Yue Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yue Pan has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Xiping Xu
3 shared publications- Xiping Xu
School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China
3 shared publications - Kailin Zhang
School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China
2 shared publications Mai Hu
Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, 3888 Dong Nanhu Rd, Changchun 130022, Peoples R China
2 shared publications- Motong Hu
Changchun Univ Sci & Technol, Coll Optoelect Engn, Changchun 130022, Jilin, Peoples R China
2 shared publications Yuanming Zhao
27th Res Inst China Elect Technol Grp Corp, 36 Boxue Rd, Zhengzhou 470000, Peoples R China
2 shared publications
Latest Publications
- Open Access
- 29 June 2026
- Published by Springer Nature in Journal of King Saud University Computer and Information Sciences
- Vol. 38 (6)
LWIR-HPE: a high-variance keypoint perception network for human pose estimation in weakly textured LWIR scenes
- 29 June 2026
- Published by Springer Nature in Journal of King Saud University Computer and Information Sciences
- Vol. 38 (6)
Open AccessLWIR-HPE: a high-variance keypoint perception network for human pose estimation in weakly textured LWIR scenes
- Open Access
Precision Calibration of Robot Magnetorheological Finishing System Based on Laser Tracker
Six-degree-of-freedom industrial robots, known for their low cost and high flexibility, have been extensively applied in optical processing. Precise pose control in robot-based optical processing systems depends on the accurate calibration of the tool coordinate system. However, in robot magnetorheological finishing (Robot-MRF) systems, the spherical shape of the polishing wheel poses significant challenges in precisely identifying the working point on the tool’s surface. Traditional calibration methods, such as the four-point or six-point techniques, fail to accurately calibrate the tool coordinate system for MRF tools. To overcome this limitation, a laser tracker-based calibration method is proposed for parameter calibration of the Robot-MRF system. Experimental results show that this method achieves a maximum repeatability error of just 0.0505 mm, significantly improving the stability and reliability of the calibration results and meeting the high-precision processing requirements of MRF technology.
Open AccessPrecision Calibration of Robot Magnetorheological Finishing System Based on Laser Tracker
Six-degree-of-freedom industrial robots, known for their low cost and high flexibility, have been extensively applied in optical processing. Precise pose control in robot-based optical processing systems depends on the accurate calibration of the tool coordinate system. However, in robot magnetorheological finishing (Robot-MRF) systems, the spherical shape of the polishing wheel poses significant challenges in precisely identifying the working point on the tool’s surface. Traditional calibration methods, such as the four-point or six-point techniques, fail to accurately calibrate the tool coordinate system for MRF tools. To overcome this limitation, a laser tracker-based calibration method is proposed for parameter calibration of the Robot-MRF system. Experimental results show that this method achieves a maximum repeatability error of just 0.0505 mm, significantly improving the stability and reliability of the calibration results and meeting the high-precision processing requirements of MRF technology.
- 7 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (6) , 10373-10391
Quaternary pulse width modulation based ultra-high frame rate scene projector used for hard-ware-in-the-loop testing
The scene projector (SP) can provide simulated scene images with same optical characteristics as the real scenes to evaluate imaging systems in hard-ware-in-the-loop (HWIL) simulation testing. The single scene generation device (SGD) based SP typically projects 8-bit images at 220 fps, which is insufficient to fulfill the requirements of ultra-high frame rate imaging systems, such as star trackers and space debris detectors. In this paper, an innovative quaternary pulse width modulation (PWM) based SP is developed and implemented to realize the ultra-high frame rate projection. By optically overlapping modulation layers of two digital micro-mirror devices (DMDs) in parallel, and illuminating them with light intensities, a quaternary SGD is built up to modulate quaternary digit-planes (QDs) with four grayscale levels. And the quaternary digit-plane de-composition (QDD) is adopted to decompose an 8-bit image into 4 QDs. In addition, the exposure time of each QD is controlled by quaternary PWM, and the base time is optimized to 8 µs. The experimental results prove that the total exposure time of all QDs sequentially modulated by quaternary PWM is approximately 760 µs, namely projecting 8-bit images at 1300 fps. The quaternary PWM using two DMDs in parallel dramatically improves the grayscale modulation efficiency compared to the existing projection technologies, which provides a new approach for the SP design with ultra-high frame rate.
- 7 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (6) , 10373-10391
Quaternary pulse width modulation based ultra-high frame rate scene projector used for hard-ware-in-the-loop testing
The scene projector (SP) can provide simulated scene images with same optical characteristics as the real scenes to evaluate imaging systems in hard-ware-in-the-loop (HWIL) simulation testing. The single scene generation device (SGD) based SP typically projects 8-bit images at 220 fps, which is insufficient to fulfill the requirements of ultra-high frame rate imaging systems, such as star trackers and space debris detectors. In this paper, an innovative quaternary pulse width modulation (PWM) based SP is developed and implemented to realize the ultra-high frame rate projection. By optically overlapping modulation layers of two digital micro-mirror devices (DMDs) in parallel, and illuminating them with light intensities, a quaternary SGD is built up to modulate quaternary digit-planes (QDs) with four grayscale levels. And the quaternary digit-plane de-composition (QDD) is adopted to decompose an 8-bit image into 4 QDs. In addition, the exposure time of each QD is controlled by quaternary PWM, and the base time is optimized to 8 µs. The experimental results prove that the total exposure time of all QDs sequentially modulated by quaternary PWM is approximately 760 µs, namely projecting 8-bit images at 1300 fps. The quaternary PWM using two DMDs in parallel dramatically improves the grayscale modulation efficiency compared to the existing projection technologies, which provides a new approach for the SP design with ultra-high frame rate.
- Open Access
A Review on Zernike Coefficient-Solving Algorithms (CSAs) Used for Integrated Optomechanical Analysis (IOA)
An integrated optomechanical analysis (IOA) can predict the response of an optomechanical system to temperature, gravity, vibrations, and other local loadings; thus, the normal operation of instruments under special conditions is guaranteed. Zernike polynomials are the most popular for fitting the IOA-derived mechanical deformation data. By solving the Zernike coefficients of all deformed optical surfaces, the relationship between aberrations and deformations can be further revealed. The process of IOA is summarized in this article. The principles of four primary Zernike coefficient-solving algorithms (CSAs) were expounded, and the corresponding applications are reviewed in detail, including the least squares method, the Gram–Schmidt orthogonalized method, the Householder transformation, and singular value decomposition (SVD). Artificial neural networks (ANNs) trained for solving a similar overdetermined set of equations are also discussed; an innovative Zernike CSA based on a one-dimensional convolutional neural network (1D-CNN) was proposed, emphasizing its potential for Zernike CSA. The feasibility of the neural network method was verified by conducting experiments on the primary mirror of the front reflection system of a space camera. This review can provide references for the precise optimization of IOA.
Open AccessA Review on Zernike Coefficient-Solving Algorithms (CSAs) Used for Integrated Optomechanical Analysis (IOA)
An integrated optomechanical analysis (IOA) can predict the response of an optomechanical system to temperature, gravity, vibrations, and other local loadings; thus, the normal operation of instruments under special conditions is guaranteed. Zernike polynomials are the most popular for fitting the IOA-derived mechanical deformation data. By solving the Zernike coefficients of all deformed optical surfaces, the relationship between aberrations and deformations can be further revealed. The process of IOA is summarized in this article. The principles of four primary Zernike coefficient-solving algorithms (CSAs) were expounded, and the corresponding applications are reviewed in detail, including the least squares method, the Gram–Schmidt orthogonalized method, the Householder transformation, and singular value decomposition (SVD). Artificial neural networks (ANNs) trained for solving a similar overdetermined set of equations are also discussed; an innovative Zernike CSA based on a one-dimensional convolutional neural network (1D-CNN) was proposed, emphasizing its potential for Zernike CSA. The feasibility of the neural network method was verified by conducting experiments on the primary mirror of the front reflection system of a space camera. This review can provide references for the precise optimization of IOA.
- 17 January 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 161
FEA based opto-mechanisms design and thermal analysis of a dynamic SFS with an ultra-long exit pupil distance
- 17 January 2023
- Published by Elsevier in Optics & Laser Technology
- Vol. 161
FEA based opto-mechanisms design and thermal analysis of a dynamic SFS with an ultra-long exit pupil distance
- 12 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11763, 117639V-468
Stray light test facility for multispectral spaced-based optical system with large field of view
In order to evaluate the ability of a space-based optical system to suppress off-axis stray light, a large-field, multispectrum space-based stray light test method based on point source transmittance (PST) is proposed in this paper. A stray light test facility is constructed using multiple laser sources, large aperture off-axis reflective parallel light tubes and a high-precision positioning mechanism to evaluate the PST index of stray light in the visible and near infrared bands for a space-based optical system. Based on theoretical analysis, experimental measurements of standard lenses in various wavelength bands have proven that the dynamic range of the facility in the visible light band is 10-6 and in the infrared band is 10-3. The facility has the advantages of wide range of detectable wavelengths, high automation, and large dynamic range. The test results can be used for correction of the hood, which provides a reliable traceability basis for the stray light suppression of a space-based optical system.
- 12 March 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11763, 117639V-468
Stray light test facility for multispectral spaced-based optical system with large field of view
In order to evaluate the ability of a space-based optical system to suppress off-axis stray light, a large-field, multispectrum space-based stray light test method based on point source transmittance (PST) is proposed in this paper. A stray light test facility is constructed using multiple laser sources, large aperture off-axis reflective parallel light tubes and a high-precision positioning mechanism to evaluate the PST index of stray light in the visible and near infrared bands for a space-based optical system. Based on theoretical analysis, experimental measurements of standard lenses in various wavelength bands have proven that the dynamic range of the facility in the visible light band is 10-6 and in the infrared band is 10-3. The facility has the advantages of wide range of detectable wavelengths, high automation, and large dynamic range. The test results can be used for correction of the hood, which provides a reliable traceability basis for the stray light suppression of a space-based optical system.