Ahmed Abdelmonem Darweesh
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed Abdelmonem Darweesh has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Ashraf F. Barakat
Department of Oncology and Nuclear Medicine, Faculty of Medicine, Tanta University, Tanta, Egypt
1 shared publication- Ekhlas Abdelmonem Ibrahem Nasr Shaban
Department of Radiodiagnosis and Medical Imaging, Faculty of Medicine, Tanta University, Tanta, Egypt
1 shared publication - Marco Tadrous
EL Menshawy General Hospital, Tanta, Egypt
1 shared publication Mohamed Fathy Dawoud
Department of Radiodiagnosis and Medical Imaging, Faculty of Medicine, Tanta University, Tanta, Egypt
1 shared publication
Latest Publications
- Open Access
- 2 January 2024
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 55 (1) , 1-4
Closed bowel loop obstruction by a fibrous band mimicking paraduodenal hernia
Background: A closed-loop obstruction occurs when a section of the intestine becomes blocked at two locations along its pathway, increasing the likelihood of volvulus and ischemia. Frequently, a single adhesive band is the primary cause of a closed loop, although internal hernias from congenital defects or iatrogenic intervention in the mesentery or omentum can also become other factors. In closed-loop obstruction, computed tomography (CT) often displays a distinctive pattern where the bowel appears dilated and filled with fluid, forming a ‘C-shaped’ configuration. Case presentation: A 43-year-old female patient presented to the emergency department complaining of acute abdominal pain and repeated bilious vomiting with no history of absolute constipation. By examination, there were tenderness, guarding and rigidity. Her medical history includes type 1 diabetes since the age of 9 years and her surgical history included a onetime cesarean section and negative history of laparoscopic interventions. Ultrasound was done as a first-line investigation. It showed a few dilated bowel loops in addition to moderate intraperitoneal free fluid and could not detect the cause of bowel dilatation; therefore, non-contrast CT scan was requested and revealed the following findings: Two bowel loops exhibited distension and mucosal edema, and the configuration of bowel loops resembled a distinctive C-shape. Conclusion: Distinguishing between adhesive small bowel obstruction (SBO) and paraduodenal hernia relies on clinical history, imaging features, and risk factors. Adhesive SBO often stems from prior surgery or inflammation and may exhibit ‘beak’ or ‘whorl’ signs on CT scans.
- 2 January 2024
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 55 (1) , 1-4
Open AccessClosed bowel loop obstruction by a fibrous band mimicking paraduodenal hernia
Background: A closed-loop obstruction occurs when a section of the intestine becomes blocked at two locations along its pathway, increasing the likelihood of volvulus and ischemia. Frequently, a single adhesive band is the primary cause of a closed loop, although internal hernias from congenital defects or iatrogenic intervention in the mesentery or omentum can also become other factors. In closed-loop obstruction, computed tomography (CT) often displays a distinctive pattern where the bowel appears dilated and filled with fluid, forming a ‘C-shaped’ configuration. Case presentation: A 43-year-old female patient presented to the emergency department complaining of acute abdominal pain and repeated bilious vomiting with no history of absolute constipation. By examination, there were tenderness, guarding and rigidity. Her medical history includes type 1 diabetes since the age of 9 years and her surgical history included a onetime cesarean section and negative history of laparoscopic interventions. Ultrasound was done as a first-line investigation. It showed a few dilated bowel loops in addition to moderate intraperitoneal free fluid and could not detect the cause of bowel dilatation; therefore, non-contrast CT scan was requested and revealed the following findings: Two bowel loops exhibited distension and mucosal edema, and the configuration of bowel loops resembled a distinctive C-shape. Conclusion: Distinguishing between adhesive small bowel obstruction (SBO) and paraduodenal hernia relies on clinical history, imaging features, and risk factors. Adhesive SBO often stems from prior surgery or inflammation and may exhibit ‘beak’ or ‘whorl’ signs on CT scans.
- Open Access
- 17 January 2023
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 54 (1) , 1-11
Diagnostic value of positron emission tomography/computed tomography (PET/CT) in detection of peritoneal carcinomatosis
Background: The diagnosis of peritoneal carcinomatosis is challenging and can be difficult to detect with imaging, especially the detection of small-sized peritoneal lesions. The presence of peritoneal neoplastic spread alters tumour staging and is one of the most significant prognostic indicators in several malignancies, and the purpose of this study was to highlight the diagnostic value of PET/CT in detection of peritoneal carcinomatosis in patients with malignant neoplastic disease. Results: PET/CT has 76.2% sensitivity, 88.9% specificity, 94.1% PPV, 61.5% NPV and 80% accuracy in detection of peritoneal carcinomatosis. Different patterns of FDG uptake of peritoneal carcinomatosis were found such as focal nodular uptake, diffuse abdominal uptake and liver surface focal or diffuse uptake. From all these different patterns, focal nodular uptake was the most frequent pattern. The best cut-off value of SUVmax was 5 for diagnosis. Conclusions: The study affirms the significant role of PET/CT in the diagnosis of peritoneal carcinomatosis and its important value in the staging, management and follow-up of patients with secondary peritoneal malignancies, especially in case of unavailable or inappropriate peritoneal biopsy. Therefore, PET/CT could help reduce the number of laparotomies and a better selection of patients who are candidates for adjuvant chemotherapy.
- 17 January 2023
- Published by Springer Nature in Egyptian Journal of Radiology and Nuclear Medicine
- Vol. 54 (1) , 1-11
Open AccessDiagnostic value of positron emission tomography/computed tomography (PET/CT) in detection of peritoneal carcinomatosis
Background: The diagnosis of peritoneal carcinomatosis is challenging and can be difficult to detect with imaging, especially the detection of small-sized peritoneal lesions. The presence of peritoneal neoplastic spread alters tumour staging and is one of the most significant prognostic indicators in several malignancies, and the purpose of this study was to highlight the diagnostic value of PET/CT in detection of peritoneal carcinomatosis in patients with malignant neoplastic disease. Results: PET/CT has 76.2% sensitivity, 88.9% specificity, 94.1% PPV, 61.5% NPV and 80% accuracy in detection of peritoneal carcinomatosis. Different patterns of FDG uptake of peritoneal carcinomatosis were found such as focal nodular uptake, diffuse abdominal uptake and liver surface focal or diffuse uptake. From all these different patterns, focal nodular uptake was the most frequent pattern. The best cut-off value of SUVmax was 5 for diagnosis. Conclusions: The study affirms the significant role of PET/CT in the diagnosis of peritoneal carcinomatosis and its important value in the staging, management and follow-up of patients with secondary peritoneal malignancies, especially in case of unavailable or inappropriate peritoneal biopsy. Therefore, PET/CT could help reduce the number of laparotomies and a better selection of patients who are candidates for adjuvant chemotherapy.