Robert Henning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Robert Henning has a total of 121 co-authors. Here are the top co-authors by number of shared publications:
- In-Sik Kim
Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, USA
3 shared publications - Vukica Šrajer
BioCARS, Center for Advanced Radiation Sources, The University of Chicago
3 shared publications - Doeke Romke Hekstra
Department of Molecular and Cellular Biology, Harvard University, Cambridge, MA 02138, USA
2 shared publications - Hyotcherl Ihee
Center for Advanced Reaction Dynamics, Institute for Basic Science (IBS), Daejeon, Republic of Korea
2 shared publications Irina Kosheleva
Center for Advanced Radiation Sources, The University of Chicago, Chicago, Illinois, 60637, USA
2 shared publications- Irina Kosheleva
Center for Advanced Radiation Sources, The University of Chicago 2 , Chicago, Illinois 60637, USA
2 shared publications
Latest Publications
- Open Access
- 11 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 562-579
Absolute scaling of small- and wide-angle X-ray scattering images recorded with short duration X-ray pulses on a large area fiber-taper X-ray detector
We have developed an X-ray scattering setup capable of capturing time-resolved small-angle X-ray scattering (SAXS) and wide-angle X-ray scattering (WAXS) images spanning q = 0.02 to over 5.2 Å −1 on a single, large area Rayonix MX340-HS detector with time resolution as short as 120 ps. A key feature of this setup is a 0.51 mm-diameter partially transmissive beamstop that enables non-invasive, image-by-image recording of direct beam position and intensity during acquisition. This beamstop attenuates 12 keV undulator radiation by approximately eight orders of magnitude while suppressing off-axis second harmonic radiation. Continuous monitoring of the direct beam position facilitates long-term beam alignment and allows datasets acquired at different times to be placed on a common absolute scale prior to differencing. The accuracy of the difference scattering curves is ultimately limited by the performance of the large area, fiber-taper X-ray detector used in this study. To address accuracy issues, we present a detailed statistical characterization of the detector readout noise and responsivity and introduce a variance-per-count statistic that enables identification of zinger-free averages, generation of precise uniformity corrections, and statistically weighted conversion of two-dimensional scattering images into near shot-noise-limited one-dimensional scattering curves. The detector point-spread function and its effects on resolution and scaling are examined using scattering data from a fused silica plate and from apoferritin solution in a capillary. The ability to acquire high accuracy, high precision scattering curves over a broad range of q and temperatures provides a robust foundation for time-resolved studies of biomolecular structure and dynamics in solution.
- 11 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 33 (3) , 562-579
Open AccessAbsolute scaling of small- and wide-angle X-ray scattering images recorded with short duration X-ray pulses on a large area fiber-taper X-ray detector
We have developed an X-ray scattering setup capable of capturing time-resolved small-angle X-ray scattering (SAXS) and wide-angle X-ray scattering (WAXS) images spanning q = 0.02 to over 5.2 Å −1 on a single, large area Rayonix MX340-HS detector with time resolution as short as 120 ps. A key feature of this setup is a 0.51 mm-diameter partially transmissive beamstop that enables non-invasive, image-by-image recording of direct beam position and intensity during acquisition. This beamstop attenuates 12 keV undulator radiation by approximately eight orders of magnitude while suppressing off-axis second harmonic radiation. Continuous monitoring of the direct beam position facilitates long-term beam alignment and allows datasets acquired at different times to be placed on a common absolute scale prior to differencing. The accuracy of the difference scattering curves is ultimately limited by the performance of the large area, fiber-taper X-ray detector used in this study. To address accuracy issues, we present a detailed statistical characterization of the detector readout noise and responsivity and introduce a variance-per-count statistic that enables identification of zinger-free averages, generation of precise uniformity corrections, and statistically weighted conversion of two-dimensional scattering images into near shot-noise-limited one-dimensional scattering curves. The detector point-spread function and its effects on resolution and scaling are examined using scattering data from a fused silica plate and from apoferritin solution in a capillary. The ability to acquire high accuracy, high precision scattering curves over a broad range of q and temperatures provides a robust foundation for time-resolved studies of biomolecular structure and dynamics in solution.
- Open Access
- 28 January 2026
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 302 (3) , 111215
Time-resolved Mn Kα emission reveals early redox dynamics in the S3 to S0 transition of the photosystem II Kok cycle
- 28 January 2026
- Published by Elsevier in Journal of Biological Chemistry
- Vol. 302 (3) , 111215
Open AccessTime-resolved Mn Kα emission reveals early redox dynamics in the S3 to S0 transition of the photosystem II Kok cycle
- Open Access
- 1 November 2024
- Published by AIP Publishing in Structural Dynamics
- Vol. 11 (6) , 064301
Scaling and merging time-resolved pink-beam diffraction with variational inference
Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.
- 1 November 2024
- Published by AIP Publishing in Structural Dynamics
- Vol. 11 (6) , 064301
Open AccessScaling and merging time-resolved pink-beam diffraction with variational inference
Time-resolved x-ray crystallography (TR-X) at synchrotrons and free electron lasers is a promising technique for recording dynamics of molecules at atomic resolution. While experimental methods for TR-X have proliferated and matured, data analysis is often difficult. Extracting small, time-dependent changes in signal is frequently a bottleneck for practitioners. Recent work demonstrated this challenge can be addressed when merging redundant observations by a statistical technique known as variational inference (VI). However, the variational approach to time-resolved data analysis requires identification of successful hyperparameters in order to optimally extract signal. In this case study, we present a successful application of VI to time-resolved changes in an enzyme, DJ-1, upon mixing with a substrate molecule, methylglyoxal. We present a strategy to extract high signal-to-noise changes in electron density from these data. Furthermore, we conduct an ablation study, in which we systematically remove one hyperparameter at a time to demonstrate the impact of each hyperparameter choice on the success of our model. We expect this case study will serve as a practical example for how others may deploy VI in order to analyze their time-resolved diffraction data.
- Open Access
- 26 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Serial X-ray liquidography: multi-dimensional assay framework for exploring biomolecular structural dynamics with microgram quantities
Understanding protein structure and kinetics under physiological conditions is crucial for elucidating complex biological processes. While time-resolved (TR) techniques have advanced to track molecular actions, their practical application in biological reactions is often confined to reversible photoreactions within limited experimental parameters due to inefficient sample utilization and inflexibility of experimental setups. Here, we introduce serial X-ray liquidography (SXL), a technique that combines time-resolved X-ray liquidography with a fixed target of serially arranged microchambers. SXL breaks through the previously mentioned barriers, enabling microgram-scale TR studies of both irreversible and reversible reactions of even a non-photoactive protein. We demonstrate its versatility in studying a wide range of biological reactions, highlighting its potential as a flexible and multi-dimensional assay framework for kinetic and structural characterization. Leveraging X-ray free-electron lasers and micro-focused X-ray pulses promises further enhancements in both temporal resolution and minimizing sample quantity. SXL offers unprecedented insights into the structural and kinetic landscapes of molecular actions, paving the way for a deeper understanding of complex biological processes.
- 26 July 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-13
Open AccessSerial X-ray liquidography: multi-dimensional assay framework for exploring biomolecular structural dynamics with microgram quantities
Understanding protein structure and kinetics under physiological conditions is crucial for elucidating complex biological processes. While time-resolved (TR) techniques have advanced to track molecular actions, their practical application in biological reactions is often confined to reversible photoreactions within limited experimental parameters due to inefficient sample utilization and inflexibility of experimental setups. Here, we introduce serial X-ray liquidography (SXL), a technique that combines time-resolved X-ray liquidography with a fixed target of serially arranged microchambers. SXL breaks through the previously mentioned barriers, enabling microgram-scale TR studies of both irreversible and reversible reactions of even a non-photoactive protein. We demonstrate its versatility in studying a wide range of biological reactions, highlighting its potential as a flexible and multi-dimensional assay framework for kinetic and structural characterization. Leveraging X-ray free-electron lasers and micro-focused X-ray pulses promises further enhancements in both temporal resolution and minimizing sample quantity. SXL offers unprecedented insights into the structural and kinetic landscapes of molecular actions, paving the way for a deeper understanding of complex biological processes.
- 15 July 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 161 (3)
Unlocking the unfolded structure of ubiquitin: Combining time-resolved x-ray solution scattering and molecular dynamics to generate unfolded ensembles
The unfolding dynamics of ubiquitin were studied using a combination of x-ray solution scattering (XSS) and molecular dynamics (MD) simulations. The kinetic analysis of the XSS ubiquitin signals showed that the protein unfolds through a two-state process, independent of the presence of destabilizing salts. In order to characterize the ensemble of unfolded states in atomic detail, the experimental XSS results were used as a constraint in the MD simulations through the incorporation of x-ray scattering derived potential to drive the folded ubiquitin structure toward sampling unfolded states consistent with the XSS signals. We detail how biased MD simulations provide insight into unfolded states that are otherwise difficult to resolve and underscore how experimental XSS data can be combined with MD to efficiently sample structures away from the native state. Our results indicate that ubiquitin samples unfolded in states with a high degree of loss in secondary structure yet without a collapse to a molten globule or fully solvated extended chain. Finally, we propose how using biased-MD can significantly decrease the computational time and resources required to sample experimentally relevant nonequilibrium states.
- 15 July 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 161 (3)
Unlocking the unfolded structure of ubiquitin: Combining time-resolved x-ray solution scattering and molecular dynamics to generate unfolded ensembles
The unfolding dynamics of ubiquitin were studied using a combination of x-ray solution scattering (XSS) and molecular dynamics (MD) simulations. The kinetic analysis of the XSS ubiquitin signals showed that the protein unfolds through a two-state process, independent of the presence of destabilizing salts. In order to characterize the ensemble of unfolded states in atomic detail, the experimental XSS results were used as a constraint in the MD simulations through the incorporation of x-ray scattering derived potential to drive the folded ubiquitin structure toward sampling unfolded states consistent with the XSS signals. We detail how biased MD simulations provide insight into unfolded states that are otherwise difficult to resolve and underscore how experimental XSS data can be combined with MD to efficiently sample structures away from the native state. Our results indicate that ubiquitin samples unfolded in states with a high degree of loss in secondary structure yet without a collapse to a molten globule or fully solvated extended chain. Finally, we propose how using biased-MD can significantly decrease the computational time and resources required to sample experimentally relevant nonequilibrium states.
- Open Access
- 22 February 2024
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 121 (9)
Perturbative diffraction methods resolve a conformational switch that facilitates a two-step enzymatic mechanism
Enzymes catalyze biochemical reactions through precise positioning of substrates, cofactors, and amino acids to modulate the transition-state free energy. However, the role of conformational dynamics remains poorly understood due to poor experimental access. This shortcoming is evident with Escherichia coli dihydrofolate reductase (DHFR), a model system for the role of protein dynamics in catalysis, for which it is unknown how the enzyme regulates the different active site environments required to facilitate proton and hydride transfer. Here, we describe ligand-, temperature-, and electric-field-based perturbations during X-ray diffraction experiments to map the conformational dynamics of the Michaelis complex of DHFR. We resolve coupled global and local motions and find that these motions are engaged by the protonated substrate to promote efficient catalysis. This result suggests a fundamental design principle for multistep enzymes in which pre-existing dynamics enable intermediates to drive rapid electrostatic reorganization to facilitate subsequent chemical steps.
- 22 February 2024
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 121 (9)
Open AccessPerturbative diffraction methods resolve a conformational switch that facilitates a two-step enzymatic mechanism
Enzymes catalyze biochemical reactions through precise positioning of substrates, cofactors, and amino acids to modulate the transition-state free energy. However, the role of conformational dynamics remains poorly understood due to poor experimental access. This shortcoming is evident with Escherichia coli dihydrofolate reductase (DHFR), a model system for the role of protein dynamics in catalysis, for which it is unknown how the enzyme regulates the different active site environments required to facilitate proton and hydride transfer. Here, we describe ligand-, temperature-, and electric-field-based perturbations during X-ray diffraction experiments to map the conformational dynamics of the Michaelis complex of DHFR. We resolve coupled global and local motions and find that these motions are engaged by the protonated substrate to promote efficient catalysis. This result suggests a fundamental design principle for multistep enzymes in which pre-existing dynamics enable intermediates to drive rapid electrostatic reorganization to facilitate subsequent chemical steps.
- Open Access
- 1 January 2024
- Published by AIP Publishing in Structural Dynamics
- Vol. 11 (1) , 014301
BioCARS: Synchrotron facility for probing structural dynamics of biological macromolecules
A major goal in biomedical science is to move beyond static images of proteins and other biological macromolecules to the internal dynamics underlying their function. This level of study is necessary to understand how these molecules work and to engineer new functions and modulators of function. Stemming from a visionary commitment to this problem by Keith Moffat decades ago, a community of structural biologists has now enabled a set of x-ray scattering technologies for observing intramolecular dynamics in biological macromolecules at atomic resolution and over the broad range of timescales over which motions are functionally relevant. Many of these techniques are provided by BioCARS, a cutting-edge synchrotron radiation facility built under Moffat leadership and located at the Advanced Photon Source at Argonne National Laboratory. BioCARS enables experimental studies of molecular dynamics with time resolutions spanning from 100 ps to seconds and provides both time-resolved x-ray crystallography and small- and wide-angle x-ray scattering. Structural changes can be initiated by several methods—UV/Vis pumping with tunable picosecond and nanosecond laser pulses, substrate diffusion, and global perturbations, such as electric field and temperature jumps. Studies of dynamics typically involve subtle perturbations to molecular structures, requiring specialized computational techniques for data processing and interpretation. In this review, we present the challenges in experimental macromolecular dynamics and describe the current state of experimental capabilities at this facility. As Moffat imagined years ago, BioCARS is now positioned to catalyze the scientific community to make fundamental advances in understanding proteins and other complex biological macromolecules.
- 1 January 2024
- Published by AIP Publishing in Structural Dynamics
- Vol. 11 (1) , 014301
Open AccessBioCARS: Synchrotron facility for probing structural dynamics of biological macromolecules
A major goal in biomedical science is to move beyond static images of proteins and other biological macromolecules to the internal dynamics underlying their function. This level of study is necessary to understand how these molecules work and to engineer new functions and modulators of function. Stemming from a visionary commitment to this problem by Keith Moffat decades ago, a community of structural biologists has now enabled a set of x-ray scattering technologies for observing intramolecular dynamics in biological macromolecules at atomic resolution and over the broad range of timescales over which motions are functionally relevant. Many of these techniques are provided by BioCARS, a cutting-edge synchrotron radiation facility built under Moffat leadership and located at the Advanced Photon Source at Argonne National Laboratory. BioCARS enables experimental studies of molecular dynamics with time resolutions spanning from 100 ps to seconds and provides both time-resolved x-ray crystallography and small- and wide-angle x-ray scattering. Structural changes can be initiated by several methods—UV/Vis pumping with tunable picosecond and nanosecond laser pulses, substrate diffusion, and global perturbations, such as electric field and temperature jumps. Studies of dynamics typically involve subtle perturbations to molecular structures, requiring specialized computational techniques for data processing and interpretation. In this review, we present the challenges in experimental macromolecular dynamics and describe the current state of experimental capabilities at this facility. As Moffat imagined years ago, BioCARS is now positioned to catalyze the scientific community to make fundamental advances in understanding proteins and other complex biological macromolecules.
- Open Access
- 6 February 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 158 (5) , 054304
Axial vs equatorial: Capturing the intramolecular charge transfer state geometry in conformational polymorphic crystals of a donor–bridge–acceptor dyad in nanosecond-time-scale
Two conformational polymorphs of a donor–bridge–acceptor (D-B-A) dyad, p-(CH3)2N-C6H4-(CH2)2-(1-pyrenyl)/PyCHDMA, were studied, where the electron donor (D) moiety p-(CH3)2N-C6H4/DMA is connected through a bridging group (B), –CH2–CH2–, to the electron acceptor (A) moiety pyrene. Though molecular dyads like PyCHDMA have the potential to change solar energy into electrical current through the process of photoinduced intramolecular charge transfer (ICT), the major challenge is the real-time investigation of the photoinduced ICT process in crystals, necessary to design solid-state optoelectronic materials. The time-correlated single photon counting (TCSPC) measurements with the single crystals showed that the ICT state lifetime of the thermodynamic form, PyCHDMA1 (pyrene and DMA: axial), is ∼3 ns, whereas, for the kinetic form, PyCHDMA20 (pyrene and DMA: equatorial), it is ∼7 ns, while photoexcited with 375 nm radiation. The polymorphic crystals were photo-excited and subsequently probed with a pink Laue x-ray beam in time-resolved x-ray diffraction (TRXRD) measurements. The TRXRD results suggest that in the ICT state, due to electron transfer from the tertiary N-atom in DMA moiety to the bridging group and pyrene moiety, a decreased repulsion between the lone-pair and the bond-pair at N-atom induces planarity in the C–N–(CH3)2 moiety, in both polymorphs. The Natural Bond Orbital calculations and partial atomic charge analysis by Hirshfeld partitioning also corroborated the same. Although the interfragment charge transfer (IFCT) analysis using the TDDFT results showed that for the charge transfer excitation in both conformers, the electrons were transferred from the DMA moiety to mostly the pyrene moiety, the bridging group has little role to play in that.
- 6 February 2023
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 158 (5) , 054304
Open AccessAxial vs equatorial: Capturing the intramolecular charge transfer state geometry in conformational polymorphic crystals of a donor–bridge–acceptor dyad in nanosecond-time-scale
Two conformational polymorphs of a donor–bridge–acceptor (D-B-A) dyad, p-(CH3)2N-C6H4-(CH2)2-(1-pyrenyl)/PyCHDMA, were studied, where the electron donor (D) moiety p-(CH3)2N-C6H4/DMA is connected through a bridging group (B), –CH2–CH2–, to the electron acceptor (A) moiety pyrene. Though molecular dyads like PyCHDMA have the potential to change solar energy into electrical current through the process of photoinduced intramolecular charge transfer (ICT), the major challenge is the real-time investigation of the photoinduced ICT process in crystals, necessary to design solid-state optoelectronic materials. The time-correlated single photon counting (TCSPC) measurements with the single crystals showed that the ICT state lifetime of the thermodynamic form, PyCHDMA1 (pyrene and DMA: axial), is ∼3 ns, whereas, for the kinetic form, PyCHDMA20 (pyrene and DMA: equatorial), it is ∼7 ns, while photoexcited with 375 nm radiation. The polymorphic crystals were photo-excited and subsequently probed with a pink Laue x-ray beam in time-resolved x-ray diffraction (TRXRD) measurements. The TRXRD results suggest that in the ICT state, due to electron transfer from the tertiary N-atom in DMA moiety to the bridging group and pyrene moiety, a decreased repulsion between the lone-pair and the bond-pair at N-atom induces planarity in the C–N–(CH3)2 moiety, in both polymorphs. The Natural Bond Orbital calculations and partial atomic charge analysis by Hirshfeld partitioning also corroborated the same. Although the interfragment charge transfer (IFCT) analysis using the TDDFT results showed that for the charge transfer excitation in both conformers, the electrons were transferred from the DMA moiety to mostly the pyrene moiety, the bridging group has little role to play in that.
- Open Access
- 1 February 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (2) , 490-499
Sample-minimizing co-flow cell for time-resolved pump–probe X-ray solution scattering
A fundamental problem in biological sciences is understanding how macromolecular machines work and how the structural changes of a molecule are connected to its function. Time-resolved techniques are vital in this regard and essential for understanding the structural dynamics of biomolecules. Time-resolved small- and wide-angle X-ray solution scattering has the capability to provide a multitude of information about the kinetics and global structural changes of molecules under their physiological conditions. However, standard protocols for such time-resolved measurements often require significant amounts of sample, which frequently render time-resolved measurements impossible. A cytometry-type sheath co-flow cell, developed at the BioCARS 14-ID beamline at the Advanced Photon Source, USA, allows time-resolved pump–probe X-ray solution scattering measurements to be conducted with sample consumption reduced by more than ten times compared with standard sample cells and protocols. The comparative capabilities of the standard and co-flow experimental setups were demonstrated by studying time-resolved signals in photoactive yellow protein.
- 1 February 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (2) , 490-499
Open AccessSample-minimizing co-flow cell for time-resolved pump–probe X-ray solution scattering
A fundamental problem in biological sciences is understanding how macromolecular machines work and how the structural changes of a molecule are connected to its function. Time-resolved techniques are vital in this regard and essential for understanding the structural dynamics of biomolecules. Time-resolved small- and wide-angle X-ray solution scattering has the capability to provide a multitude of information about the kinetics and global structural changes of molecules under their physiological conditions. However, standard protocols for such time-resolved measurements often require significant amounts of sample, which frequently render time-resolved measurements impossible. A cytometry-type sheath co-flow cell, developed at the BioCARS 14-ID beamline at the Advanced Photon Source, USA, allows time-resolved pump–probe X-ray solution scattering measurements to be conducted with sample consumption reduced by more than ten times compared with standard sample cells and protocols. The comparative capabilities of the standard and co-flow experimental setups were demonstrated by studying time-resolved signals in photoactive yellow protein.
- Open Access
- 25 July 2022
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 9 (5) , 610-624
Complementarity of neutron, XFEL and synchrotron crystallography for defining the structures of metalloenzymes at room temperature
Room-temperature macromolecular crystallography allows protein structures to be determined under close-to-physiological conditions, permits dynamic freedom in protein motions and enables time-resolved studies. In the case of metalloenzymes that are highly sensitive to radiation damage, such room-temperature experiments can present challenges, including increased rates of X-ray reduction of metal centres and site-specific radiation-damage artefacts, as well as in devising appropriate sample-delivery and data-collection methods. It can also be problematic to compare structures measured using different crystal sizes and light sources. In this study, structures of a multifunctional globin, dehaloperoxidase B (DHP-B), obtained using several methods of room-temperature crystallographic structure determination are described and compared. Here, data were measured from large single crystals and multiple microcrystals using neutrons, X-ray free-electron laser pulses, monochromatic synchrotron radiation and polychromatic (Laue) radiation light sources. These approaches span a range of 18 orders of magnitude in measurement time per diffraction pattern and four orders of magnitude in crystal volume. The first room-temperature neutron structures of DHP-B are also presented, allowing the explicit identification of the hydrogen positions. The neutron data proved to be complementary to the serial femtosecond crystallography data, with both methods providing structures free of the effects of X-ray radiation damage when compared with standard cryo-crystallography. Comparison of these room-temperature methods demonstrated the large differences in sample requirements, data-collection time and the potential for radiation damage between them. With regard to the structure and function of DHP-B, despite the results being partly limited by differences in the underlying structures, new information was gained on the protonation states of active-site residues which may guide future studies of DHP-B.
- 25 July 2022
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 9 (5) , 610-624
Open AccessComplementarity of neutron, XFEL and synchrotron crystallography for defining the structures of metalloenzymes at room temperature
Room-temperature macromolecular crystallography allows protein structures to be determined under close-to-physiological conditions, permits dynamic freedom in protein motions and enables time-resolved studies. In the case of metalloenzymes that are highly sensitive to radiation damage, such room-temperature experiments can present challenges, including increased rates of X-ray reduction of metal centres and site-specific radiation-damage artefacts, as well as in devising appropriate sample-delivery and data-collection methods. It can also be problematic to compare structures measured using different crystal sizes and light sources. In this study, structures of a multifunctional globin, dehaloperoxidase B (DHP-B), obtained using several methods of room-temperature crystallographic structure determination are described and compared. Here, data were measured from large single crystals and multiple microcrystals using neutrons, X-ray free-electron laser pulses, monochromatic synchrotron radiation and polychromatic (Laue) radiation light sources. These approaches span a range of 18 orders of magnitude in measurement time per diffraction pattern and four orders of magnitude in crystal volume. The first room-temperature neutron structures of DHP-B are also presented, allowing the explicit identification of the hydrogen positions. The neutron data proved to be complementary to the serial femtosecond crystallography data, with both methods providing structures free of the effects of X-ray radiation damage when compared with standard cryo-crystallography. Comparison of these room-temperature methods demonstrated the large differences in sample requirements, data-collection time and the potential for radiation damage between them. With regard to the structure and function of DHP-B, despite the results being partly limited by differences in the underlying structures, new information was gained on the protonation states of active-site residues which may guide future studies of DHP-B.