Maksym Falchenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Maksym Falchenko has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Mykola Ostroverkhov
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
2 shared publications - Denys Kolomiichuk
Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського
1 shared publication - Heorhii Veshchykov
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute
1 shared publication - Hryhorii Bolshakov
Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського
1 shared publication - Mykhailo Kovalenko
National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute
1 shared publication - Vadim Chumak
National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute
1 shared publication
Latest Publications
- Open Access
- 28 March 2024
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1
SPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR IN SLIDING MODE
The paper examines a series of speed control algorithms for a synchronous permanent magnet motor in sliding mode, providing asymptotic stability of the first, second, and third order. In the sliding mode, the control system exhibits properties that are unattainable with classical continuous control algorithms. The control algorithms are developed based on the inverse dynamics method combined with the minimization of local instantaneous energy functionals. The key idea of the method lies in the reversibility of the direct Lyapunov method for stability analysis. The closed-loop control system has a predefined Lyapunov function, represented by the instantaneous energy. Notably, the control algorithms do not require knowledge of the object's parameters or differentiation operations, which facilitates their practical implementation. The regulator parameters consist solely of coefficients used to specify the desired duration and shape of current and motor speed transient processes. The vector speed control system comprises two controllers for the stator current components and the motor speed controller. All regulators operate in sliding mode. The output signals of the stator current component controllers and speed vary discontinuously from maximum to minimum values. Simulation results demonstrate the effectiveness and high-quality performance of the control algorithms. To determine the control performance indicators for the three synthesized speed controllers, the motor startup trajectory is formed from characteristic segments of constant, linearly increasing, and parabolic signals. The speed control algorithm with a first-order asymptote ensures zero tracking error only for a constant reference signal. With a linearly increasing reference signal, the steady-state relative tracking error is 2,5 %, while for a parabolic reference signal, the error varies between zero and 2,5 %. The second-order asymptotic speed control algorithm ensures zero steady-state tracking error for constant and linearly increasing reference signals, and for a parabolic reference signal, the steady-state relative tracking error is 0,125 %. The third-order asymptotic speed control algorithm ensures zero steady-state tracking error for constant, linearly increasing, and parabolic reference signals, with a maximum dynamic relative tracking error of 0,05 %.
- 28 March 2024
- Published by Igor Sikorsky Kyiv Polytechnic Institute in POWER ENGINEERING: economics, technique, ecology
- No. 1
Open AccessSPEED CONTROL OF PERMANENT MAGNET SYNCHRONOUS MOTOR IN SLIDING MODE
The paper examines a series of speed control algorithms for a synchronous permanent magnet motor in sliding mode, providing asymptotic stability of the first, second, and third order. In the sliding mode, the control system exhibits properties that are unattainable with classical continuous control algorithms. The control algorithms are developed based on the inverse dynamics method combined with the minimization of local instantaneous energy functionals. The key idea of the method lies in the reversibility of the direct Lyapunov method for stability analysis. The closed-loop control system has a predefined Lyapunov function, represented by the instantaneous energy. Notably, the control algorithms do not require knowledge of the object's parameters or differentiation operations, which facilitates their practical implementation. The regulator parameters consist solely of coefficients used to specify the desired duration and shape of current and motor speed transient processes. The vector speed control system comprises two controllers for the stator current components and the motor speed controller. All regulators operate in sliding mode. The output signals of the stator current component controllers and speed vary discontinuously from maximum to minimum values. Simulation results demonstrate the effectiveness and high-quality performance of the control algorithms. To determine the control performance indicators for the three synthesized speed controllers, the motor startup trajectory is formed from characteristic segments of constant, linearly increasing, and parabolic signals. The speed control algorithm with a first-order asymptote ensures zero tracking error only for a constant reference signal. With a linearly increasing reference signal, the steady-state relative tracking error is 2,5 %, while for a parabolic reference signal, the error varies between zero and 2,5 %. The second-order asymptotic speed control algorithm ensures zero steady-state tracking error for constant and linearly increasing reference signals, and for a parabolic reference signal, the steady-state relative tracking error is 0,125 %. The third-order asymptotic speed control algorithm ensures zero steady-state tracking error for constant, linearly increasing, and parabolic reference signals, with a maximum dynamic relative tracking error of 0,05 %.
- Open Access
- 30 December 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 6 (5 (120)) , 6-17
Development of control algorithms for magnetoelectric generator with axial magnetic flux and double stator based on mathematical modeling
The object of this research is electromechanical processes in a generator with an axial magnetic flux and a double stator and an additional non-contact excitation winding operating as part of autonomous electric power systems. The power of the additional excitation system is about 2 % of the generator power. The presence of an additional non-contact winding, which is powered by direct current, makes it possible to control the generator voltage by changing the excitation current. This resolves the task to stabilize the output voltage of the generator with permanent magnets when the load and shaft speed change. This paper reports the construction of a three-dimensional field axisymmetric mathematical model of the generator under study, which has made it possible to calculate and investigate its characteristics and parameters, in particular the magnitude of magnetic induction in all structural elements. The model built takes into account the influence of finite effects, magnetic scattering fields, and the radial-axial nature of the closure of the main magnetic flux and the magnetic flux of the additional excitation winding. The use of a structure with a double stator makes it possible to more efficiently utilize the usable volume of the generator and to increase its power. A mathematical model of the generator in the d-q coordinate system was built, which has made it possible to synthesize algorithms for controlling the automatic voltage stabilization system of the generator voltage under conditions of change in load and shaft speed. Control algorithms were developed on the basis of the concept of inverse dynamics problems in combination with minimizing local functionalities of instantaneous energy values, which ensures that the system is robust when changing generator parameters and that regulators are implemented in a simple way, due to the lack of differentiation operations. Based on the models built and algorithms developed, the quality of control of the generator's output voltage when the load and frequency of the generator change was investigated by modeling in the MATLAB/Simulink environment. When setting a jump in the rated load and changing the rotational speed within ±15 % of the rated value, the automatic stabilization system provides astatic voltage control at a given level of 48 V. The results can be practically used in the design of autonomous electric power systems with high energy conversion efficiency, in particular wind turbines and hydraulic units
- 30 December 2022
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 6 (5 (120)) , 6-17
Open AccessDevelopment of control algorithms for magnetoelectric generator with axial magnetic flux and double stator based on mathematical modeling
The object of this research is electromechanical processes in a generator with an axial magnetic flux and a double stator and an additional non-contact excitation winding operating as part of autonomous electric power systems. The power of the additional excitation system is about 2 % of the generator power. The presence of an additional non-contact winding, which is powered by direct current, makes it possible to control the generator voltage by changing the excitation current. This resolves the task to stabilize the output voltage of the generator with permanent magnets when the load and shaft speed change. This paper reports the construction of a three-dimensional field axisymmetric mathematical model of the generator under study, which has made it possible to calculate and investigate its characteristics and parameters, in particular the magnitude of magnetic induction in all structural elements. The model built takes into account the influence of finite effects, magnetic scattering fields, and the radial-axial nature of the closure of the main magnetic flux and the magnetic flux of the additional excitation winding. The use of a structure with a double stator makes it possible to more efficiently utilize the usable volume of the generator and to increase its power. A mathematical model of the generator in the d-q coordinate system was built, which has made it possible to synthesize algorithms for controlling the automatic voltage stabilization system of the generator voltage under conditions of change in load and shaft speed. Control algorithms were developed on the basis of the concept of inverse dynamics problems in combination with minimizing local functionalities of instantaneous energy values, which ensures that the system is robust when changing generator parameters and that regulators are implemented in a simple way, due to the lack of differentiation operations. Based on the models built and algorithms developed, the quality of control of the generator's output voltage when the load and frequency of the generator change was investigated by modeling in the MATLAB/Simulink environment. When setting a jump in the rated load and changing the rotational speed within ±15 % of the rated value, the automatic stabilization system provides astatic voltage control at a given level of 48 V. The results can be practically used in the design of autonomous electric power systems with high energy conversion efficiency, in particular wind turbines and hydraulic units