Tianheng Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tianheng Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Dezhi Li
China Electric Power Research Institute, Beijing 100192, China
1 shared publication - Hongyin Chen
China Electric Power Research Institute Co., Ltd., Beijing 100192, China
1 shared publication - Ming Zhong
State Key Laboratory of Power Grid Safety, Beijing 100192, China
1 shared publication - Songcen Wang
Key Laboratory of Power Grid Safety and Energy Conservation China Electric Power Research Institute Beijing, China
1 shared publication - Xianxu Huo
State Grid Tianjin Electric Power Company, Tianjin 300010, China
1 shared publication - Ye Li
State Grid Tianjin Electric Power Company, Tianjin 300010, China
1 shared publication
Latest Publications
- Open Access
Numerical Investigation of Thermal Performance with Adaptive Terminal Devices for Cold Aisle Containment in Data Centers
The energy consumption of data center cooling systems accounts for a large proportion of total energy consumption. The optimization of airflow organization is one of the most important methods to improve the energy efficiency of cooling systems. The adjustment scale of many current air flow organization methods, however, is too large and does not support the data center’s refined operation. In this paper, a new type of air supply terminal device is proposed, and it could adaptively adjust according to the power of servers in the rack for cold air redistribution. In addition, the corresponding regulation strategy is proposed. A CFD model is established according to field investigation of a real data center in Shanghai to investigate the adjustment range and the energy saving potential of the device. The simulation results indicate that the device can suppress the local hot spots caused by excessive server power to some extent and greatly improve the uniformity of servers exhaust temperature. The case study shows that the device can save energy consumption by 20.1% and 4.2% in mitigating local hot spots compared with reducing supply air temperature and increasing supply air flowrate.
Open AccessNumerical Investigation of Thermal Performance with Adaptive Terminal Devices for Cold Aisle Containment in Data Centers
The energy consumption of data center cooling systems accounts for a large proportion of total energy consumption. The optimization of airflow organization is one of the most important methods to improve the energy efficiency of cooling systems. The adjustment scale of many current air flow organization methods, however, is too large and does not support the data center’s refined operation. In this paper, a new type of air supply terminal device is proposed, and it could adaptively adjust according to the power of servers in the rack for cold air redistribution. In addition, the corresponding regulation strategy is proposed. A CFD model is established according to field investigation of a real data center in Shanghai to investigate the adjustment range and the energy saving potential of the device. The simulation results indicate that the device can suppress the local hot spots caused by excessive server power to some extent and greatly improve the uniformity of servers exhaust temperature. The case study shows that the device can save energy consumption by 20.1% and 4.2% in mitigating local hot spots compared with reducing supply air temperature and increasing supply air flowrate.