Comparative characteristics of the enamel surface of permanent teeth during air-water polishing (a pilot study)
Nowadays, the use of air-water devices combined with abrasive components is one of the important steps in the prevention of caries and periodontal diseases. The success of this procedure largely depends on the composition of the abrasive powder, as well as on the size and shape of the particles. There is a need to find optimal components for air-water polishing that can effectively and safely remove both supragingival and subgingival plaque, as well as plaque around restorations and prosthetic constructions. Aim: comparative assessment of changes in surface roughness (Sa) of permanent tooth enamel after air-water polishing with particles of different sizes and shapes. Materials and methods. Enamel surface roughness was determined by profilometry on crown samples of 80 permanent teeth, randomly divided into 4 groups (n=20). All samples were subjected to air-water polishing with abrasive components according to the group. Group I used an erythritol-based powder — 14 µm Air flow Plus (EMS, Switzerland); Group II — sodium bicarbonate — 40 µm “Aero Profi Comfort” (Omega Dent, Russia); Group III — sodium bicarbonate (50–60 µm) and calcium carbonate (50–70 µm) “Flow-Cleans Profi” (TechnoDent, Russia); Group IV — glycine (25 µm) “Air-Cleans Perio” (VladMiVa, Russia). Scanning was performed before and after treatment in a selected field of study. Results. Data are presented as medians due to non-normal distribution. In Group I (Air flow Plus) the median increased from 152.5 to 164.5 nm; in Group II (Aero Profi Comfort) — from 163 to 173 nm; in Group III (FlowCleans Profi) — from 191.5 to 238.5 nm; in Group IV (AirCleans Perio) — decreased from 328.0 to 253.0 nm. No statistically significant differences were found (p>0.05). Conclusion. Erythritol granules with a small particle size of 14 µm showed a minimal tendency to increase the Sa roughness value, whereas the powder based on a combination of sodium bicarbonate (50–60 µm) and calcium carbonate (50–70 µm) contributed to the greatest increase. Glycine particles of 25 µm contributed to a decrease in roughness. Preliminary data do not allow final clinical recommendations to be made, but they provide a rationale for further research with a larger sample size to confirm or refute the observed trends.
- Open Access
- 14 November 2024
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 28 (4) , 383-391
Indices for complete dentures after cleaning at home
Background: According to experts, there are more than 350 million fully edentulous patients globally, accounting for 7% of the world population. Edentulous patients require dentures to maintain a good quality of life. Complete dentures need to be cleaned on a regular basis to prevent their microbial contamination and inflammatory complications. Aim: To assess the efficacy of Anolit ANK Super solution for cleaning complete dentures at home. Materials and Methods: The hygiene of complete dentures was assessed using the Ulitovsky–Leontiev index. The efficacy of cleaning complete dentures with Anolit ANK Super solution compared to 0.05% chlorhexidine bigluconate solution was assessed. Moreover, statistical analysis methods were used: normality test; threshold value, or baseline significance level p=0.05; intragroup comparison (6 comparisons) with the Bonferroni correction (critical p=0.0083). Results: When assessing the hygiene of dentures using the Ulitovsky–Leontiev index, the denture cleanliness index (DCI) changed from 4.65 points (poor denture hygiene) to 3.50 points (satisfactory denture hygiene) after one month of using Anolit ANK Super solution. After three months of using Anolit ANK Super solution, the DCI changed from 3.50 points (satisfactory denture hygiene) to 2.60 points (good denture hygiene). After six months of using Anolit ANK Super solution, the DCI changed from 2.60 points (good denture hygiene) to 1.55 points (very good denture hygiene). After one month of using 0.05% chlorhexidine bigluconate solution, the DCI changed from 4.85 points (poor denture hygiene) to 4.40 points (poor denture hygiene) (p=0.0083). After three months of using 0.05% chlorhexidine bigluconate solution, the DCI changed from 4.40 points (poor denture hygiene) to 3.50 points (satisfactory denture hygiene) (p=0.0083). After six months of using 0.05% chlorhexidine bigluconate solution, the DCI changed from 3.50 points (satisfactory denture hygiene) to 2.60 points (good denture hygiene) (p=0.0083). Conclusion: The follow-up revealed that, with similar duration of exposure to test solutions, Anolit ANK Super solution for cleaning dentures at home used for 6 months decreased the DCI threefold from baseline (p=0.000002) and improved denture hygiene from poor to good.
- 14 November 2024
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 28 (4) , 383-391
Open AccessIndices for complete dentures after cleaning at home
Background: According to experts, there are more than 350 million fully edentulous patients globally, accounting for 7% of the world population. Edentulous patients require dentures to maintain a good quality of life. Complete dentures need to be cleaned on a regular basis to prevent their microbial contamination and inflammatory complications. Aim: To assess the efficacy of Anolit ANK Super solution for cleaning complete dentures at home. Materials and Methods: The hygiene of complete dentures was assessed using the Ulitovsky–Leontiev index. The efficacy of cleaning complete dentures with Anolit ANK Super solution compared to 0.05% chlorhexidine bigluconate solution was assessed. Moreover, statistical analysis methods were used: normality test; threshold value, or baseline significance level p=0.05; intragroup comparison (6 comparisons) with the Bonferroni correction (critical p=0.0083). Results: When assessing the hygiene of dentures using the Ulitovsky–Leontiev index, the denture cleanliness index (DCI) changed from 4.65 points (poor denture hygiene) to 3.50 points (satisfactory denture hygiene) after one month of using Anolit ANK Super solution. After three months of using Anolit ANK Super solution, the DCI changed from 3.50 points (satisfactory denture hygiene) to 2.60 points (good denture hygiene). After six months of using Anolit ANK Super solution, the DCI changed from 2.60 points (good denture hygiene) to 1.55 points (very good denture hygiene). After one month of using 0.05% chlorhexidine bigluconate solution, the DCI changed from 4.85 points (poor denture hygiene) to 4.40 points (poor denture hygiene) (p=0.0083). After three months of using 0.05% chlorhexidine bigluconate solution, the DCI changed from 4.40 points (poor denture hygiene) to 3.50 points (satisfactory denture hygiene) (p=0.0083). After six months of using 0.05% chlorhexidine bigluconate solution, the DCI changed from 3.50 points (satisfactory denture hygiene) to 2.60 points (good denture hygiene) (p=0.0083). Conclusion: The follow-up revealed that, with similar duration of exposure to test solutions, Anolit ANK Super solution for cleaning dentures at home used for 6 months decreased the DCI threefold from baseline (p=0.000002) and improved denture hygiene from poor to good.
- 23 October 2023
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 27 (4) , 335-345
Methods of cleaning removable dentures
Most older patients use removable dentures, and the need for these dentures increases every year. Improving oral hygiene and denture hygiene is required in 42% to 76% of cases. Maintaining good oral hygiene is the prevention of various dental diseases and the long-term preservation of dental treatment results. The review aimed to examine the status of the issue on methods of disinfection of removable dentures (partial and complete) at home. A literature search was conducted on methods of disinfection of complete and partial removable dentures using Scopus, PubMed, Web of Science, eLibrary, and disserCat. Search criteria: review articles, scientific articles and patents (in Russian or English), published no earlier than 2013, by keywords: removable dentures, oral microbiota of patients with removable dentures, hygiene of removable dentures, denture stomatitis and methods of hygienic treatment of dentures. A total of 218 articles were studied. After a full-text analysis, 30 papers that met the search criteria were selected. The use of toothpaste for cleaning dentures has been studied in 17% of scientific studies (n=5). The use of special disinfectant solutions was investigated in 53% (n=16). Approximately 20% (n=6) of the literature reviewed methods for disinfecting dentures using special devices. Methods of covering dentures with protective varnish were described in 10% (n=3) of the articles. Existing methods for home denture care show a wide range of effectiveness, often with contradictory data. The selection of adequate methods of denture hygiene at home is an important issue that requires further study.
- 23 October 2023
- Published by ECO-Vector LLC in Russian Journal of Dentistry
- Vol. 27 (4) , 335-345
Methods of cleaning removable dentures
Most older patients use removable dentures, and the need for these dentures increases every year. Improving oral hygiene and denture hygiene is required in 42% to 76% of cases. Maintaining good oral hygiene is the prevention of various dental diseases and the long-term preservation of dental treatment results. The review aimed to examine the status of the issue on methods of disinfection of removable dentures (partial and complete) at home. A literature search was conducted on methods of disinfection of complete and partial removable dentures using Scopus, PubMed, Web of Science, eLibrary, and disserCat. Search criteria: review articles, scientific articles and patents (in Russian or English), published no earlier than 2013, by keywords: removable dentures, oral microbiota of patients with removable dentures, hygiene of removable dentures, denture stomatitis and methods of hygienic treatment of dentures. A total of 218 articles were studied. After a full-text analysis, 30 papers that met the search criteria were selected. The use of toothpaste for cleaning dentures has been studied in 17% of scientific studies (n=5). The use of special disinfectant solutions was investigated in 53% (n=16). Approximately 20% (n=6) of the literature reviewed methods for disinfecting dentures using special devices. Methods of covering dentures with protective varnish were described in 10% (n=3) of the articles. Existing methods for home denture care show a wide range of effectiveness, often with contradictory data. The selection of adequate methods of denture hygiene at home is an important issue that requires further study.
- Open Access
- 24 September 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (3) , 134-139
Evaluation of the size and shape of powder components for air polishing of the surface of hard tooth tissue
Применение метода водно-воздушной полировки при профессиональной гигиене полости рта обеспечивает эффективное удаление биопленки со всех поверхностей зуба. В настоящее время разработано несколько абразивных порошков из гидрокарбоната натрия, карбоната кальция, глицина или эритритола. В зависимости от размера и формы гранул воздействие этих компонентов на поверхность твердых тканей зуба способно как увеличить, так и уменьшить шероховатость. Цель — профилометрическое изучение размера и формы гранул абразивов для профессиональной гигиены полости рта. Для исследования было выбрано 5 образцов абразивных порошков: 1) «Аэр профи комфорт» (Омега-дент, Россия) из гидрокарбоната натрия (40 мкм); 2) «Флоу-Клинз Профи» (ТехноДент, Россия) из гидрокарбоната натрия (50—60 мкм) и карбоната кальция (50—70 мкм); 3) «Аэр-Клинз Перио» (ВладМиВа, Россия) из глицина (25 мкм); 4) Airflow Plus (EMS, Швейцария) из эритритола (14 мкм); 5) Rhapsody Flow (Queen Dental, Германия) из гидрокарбоната натрия (40 мкм). Проведено сканирование и определение среднего размера частиц, а также формы отдельно взятых гранул на оптическом 3D-профилометре. В образцах 1—4 форма частиц соответствует заявленной производителем. Средний размер гранул абразива в нескольких образцах превышал значения, указанные в инструкции: образец № 1 — 71,4 мкм, № 4 — 41,7 мкм, № 5 — 79,4 мкм. Указанные производителями средние размеры частиц абразивных порошков не всегда подтверждаются данными профилометрии. Water-air polishing is an effective method for removing biofilm from all tooth surfaces in professional oral hygiene. A variety of abrasive powders have been developed for this purpose. These powders are based on sodium bicarbonate, calcium carbonate, glycine or erythritol. Depending on the granule size and shape, these powders can increase or decrease dental hard tissue surface roughness. Objective — profilometric study of the size and shape of granules of professional oral hygiene abrasives. . For the study, five samples of abrasive powders were selected: 1) Air Profi Comfort (Omega-Dent, Russia) made of sodium bicarbonate (40 μm); 2) Flow-Cleans Pro (TechnoDent, Russia) made of sodium bicarbonate (50—60 μm) and calcium carbonate (50—70 μm); 3) Air-Cleans Perio (VladMiVa, Russia) made of glycine (25 microns); 4) Airflow Plus (EMS, Switzerland) made of erythritol (14 μm); 5) Rhapsody Flow (Queen Dental, Germany) made of sodium bicarbonate (40 μm). Scanning and determination of the average particle size as well as the shape of individual granules on an optical 3D profilometer were performed. . In samples 1—4 the shape of particles corresponds to the manufacturer’s statement. The average size of abrasive granules in several samples exceeded the values specified in the instructions: sample 1 — 71.4 μm, sample 4 — 41.7 μm, sample 5 — 79.4 μm. . Based on profilometry data, it appears that manufacturers’ specified average particle sizes of abrasive powders are not always accurate.
- 24 September 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (3) , 134-139
Open AccessEvaluation of the size and shape of powder components for air polishing of the surface of hard tooth tissue
Применение метода водно-воздушной полировки при профессиональной гигиене полости рта обеспечивает эффективное удаление биопленки со всех поверхностей зуба. В настоящее время разработано несколько абразивных порошков из гидрокарбоната натрия, карбоната кальция, глицина или эритритола. В зависимости от размера и формы гранул воздействие этих компонентов на поверхность твердых тканей зуба способно как увеличить, так и уменьшить шероховатость. Цель — профилометрическое изучение размера и формы гранул абразивов для профессиональной гигиены полости рта. Для исследования было выбрано 5 образцов абразивных порошков: 1) «Аэр профи комфорт» (Омега-дент, Россия) из гидрокарбоната натрия (40 мкм); 2) «Флоу-Клинз Профи» (ТехноДент, Россия) из гидрокарбоната натрия (50—60 мкм) и карбоната кальция (50—70 мкм); 3) «Аэр-Клинз Перио» (ВладМиВа, Россия) из глицина (25 мкм); 4) Airflow Plus (EMS, Швейцария) из эритритола (14 мкм); 5) Rhapsody Flow (Queen Dental, Германия) из гидрокарбоната натрия (40 мкм). Проведено сканирование и определение среднего размера частиц, а также формы отдельно взятых гранул на оптическом 3D-профилометре. В образцах 1—4 форма частиц соответствует заявленной производителем. Средний размер гранул абразива в нескольких образцах превышал значения, указанные в инструкции: образец № 1 — 71,4 мкм, № 4 — 41,7 мкм, № 5 — 79,4 мкм. Указанные производителями средние размеры частиц абразивных порошков не всегда подтверждаются данными профилометрии. Water-air polishing is an effective method for removing biofilm from all tooth surfaces in professional oral hygiene. A variety of abrasive powders have been developed for this purpose. These powders are based on sodium bicarbonate, calcium carbonate, glycine or erythritol. Depending on the granule size and shape, these powders can increase or decrease dental hard tissue surface roughness. Objective — profilometric study of the size and shape of granules of professional oral hygiene abrasives. . For the study, five samples of abrasive powders were selected: 1) Air Profi Comfort (Omega-Dent, Russia) made of sodium bicarbonate (40 μm); 2) Flow-Cleans Pro (TechnoDent, Russia) made of sodium bicarbonate (50—60 μm) and calcium carbonate (50—70 μm); 3) Air-Cleans Perio (VladMiVa, Russia) made of glycine (25 microns); 4) Airflow Plus (EMS, Switzerland) made of erythritol (14 μm); 5) Rhapsody Flow (Queen Dental, Germany) made of sodium bicarbonate (40 μm). Scanning and determination of the average particle size as well as the shape of individual granules on an optical 3D profilometer were performed. . In samples 1—4 the shape of particles corresponds to the manufacturer’s statement. The average size of abrasive granules in several samples exceeded the values specified in the instructions: sample 1 — 71.4 μm, sample 4 — 41.7 μm, sample 5 — 79.4 μm. . Based on profilometry data, it appears that manufacturers’ specified average particle sizes of abrasive powders are not always accurate.
- Open Access
- 13 January 2023
- Published by Alfmed LLC in Medical alphabet
- No. 34,p. 14-18
Evaluation of the Roughness of the Enamel Surface According to Profilometry Data (Pilot Study)
The right choice of home hygiene products: toothbrush and toothpaste are an important aspect. The combination of different hardness of toothbrush and varying abrasiveness of tooth paste has not been fully explored.Aim. To study the effect of a soft brush on the enamel surface according to profilometry data.Materials and methods. For research, a special device was used to simulate the annual brushing of teeth. Abrasion was carried out on 6 extracted teeth, according to periodontal indications. Samples size was 1x1cm from 6 teeth removed for periodontal indications. Abrasion was carried out with a soft brush without the addition of paste on samples № 1,2,3 and with a soft brush in combination with a low abrasive paste with RDA 35 on samples № 4,5,6. The results of profilometry data were recorded at following time points - the initial state of the tooth, 1 week, 1 month, 6 months, 1 year.Conclusion. Using only a soft brush without toothpaste does not change the roughness of the tooth surface while simulating an annual brushing and the combination of a soft brush with a low abrasive paste polishes the enamel surface.
- 13 January 2023
- Published by Alfmed LLC in Medical alphabet
- No. 34,p. 14-18
Open AccessEvaluation of the Roughness of the Enamel Surface According to Profilometry Data (Pilot Study)
The right choice of home hygiene products: toothbrush and toothpaste are an important aspect. The combination of different hardness of toothbrush and varying abrasiveness of tooth paste has not been fully explored.Aim. To study the effect of a soft brush on the enamel surface according to profilometry data.Materials and methods. For research, a special device was used to simulate the annual brushing of teeth. Abrasion was carried out on 6 extracted teeth, according to periodontal indications. Samples size was 1x1cm from 6 teeth removed for periodontal indications. Abrasion was carried out with a soft brush without the addition of paste on samples № 1,2,3 and with a soft brush in combination with a low abrasive paste with RDA 35 on samples № 4,5,6. The results of profilometry data were recorded at following time points - the initial state of the tooth, 1 week, 1 month, 6 months, 1 year.Conclusion. Using only a soft brush without toothpaste does not change the roughness of the tooth surface while simulating an annual brushing and the combination of a soft brush with a low abrasive paste polishes the enamel surface.