CTColten Tognazzini

Colten Tognazzini

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Colten Tognazzini has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The ratio between SARS-CoV-2 RNA viral load and culturable viral titre differs depending on the stage of infection: a case study of household transmission in an adult male

    by Michael K. Porter, Alexander Viloria Winnett, Linhui Hao, Natasha Shelby, Jessica A. Reyes, Noah W. Schlenker, Anne E. Romano, Colton Tognazzini, Matthew Feaster, Ying-Ying Goh, et al.

    Effective public health measures for communicable diseases rely on the ability to identify infectious individuals and prevent transmission from those individuals. For severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the presence of replication-competent virus in specimens from an individual is the gold standard for confirming infectiousness. However, viral culture from clinical specimens is difficult and infrequently performed. Instead, infectiousness may be inferred based on the abundance of viral RNA (or viral load) in a specimen, which is more easily assessed. For this reason, understanding the relationship between RNA viral load and infectious viral titre has important implications for public health strategy. In this case report, we quantified incident, longitudinal SARS-CoV-2 viral loads collected from saliva and nasal-swab specimens, and viral titre from nasal-swab specimens. We observed that the relationship between viral load and viral titre decreases by over five orders of magnitude throughout the course of the infection. Our work demonstrates the potential for infectious virus even in specimens with low viral loads collected during the early phases of infection.


  • Open Access

    The ratio between SARS-CoV-2 RNA viral load and culturable viral titer differs depending on stage of infection: case study of household transmission in an adult male

    by Michael K Porter, Alexander Viloria Winnett, Linhui Hao, Natasha Shelby, Jessica A Reyes, Noah W Schlenker, Anne E Romano, Colton Tognazzini, Matthew Feaster, Ying-Ying Goh, et al.

    Effective public health measures for communicable diseases rely on the ability to identify infectious individuals and prevent transmission from those individuals. For SARS-CoV-2, the presence of replication-competent virus in specimens from an individual is the gold standard for confirming infectiousness. However, viral culture from clinical specimens is difficult and infrequently performed. Instead, infectiousness may be inferred based on the abundance of viral RNA (or viral load) in a specimen, which is more easily assessed. For this reason, understanding the relationship between RNA viral load and infectious viral titer has important implications for public health strategy. In this case report, we quantified incident, longitudinal SARS-CoV-2 viral loads collected from saliva and nasal-swab specimens, and viral titer from nasal-swab specimens. We observed that the relationship between viral load and viral titer decreases by over five orders of magnitude throughout the course of the infection. Our work demonstrates the potential for infectious virus even in specimens with low viral loads collected during the early phases of infection.

  • Open Access

    The ratio between SARS-CoV-2 RNA viral load and culturable viral titer differs depending on stage of infection

    by Michael K Porter, Alexander Viloria Winnett, Linhui Hao, Natasha Shelby, Jessica A Reyes, Noah W Schlenker, Anne E Romano, Colton Tognazzini, Matthew Feaster, Ying-Ying Goh, et al.

    Analysis of incident, longitudinal RNA viral loads in saliva and nasal swabs and culturable viral titers in nasal swabs collected twice-daily by a tricenarian male infected with SARS-CoV-2 revealed the ratio between viral load and viral titer can be five orders of magnitude higher during early infection than late infection.

  • Open Access

    Index cases first identified by nasal-swab rapid COVID-19 tests had more transmission to household contacts than cases identified by other test types

    by Jenny Ji, Alexander Viloria Winnett, Natasha Shelby, Jessica A. Reyes, Noah W. Schlenker, Hannah Davich, Saharai Caldera, Colten Tognazzini, Ying-Ying Goh, Matt Feaster, et al.

    At-home rapid COVID-19 tests in the U.S. utilize nasal-swab specimens and require high viral loads to reliably give positive results. Longitudinal studies from the onset of infection have found infectious virus can present in oral specimens days before nasal. Detection and initiation of infection-control practices may therefore be delayed when nasal-swab rapid tests are used, resulting in greater transmission to contacts. We assessed whether index cases first identified by rapid nasal-swab COVID-19 tests had more transmission to household contacts than index cases who used other test types (tests with higher analytical sensitivity and/or non-nasal specimen types). In this observational cohort study, 370 individuals from 85 households with a recent COVID-19 case were screened at least daily by RT-qPCR on one or more self-collected upper-respiratory specimen types. A two-level random intercept model was used to assess the association between the infection outcome of household contacts and each covariable (household size, race/ethnicity, age, vaccination status, viral variant, infection-control practices, and whether a rapid nasal-swab test was used to initially identify the household index case). Transmission was quantified by adjusted secondary attack rates (aSAR) and adjusted odds ratios (aOR). An aSAR of 53.6% (95% CI 38.8–68.3%) was observed among households where the index case first tested positive by a rapid nasal-swab COVID-19 test, which was significantly higher than the aSAR for households where the index case utilized another test type (27.2% 95% CI 19.5–35.0%, P = 0.003 pairwise comparisons of predictive margins). We observed an aOR of 4.90 (95% CI 1.65–14.56) for transmission to household contacts when a nasal-swab rapid test was used to identify the index case, compared to other test types. Use of nasal-swab rapid COVID-19 tests for initial detection of infection and initiation of infection control may be less effective at limiting transmission to household contacts than other test types.


  • Open Access

    Daily SARS-CoV-2 Nasal Antigen Tests Miss Infected and Presumably Infectious People Due to Viral Load Differences among Specimen Types

    by Alexander Viloria Winnett, Reid Akana, Natasha Shelby, Hannah Davich, Saharai Caldera, Taikun Yamada, John Raymond B. Reyna, Anna E. Romano, Alyssa M. Carter, Mi Kyung Kim, et al.

    We reveal three findings from a longitudinal study of daily nasal antigen rapid diagnostic test (Ag-RDT) evaluated against SARS-CoV-2 viral load quantification in three specimen types (saliva, nasal swab, and throat swab) in participants enrolled at the incidence of infection. First, the evaluated Ag-RDT showed low (44%) clinical sensitivity for detecting infected persons at all infection stages.


  • Open Access

    The ratio between SARS-CoV-2 RNA viral load and culturable viral titer differs depending on stage of infection

    by Michael K. Porter, Alexander Viloria Winnett, Linhui Hao, Natasha Shelby, Jessica A. Reyes, Noah W. Schlenker, Anna E. Romano, Colton Tognazzini, Matthew Feaster, Ying-Ying Goh, et al.

    Analysis of incident, longitudinal RNA viral loads in saliva and nasal swabs and culturable viral titers in nasal swabs collected twice-daily by a tricenarian male infected with SARS-CoV-2 revealed the ratio between viral load and viral titer can be five orders of magnitude higher during early infection than late infection.

  • Open Access

    Index Cases First Identified by Nasal-Swab Rapid COVID-19 Tests Had More Transmission to Household Contacts Than Cases Identified by Other Test Types

    by Jenny Ji, Alexander Viloria Winnett, Natasha Shelby, Jessica A. Reyes, Noah W. Schlenker, Hannah Davich, Saharai Caldera, Colten Tognazzini, Ying-Ying Goh, Matt Feaster, et al.

    Importance: At-home rapid COVID-19 tests utilize nasal-swab specimens and require high viral loads to reliably give positive results. Longitudinal studies from the onset of infection have found infectious virus can present in oral specimens days before nasal. Detection and initiation of infection-control practices may therefore be delayed when nasal-swab rapid tests are used, resulting in greater exposure and transmission to contacts. Objective: We assessed whether index cases first identified by rapid nasal-swab COVID-19 tests had more transmission to household contacts than index cases who used other test types (tests with higher analytical sensitivity but longer turnaround times, and/or that utilize non-nasal specimen types). Design: In this observational cohort study, members of households with a recent COVID-19 case were screened for infection at least daily by RT-qPCR on one or more self-collected upper-respiratory specimen types. Participants reported demographic/medical information (including COVID-19 testing), symptom and exposure information, and household infection-control practices. A two-level random intercept model was used to assess the association between the infection outcome of household contacts and each covariable (household size, race/ethnicity, age, vaccination status, viral variant, infection-control practices, and whether a rapid nasal-swab test was used to initially identify the household index case). Setting: Southern California, September 2020—June 2021 and November 2021—March 2022. Participants: Cohort of 370 individuals from 85 households. Main Outcome(s) and Measure(s): Transmission was quantified by adjusted secondary attack rates (aSAR) and adjusted odds ratios (aOR). Results: An aSAR of 53.6% (95% CI 38.8–68.3%) was observed among households where the index case first tested positive by a rapid nasal-swab COVID-19 test, which was significantly higher than the aSAR for households where the index case utilized another test type (27.2% 95% CI 19.5– 35.0%, P =0.003 pairwise comparisons of predictive margins). We observed an aOR of 4.90 (95% CI 1.65–14.56) for transmission to household contacts when a nasal-swab rapid test was used to identify the index case, compared to other test types. Conclusions and Relevance: Use of nasal-swab rapid COVID-19 tests for initial detection of infection and initiation of infection control may not limit transmission as well as other test types. Key Points: 1. Question: Does identification of index cases by rapid nasal-swab tests limit household transmission of SARS-CoV-2 as well as other test types? 2. Finding: Significantly higher adjusted secondary attack rates and adjusted odds ratios for transmission were observed in households where the index case used a nasal rapid COVID-19 test for initial detection versus other test types. 3. Meaning: The use of nasal-swab rapid COVID-19 tests for initial detection of infection and initiation of infection control may not limit transmission as well as other test types.


  • Open Access

    Extreme differences in SARS-CoV-2 viral loads among respiratory specimen types during presumed pre-infectious and infectious periods

    by Alexander Viloria Winnett, Reid Akana, Natasha Shelby, Hannah Davich, Saharai Caldera, Taikun Yamada, John Raymond B Reyna, Anna E Romano, Alyssa M Carter, Mi Kyung Kim, et al.

    SARS-CoV-2 viral-load measurements from a single-specimen type are used to establish diagnostic strategies, interpret clinical-trial results for vaccines and therapeutics, model viral transmission, and understand virus–host interactions. However, measurements from a single-specimen type are implicitly assumed to be representative of other specimen types. We quantified viral-load timecourses from individuals who began daily self-sampling of saliva, anterior-nares (nasal), and oropharyngeal (throat) swabs before or at the incidence of infection with the Omicron variant. Viral loads in different specimen types from the same person at the same timepoint exhibited extreme differences, up to 109 copies/mL. These differences were not due to variation in sample self-collection, which was consistent. For most individuals, longitudinal viral-load timecourses in different specimen types did not correlate. Throat-swab and saliva viral loads began to rise as many as 7 days earlier than nasal-swab viral loads in most individuals, leading to very low clinical sensitivity of nasal swabs during the first days of infection. Individuals frequently exhibited presumably infectious viral loads in one specimen type while viral loads were low or undetectable in other specimen types. Therefore, defining an individual as infectious based on assessment of a single-specimen type underestimates the infectious period, and overestimates the ability of that specimen type to detect infectious individuals. For diagnostic COVID-19 testing, these three single-specimen types have low clinical sensitivity, whereas a combined throat–nasal swab, and assays with high analytical sensitivity, was inferred to have significantly better clinical sensitivity to detect presumed pre-infectious and infectious individuals.


  • Open Access

    Extreme differences in SARS-CoV-2 viral loads among respiratory specimen types during presumed pre-infectious and infectious periods

    by Alexander Viloria Winnett, Reid Akana, Natasha Shelby, Hannah Davich, Saharai Caldera, Taikun Yamada, John Raymond B. Reyna, Anna E. Romano, Alyssa M. Carter, Mi Kyung Kim, et al.

    SARS-CoV-2 viral load measurements from a single specimen type are used to establish diagnostic strategies, interpret clinical-trial results for vaccines and therapeutics, model viral transmission, and understand virus-host interactions. However, measurements from a single specimen type are implicitly assumed to be representative of other specimen types. We quantified viral-load timecourses from individuals who began daily self-sampling of saliva, anterior nares (nasal), and oropharyngeal (throat) swabs before or at the incidence of infection with the Omicron variant. Viral loads in different specimen types from the same person at the same timepoint exhibited extreme differences, up to 10 9 copies/mL. These differences were not due to variation in sample self-collection, which was consistent. For most individuals, longitudinal viral-load timecourses in different specimen types did not correlate. Throat-swab and saliva viral loads began to rise up to 7 days earlier than nasal-swab viral loads in most individuals, leading to very low clinical sensitivity of nasal swabs during the first days of infection. Individuals frequently exhibited presumably infectious viral loads in one specimen type while viral loads were low or undetectable in other specimen types. Therefore, defining an individual as infectious based on assessment of a single specimen type underestimates the infectious period, and overestimates the ability of that specimen type to detect infectious individuals. For diagnostic COVID-19 testing, these three single specimen types have low clinical sensitivity, whereas a combined throat-nasal swab, and assays with high analytical sensitivity, were inferred to have significantly better clinical sensitivity to detect presumed pre-infectious and infectious individuals. Significance Statement: In a longitudinal study of SARS-CoV-2 Omicron viral loads in three paired specimen types (saliva, anterior-nares swabs, and oropharyngeal swabs), we found extreme differences among paired specimen types collected from a person at the same timepoint, and that viral loads in different specimen types from the same person often do not correlate throughout infection. Individuals often exhibited high, presumably infectious viral loads in oral specimen types before nasal viral loads remained low or even undetectable. Combination oropharyngeal-nasal swabs were inferred to have superior clinical sensitivity to detect infected and infectious individuals. This demonstrates that single specimen type reference standard tests for SARS-CoV-2, such as in clinical trials or diagnostics evaluations may miss infected and even infectious individuals.


  • Open Access

    Why Daily SARS-CoV-2 Nasal Rapid Antigen Testing Poorly Detects Infected and Infectious Individuals

    by Alexander Viloria Winnett, Reid Akana, Natasha Shelby, Hannah Davich, Saharai Caldera, Taikun Yamada, John Raymond B. Reyna, Anna E. Romano, Alyssa M. Carter, Mi Kyung Kim, et al.

    Background: In a recent household-transmission study of SARS-CoV-2, we found extreme differences in SARS-CoV-2 viral loads among paired saliva, anterior-nares swab (ANS) and oropharyngeal swab specimens collected from the same timepoint. We hypothesized these differences may hinder low-analytical-sensitivity assays (including antigen rapid diagnostic tests, Ag-RDTs) using a single specimen type (e.g., ANS) from reliably detecting infected and infectious individuals. Methods: We evaluated a daily at-home ANS Ag-RDT (Quidel QuickVue) in a cross-sectional analysis of 228 individuals and in a longitudinal analysis (throughout infection) of 17 individuals enrolled early in the course of infection. Ag-RDT results were compared to RT-qPCR results and high, presumably infectious viral loads (in each, or any, specimen type). Results: The ANS Ag-RDT correctly detected only 44% of timepoints from infected individuals on cross-sectional analysis, and in this population had an inferred limit of detection of 7.6×10 6 copies/mL. From the longitudinal cohort, daily Ag-RDT clinical sensitivity was very low (<3%) during the early, pre-infectious period of the infection. Further, the Ag-RDT detected ≤63% of presumably infectious timepoints. The poor observed clinical sensitivity of the Ag-RDT was similar to what was predicted based on quantitative ANS viral loads and the inferred limit of detection of the ANS Ag-RDT being evaluated, indicating high-quality self-sampling. Conclusion: Nasal Ag-RDTs, even when used daily, can miss individuals infected with the Omicron variant and even those presumably infectious. Evaluations of Ag-RDT detection of infected or infectious individuals should be compared with a composite (multi-specimen) infection status to correctly assess performance. Key points: Nasal-swab rapid antigen tests have low analytical sensitivity and the sampling of only the nasal cavity hinders their ability to detect infected individuals, including those with high and presumably infectious viral loads in throat or saliva specimens.