Ioannis Papathanasiou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ioannis Papathanasiou has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Spiros Zinelis
Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
6 shared publications George Papavasiliou
4 shared publicationsPhophi Kamposiora
4 shared publications- Aikaterini Petropoulou
Department of Fixed Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon Str., 11527 Athens, Greece
3 shared publications - George Eliades
Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, Greece
3 shared publications - Maria Dimitriadi
Department of Biomaterials, School of Dentistry, National and Kapodistrian University of Athens, 11527 Athens, Greece
3 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Digital implant transfer with coded healing abutments: A site-by-scanner accuracy study
- 27 October 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 177
Open AccessDigital implant transfer with coded healing abutments: A site-by-scanner accuracy study
- Open Access
- 15 April 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (4) , 191
Correction: Petropoulou et al. Conversion and Tack-Curing of Light-Cured Veneer Luting Agents. J. Funct. Biomater. 2025, 16, 307
- 15 April 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (4) , 191
Open AccessCorrection: Petropoulou et al. Conversion and Tack-Curing of Light-Cured Veneer Luting Agents. J. Funct. Biomater. 2025, 16, 307
- 10 October 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 163, 106173
Accuracy of single implant scans with an intermediate abutment-healing cap system. An in vitro study
- 10 October 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 163, 106173
Accuracy of single implant scans with an intermediate abutment-healing cap system. An in vitro study
- Open Access
- 26 August 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (9) , 307
Conversion and Tack-Curing of Light-Cured Veneer Luting Agents
Light attenuation and excess handling of light-cured luting agents create problems in bonding veneer restorations. The aim of the present study was to assess the curing capacity of light-cured veneer luting agents (VLA) [Choice 2 (CH2), G-Cem Veneer (GCV), Panavia LC Veneer (PNV), PermaCem LC Veneer (PMS), and Variolink Esthetic LC (VEV)] under lithium disilicate veneers, in the presence or absence of touch-cure primers (Adhese Universal Bond DC for VEV, G Premio Bond + DCA Activator for GCV, and V5 Tooth Primer V5 for PNV) and to evaluate material setting under two tack-curing irradiation modes (contact, distant). The methods used were ATR–FTIR spectroscopy and Vickers hardness (VHN) tests (n = 5/product and test). According to the results, all materials cured under the ceramic demonstrated significantly lower DC% from the controls, with a ranking of VEV, CH2 > GCV, PMS, PNV. The primers improved DC% by 4–13% only in the veneer groups. Tack-curing in contact mode demonstrated conversion and hardness values ranging from 37% to 78% and 31% to 57% of the controls respectively, corresponding to a vitreous state. For the distant mode, very low conversion values were found (0–7% of the controls), with untraceable indentations. It can be concluded that low translucency veneers reduce conversion of VLAs, which can be improved by using touch-cure activators. Tack-curing, as instructed, creates vitrified materials, resulting in difficult removal of set excess, which implies the need for better standardization of the procedure.
- 26 August 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (9) , 307
Open AccessConversion and Tack-Curing of Light-Cured Veneer Luting Agents
Light attenuation and excess handling of light-cured luting agents create problems in bonding veneer restorations. The aim of the present study was to assess the curing capacity of light-cured veneer luting agents (VLA) [Choice 2 (CH2), G-Cem Veneer (GCV), Panavia LC Veneer (PNV), PermaCem LC Veneer (PMS), and Variolink Esthetic LC (VEV)] under lithium disilicate veneers, in the presence or absence of touch-cure primers (Adhese Universal Bond DC for VEV, G Premio Bond + DCA Activator for GCV, and V5 Tooth Primer V5 for PNV) and to evaluate material setting under two tack-curing irradiation modes (contact, distant). The methods used were ATR–FTIR spectroscopy and Vickers hardness (VHN) tests (n = 5/product and test). According to the results, all materials cured under the ceramic demonstrated significantly lower DC% from the controls, with a ranking of VEV, CH2 > GCV, PMS, PNV. The primers improved DC% by 4–13% only in the veneer groups. Tack-curing in contact mode demonstrated conversion and hardness values ranging from 37% to 78% and 31% to 57% of the controls respectively, corresponding to a vitreous state. For the distant mode, very low conversion values were found (0–7% of the controls), with untraceable indentations. It can be concluded that low translucency veneers reduce conversion of VLAs, which can be improved by using touch-cure activators. Tack-curing, as instructed, creates vitrified materials, resulting in difficult removal of set excess, which implies the need for better standardization of the procedure.
- Open Access
Modern Light-Cured Restorative Composites as Luting Agents: The Effect of Preheating on Conversion and Film Thickness
The aim of this study was to evaluate (a) the degree of conversion (DC%), (b) film thickness, and (c) the effect of film thickness on DC% in modern light-cured resin composite restoratives [Filtek Universal (F), Clearfil Majesty ES 2 Universal (M), Tetric EvoCeram (T) and Viscalor (V)] used for luting composite onlays before/after preheating. For (a), the luting composites placed at 150 μm film thickness under the onlays (4 mm thickness, 2.9% transmittance) were light-cured for 120 s (3 × 40 s top, buccal, lingual sites) before and after preheating (54 °C/5 min-F,M,T and 65 °C/30 s-V). The DC% was measured at central, middle and side locations along the median in-length axis by ATR-FTIR spectroscopy. Specimens polymerized without onlays (40 s, top) served as controls. For (b), film thickness was measured employing a modified ISO 4049 standard (37 °C plate temperature, 5 N load) before and after preheating, using a dual-cured resin luting agent as control. For (c), onlays were luted with preheated T at 150 and 350 μm film thickness and light-cured for 2 × (3 × 40) s and 3 × (3 × 40) s, employing directly irradiated specimens (60 s, 120 s) as controls. For (a), significant differences were found in F and T before and after preheating. Before preheating, significant differences were registered between F–T, F–M, F–V and V–T, whereas after they were registered between F–M, F–T and F–V. All these values were significantly lower than the controls. For (b), significantly lower film thickness was recorded after preheating (−16.1–−33.3%, highest in V), with a ranking of F, M > V > T (before) and F, M > T, V (after). All values were significantly higher than the control. For (c), increased exposure improved DC% in the greater spacer group, with the controls providing superior values. It can be concluded that the use of modern highly filled composites as luting agents for low translucency onlays may result in suboptimal polymerization and film thickness, warranting caution.
Open AccessModern Light-Cured Restorative Composites as Luting Agents: The Effect of Preheating on Conversion and Film Thickness
The aim of this study was to evaluate (a) the degree of conversion (DC%), (b) film thickness, and (c) the effect of film thickness on DC% in modern light-cured resin composite restoratives [Filtek Universal (F), Clearfil Majesty ES 2 Universal (M), Tetric EvoCeram (T) and Viscalor (V)] used for luting composite onlays before/after preheating. For (a), the luting composites placed at 150 μm film thickness under the onlays (4 mm thickness, 2.9% transmittance) were light-cured for 120 s (3 × 40 s top, buccal, lingual sites) before and after preheating (54 °C/5 min-F,M,T and 65 °C/30 s-V). The DC% was measured at central, middle and side locations along the median in-length axis by ATR-FTIR spectroscopy. Specimens polymerized without onlays (40 s, top) served as controls. For (b), film thickness was measured employing a modified ISO 4049 standard (37 °C plate temperature, 5 N load) before and after preheating, using a dual-cured resin luting agent as control. For (c), onlays were luted with preheated T at 150 and 350 μm film thickness and light-cured for 2 × (3 × 40) s and 3 × (3 × 40) s, employing directly irradiated specimens (60 s, 120 s) as controls. For (a), significant differences were found in F and T before and after preheating. Before preheating, significant differences were registered between F–T, F–M, F–V and V–T, whereas after they were registered between F–M, F–T and F–V. All these values were significantly lower than the controls. For (b), significantly lower film thickness was recorded after preheating (−16.1–−33.3%, highest in V), with a ranking of F, M > V > T (before) and F, M > T, V (after). All values were significantly higher than the control. For (c), increased exposure improved DC% in the greater spacer group, with the controls providing superior values. It can be concluded that the use of modern highly filled composites as luting agents for low translucency onlays may result in suboptimal polymerization and film thickness, warranting caution.
- 13 June 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Surface, Microstructural, and Mechanical Characterization of Abutment Screws With Modified Surface Characteristics
Purpose: This study aimed to characterize the microstructural, mechanical, and surface properties of abutment screws with modified surface characteristics.Methods: Five anodized abutment screws of different coloration (green, purple, yellow, blue, brown), one Diamond‐like carbon (DLC)‐coated screw, one gold‐alloy screw, one gold‐coated screw, and one uncoated screw were used. Surface roughness parameters (Sa, Sq, Ssk, Sku, Spk, Sk, and Svk) were assessed by an optical profiler. Microstructural observations and elemental analysis were conducted with a scanning electron microscope (SEM) equipped with energy dispersive X‐ray detector (EDX). Martens Hardness (HM) and Indentation Elastic Modulus (EIT) were evaluated using Ιnstrumented Ιndentation Testing (IIT) employing a nanoindentation testing device. One‐way ANOVA and Tukey post hoc tests were performed for statistical analyses (a = 0.05).Results: SEM–EDX analysis demonstrated differences in microstructure and elemental composition on the bulk and the surface of abutment screws tested. Statistically significant differences were found for all surface roughness parameters and mechanical properties tested. The green anodized screw demonstrated significantly higher Sa, Sq, Spk, and Svk values, while the gold‐coated screw had significantly higher HM and EIT.Conclusions: The examined abutment screws displayed significant variations in the properties assessed, indicating that these differences may lead to variations in their clinical performance.
- 13 June 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Surface, Microstructural, and Mechanical Characterization of Abutment Screws With Modified Surface Characteristics
Purpose: This study aimed to characterize the microstructural, mechanical, and surface properties of abutment screws with modified surface characteristics.Methods: Five anodized abutment screws of different coloration (green, purple, yellow, blue, brown), one Diamond‐like carbon (DLC)‐coated screw, one gold‐alloy screw, one gold‐coated screw, and one uncoated screw were used. Surface roughness parameters (Sa, Sq, Ssk, Sku, Spk, Sk, and Svk) were assessed by an optical profiler. Microstructural observations and elemental analysis were conducted with a scanning electron microscope (SEM) equipped with energy dispersive X‐ray detector (EDX). Martens Hardness (HM) and Indentation Elastic Modulus (EIT) were evaluated using Ιnstrumented Ιndentation Testing (IIT) employing a nanoindentation testing device. One‐way ANOVA and Tukey post hoc tests were performed for statistical analyses (a = 0.05).Results: SEM–EDX analysis demonstrated differences in microstructure and elemental composition on the bulk and the surface of abutment screws tested. Statistically significant differences were found for all surface roughness parameters and mechanical properties tested. The green anodized screw demonstrated significantly higher Sa, Sq, Spk, and Svk values, while the gold‐coated screw had significantly higher HM and EIT.Conclusions: The examined abutment screws displayed significant variations in the properties assessed, indicating that these differences may lead to variations in their clinical performance.
- 17 July 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 136, 104623
In vitro evaluation of CAD/CAM composite materials
- 17 July 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 136, 104623
In vitro evaluation of CAD/CAM composite materials
- 13 January 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 130, 104423
Effect of aging on color, gloss and surface roughness of CAD/CAM composite materials
- 13 January 2023
- Published by Elsevier in Journal of Dentistry
- Vol. 130, 104423
Effect of aging on color, gloss and surface roughness of CAD/CAM composite materials