Hui Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hui Zhang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Kai Wang
School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China
4 shared publicationsWendong Wang
School of Human Settlements and Civil Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
4 shared publicationsXue Zhou
School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, People's Republic of China
4 shared publicationsLuobin Wang
Key Laboratory of Northwest Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, China
3 shared publicationsShan Chang
Zhejiang Prov Inst Architectural Design & Res, Hangzhou, Zhejiang, Peoples R China
3 shared publications- Tinglin Huang
Field Scientific Observation and Research Station for Qinling Water Source Water Quality of Shaanxi Province, Xi'an University of Architecture and Technology, Xi'an, 710055, China; Shaanxi Key Laboratory of Environmental Engineering, Xi'an University of Architecture and Technology, Xi'an, 710055, China; Key Laboratory of Northwest Water Resource, Environment and Ecology, MOE, Xi'an University of Architecture and Technology, Xi'an, 710055, China
3 shared publications
Latest Publications
- 11 December 2025
- Published by Elsevier in Water Research
- Vol. 291, 125148
Using machine learning to predict heavy metal concentrations and induced health risks in drinking water distribution systems from key cities in China
- 11 December 2025
- Published by Elsevier in Water Research
- Vol. 291, 125148
Using machine learning to predict heavy metal concentrations and induced health risks in drinking water distribution systems from key cities in China
- 1 February 2023
- Published by Taylor & Francis in Innovations in Education and Teaching International
- Vol. 61 (4) , 665-674
Motivating municipal engineering students to learn computer language with integration of specialised design problems and programming
Computer programming and municipal engineering (ME) students’ specialised knowledge are still poorly integrated, leading to limited improvement of students’ programming abilities. This paper describes an effective attempt in ME at Xi’an University of Architecture and Technology (XAUAT). Students were divided into several teams and required to develop software tools for ME design problems using Visual C++ 6.0. In this teaching approach, students need to identify the solutions by integrating knowledge in mathematics, physics, chemistry, basic engineering science, and ME. Moreover, students should develop programmes with friendly interfaces, essential prompts, and reliable results. The example programmes, positive feedback from the survey, and better performance in the final examination proved that the students’ abilities of knowledge application and problem-solving had been developed, and their motivation in learning programming had been improved.
- 1 February 2023
- Published by Taylor & Francis in Innovations in Education and Teaching International
- Vol. 61 (4) , 665-674
Motivating municipal engineering students to learn computer language with integration of specialised design problems and programming
Computer programming and municipal engineering (ME) students’ specialised knowledge are still poorly integrated, leading to limited improvement of students’ programming abilities. This paper describes an effective attempt in ME at Xi’an University of Architecture and Technology (XAUAT). Students were divided into several teams and required to develop software tools for ME design problems using Visual C++ 6.0. In this teaching approach, students need to identify the solutions by integrating knowledge in mathematics, physics, chemistry, basic engineering science, and ME. Moreover, students should develop programmes with friendly interfaces, essential prompts, and reliable results. The example programmes, positive feedback from the survey, and better performance in the final examination proved that the students’ abilities of knowledge application and problem-solving had been developed, and their motivation in learning programming had been improved.
- 12 January 2023
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 31 (3) , 620-633
Integrating mobile learning and SPOC‐based flipped classroom to teach a course in water supply and drainage science and engineering
To promote the combination of mobile learning (m‐learning) in new courses contexts and improve students' learning outcomes, an integrated method of m‐learning and small private online course (SPOC)‐based flipped classroom was proposed and used for teaching the “hydrology” course at Xi'an University of Architecture and Technology (XAUAT). The offering of the new methodology was composed of preclass (knowledge acquisition), in‐class (knowledge internalization), and after‐class (knowledge application) stages, and the WeChat applet Mu classroom with m‐learning technology was adopted in the in‐class stage. To improve the teacher–student interactions and communication, several interactive activities were designed based on Mu classroom, including random roll calls, open questions, objective questions, discussion, and extended discussion. After using the integrated method, the average score of each final exam was improved significantly (p < .05), and the failed (p = .002 < .01). Positive correlation between the scores of in‐class quizzes and discussion and final exam were obtained (R2 = .530, p < .001), indicating that students' outcomes were greatly affected by mobile learning. Moreover, positive feedback from students' questionnaires confirmed that the integrated approach was effective and could motivate students' learning interests and knowledge understanding.
- 12 January 2023
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 31 (3) , 620-633
Integrating mobile learning and SPOC‐based flipped classroom to teach a course in water supply and drainage science and engineering
To promote the combination of mobile learning (m‐learning) in new courses contexts and improve students' learning outcomes, an integrated method of m‐learning and small private online course (SPOC)‐based flipped classroom was proposed and used for teaching the “hydrology” course at Xi'an University of Architecture and Technology (XAUAT). The offering of the new methodology was composed of preclass (knowledge acquisition), in‐class (knowledge internalization), and after‐class (knowledge application) stages, and the WeChat applet Mu classroom with m‐learning technology was adopted in the in‐class stage. To improve the teacher–student interactions and communication, several interactive activities were designed based on Mu classroom, including random roll calls, open questions, objective questions, discussion, and extended discussion. After using the integrated method, the average score of each final exam was improved significantly (p < .05), and the failed (p = .002 < .01). Positive correlation between the scores of in‐class quizzes and discussion and final exam were obtained (R2 = .530, p < .001), indicating that students' outcomes were greatly affected by mobile learning. Moreover, positive feedback from students' questionnaires confirmed that the integrated approach was effective and could motivate students' learning interests and knowledge understanding.
- Open Access
- 29 November 2022
- Published by Elsevier in Desalination and Water Treatment
- Vol. 271, 16-26
Corrosion inhibition of iron pipes in drinking water distribution systems by a nitrate-reducing bacterium with varied nitrate concentrations
- 29 November 2022
- Published by Elsevier in Desalination and Water Treatment
- Vol. 271, 16-26
Open AccessCorrosion inhibition of iron pipes in drinking water distribution systems by a nitrate-reducing bacterium with varied nitrate concentrations
- 20 September 2019
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 55 (1) , 63-70
Using disability-adjusted life years to estimate the cancer risks of low-level arsenic in drinking water
Recent studies have shown that long-term exposure to low-level arsenic (−4, and the total DALYs estimation for all age groups was 20.58 person-year. The average individual DALYs lost was 3.35 × 10−5 per person-year (ppy), which was 33.5 times the reference value (1.00 × 10−6 ppy). The mortality burden had a considerably larger contribution (97.31%) to the total disease burden, and the 60–65-year age group exhibited the largest DALYs lost. Skin cancer exhibited the largest burden of 2.15 × 10−5 ppy, followed by lung cancer (1.20 × 10−5 ppy). This study might be useful for potential strategies of risk control and management in XP drinking water.
- 20 September 2019
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 55 (1) , 63-70
Using disability-adjusted life years to estimate the cancer risks of low-level arsenic in drinking water
Recent studies have shown that long-term exposure to low-level arsenic (−4, and the total DALYs estimation for all age groups was 20.58 person-year. The average individual DALYs lost was 3.35 × 10−5 per person-year (ppy), which was 33.5 times the reference value (1.00 × 10−6 ppy). The mortality burden had a considerably larger contribution (97.31%) to the total disease burden, and the 60–65-year age group exhibited the largest DALYs lost. Skin cancer exhibited the largest burden of 2.15 × 10−5 ppy, followed by lung cancer (1.20 × 10−5 ppy). This study might be useful for potential strategies of risk control and management in XP drinking water.
- 1 November 2018
- Published by Elsevier in Water Research
- Vol. 145, 83-93
Estimating and comparing the cancer risks from THMs and low-level arsenic in drinking water based on disability-adjusted life years
- 1 November 2018
- Published by Elsevier in Water Research
- Vol. 145, 83-93
Estimating and comparing the cancer risks from THMs and low-level arsenic in drinking water based on disability-adjusted life years
- 16 August 2018
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 190 (9) , 524
Water quality characteristics and corrosion potential in blending zones in X city drinking water distribution system
Blended water, always existing in a drinking water distribution system (DWDS) with different sources, can cause some unintended results, including corrosion and/or release of corrosion by-products. Although some studies have specially focused on the blended water in DWDSs, the water quality characteristics, variations, and mechanisms for corrosion and metal release have not been fully understood. This study aims to examine the characteristics and evaluate the corrosion potential of blended water in X city DWDS using four indices of Langelier saturation index (LSI), Ryznar stability index (RSI), Puckorius scaling index (PSI), and calcium carbonate precipitation potential (CCPP). Physical and chemical analysis showed that the values of pH, total dissolved solids (TDS), sulfate (SO42−), and chloride (Cl−) in blended water were always at acceptable levels, while some free residual chlorine concentrations fell outside the regulatory standards (≥ 0.05 mg/L) with the minimum of 0.01 mg/L. Most parameters except pH varied in large ranges with maximum to minimum ratios (MMRs) over 2.25. The mean values of the LSI, RSI, PSI, and CCPP indices were − 0.44, 8.65, 8.79, and − 1.95 mg/L CaCO3, respectively, indicating that the blended water was slightly corrosive. For the three zones, Z2 had the highest mean levels of TDS (320.84 mg/L), alkalinity (188.70 mg/L CaCO3), SO42− (13.69 mg/L), Cl− (36.37 mg/L), calcium hardness (Ca2+) (28.99 mg/L), and magnesium hardness (Mg2+) (15.22 mg/L) and the lowest mean level of dissolved oxygen (DO) (6.72 mg/L). Thus, the corrosion potential in Z2 was the lowest with the LSI, RSI, PSI, and CCPP values of − 0.17, 8.11, 8.08, and 2.87 mg/L CaCO3, respectively. During a year, the corrosion in blended water was more serious in winter with the LSI, RSI, PSI, and CCPP indices of − 0.79, 9.25, 9.37, − 7.54 mg/L CaCO3, respectively. The water corrosivity reached the minimum level in summer (LSI − 0.12, RSI 8.05, PSI 8.03, and CCPP 5.22 mg/L CaCO3) owing to the decrease of DO concentrations and the increase of temperature and groundwater supplies with higher alkalinity. During rainy season, the concentrations of TDS, alkalinity, SO42−, Cl−, Ca2+, and Mg2+ in blended water were reduced by 41.05%, 40.48%, 35.83%, 47.48%, 23.47%, and 55.73%, respectively, resulting in the increase of water corrosivity. More decreases of water parameters were recorded in Z2 (TDS, 221.80 mg/L; alkalinity, 139.50 mg/L CaCO3; SO42−, 9.97 mg/L; Cl−, 13.74 mg/L; Ca2+, 7.10 mg/L; and Mg2+, 11.37 mg/L), because most groundwater from No. 5 WTP was pumped paretic water with more variations of water quality by rainfall. Moreover, it was suggested that Mg2+ should be considered in the corrosion indices, and the corrosion tendency of blended water could be reduced by adjusting the levels of pH, alkalinity, Ca2+, and Mg2+. The results of this research may pave the way for several opportunities to improve the management and corrosion prevention of blended water.
- 16 August 2018
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 190 (9) , 524
Water quality characteristics and corrosion potential in blending zones in X city drinking water distribution system
Blended water, always existing in a drinking water distribution system (DWDS) with different sources, can cause some unintended results, including corrosion and/or release of corrosion by-products. Although some studies have specially focused on the blended water in DWDSs, the water quality characteristics, variations, and mechanisms for corrosion and metal release have not been fully understood. This study aims to examine the characteristics and evaluate the corrosion potential of blended water in X city DWDS using four indices of Langelier saturation index (LSI), Ryznar stability index (RSI), Puckorius scaling index (PSI), and calcium carbonate precipitation potential (CCPP). Physical and chemical analysis showed that the values of pH, total dissolved solids (TDS), sulfate (SO42−), and chloride (Cl−) in blended water were always at acceptable levels, while some free residual chlorine concentrations fell outside the regulatory standards (≥ 0.05 mg/L) with the minimum of 0.01 mg/L. Most parameters except pH varied in large ranges with maximum to minimum ratios (MMRs) over 2.25. The mean values of the LSI, RSI, PSI, and CCPP indices were − 0.44, 8.65, 8.79, and − 1.95 mg/L CaCO3, respectively, indicating that the blended water was slightly corrosive. For the three zones, Z2 had the highest mean levels of TDS (320.84 mg/L), alkalinity (188.70 mg/L CaCO3), SO42− (13.69 mg/L), Cl− (36.37 mg/L), calcium hardness (Ca2+) (28.99 mg/L), and magnesium hardness (Mg2+) (15.22 mg/L) and the lowest mean level of dissolved oxygen (DO) (6.72 mg/L). Thus, the corrosion potential in Z2 was the lowest with the LSI, RSI, PSI, and CCPP values of − 0.17, 8.11, 8.08, and 2.87 mg/L CaCO3, respectively. During a year, the corrosion in blended water was more serious in winter with the LSI, RSI, PSI, and CCPP indices of − 0.79, 9.25, 9.37, − 7.54 mg/L CaCO3, respectively. The water corrosivity reached the minimum level in summer (LSI − 0.12, RSI 8.05, PSI 8.03, and CCPP 5.22 mg/L CaCO3) owing to the decrease of DO concentrations and the increase of temperature and groundwater supplies with higher alkalinity. During rainy season, the concentrations of TDS, alkalinity, SO42−, Cl−, Ca2+, and Mg2+ in blended water were reduced by 41.05%, 40.48%, 35.83%, 47.48%, 23.47%, and 55.73%, respectively, resulting in the increase of water corrosivity. More decreases of water parameters were recorded in Z2 (TDS, 221.80 mg/L; alkalinity, 139.50 mg/L CaCO3; SO42−, 9.97 mg/L; Cl−, 13.74 mg/L; Ca2+, 7.10 mg/L; and Mg2+, 11.37 mg/L), because most groundwater from No. 5 WTP was pumped paretic water with more variations of water quality by rainfall. Moreover, it was suggested that Mg2+ should be considered in the corrosion indices, and the corrosion tendency of blended water could be reduced by adjusting the levels of pH, alkalinity, Ca2+, and Mg2+. The results of this research may pave the way for several opportunities to improve the management and corrosion prevention of blended water.
- Open Access
- 5 February 2018
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 22 (8) , 2747-2754
Using DFP Algorithm for Nodal Demand Estimation of Water Distribution Networks
- 5 February 2018
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 22 (8) , 2747-2754
Open AccessUsing DFP Algorithm for Nodal Demand Estimation of Water Distribution Networks
- 31 January 2018
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 26 (3) , 577-588
Development of a software tool for teaching real‐time state simulation of water distribution networks
An educational software tool was developed for teaching the real‐time state simulation of water distribution networks (WDNs) to municipal engineering students. The weighted‐least‐square model and Davidon–Fletcher–Powell (DFP) algorithm were used to calculate the state variable values with real‐time measurements. The software tool was composed of three modules, including network loading, state simulation, and data management. The program and the relevant graphical user interface were coded using Delphi 7.0. The performance of the software tool was proved to be effective in teaching and learning by two evaluation approaches. Moreover, the positive results also encouraged software developers and lecturers to produce or at least use computer‐aided tools for educational purposes.
- 31 January 2018
- Published by Wiley in Computer Applications in Engineering Education
- Vol. 26 (3) , 577-588
Development of a software tool for teaching real‐time state simulation of water distribution networks
An educational software tool was developed for teaching the real‐time state simulation of water distribution networks (WDNs) to municipal engineering students. The weighted‐least‐square model and Davidon–Fletcher–Powell (DFP) algorithm were used to calculate the state variable values with real‐time measurements. The software tool was composed of three modules, including network loading, state simulation, and data management. The program and the relevant graphical user interface were coded using Delphi 7.0. The performance of the software tool was proved to be effective in teaching and learning by two evaluation approaches. Moreover, the positive results also encouraged software developers and lecturers to produce or at least use computer‐aided tools for educational purposes.
- 18 September 2017
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 52 (14) , 1322-1329
Health risk assessment of arsenic from blended water in distribution systems
In a water distribution system with different sources, water blending occurs, causing specific variations of the arsenic level. This study was undertaken to investigate the concentration and cancer risk of arsenic in blended water in Xi'an city. A total of 672 tap water samples were collected from eight sampling points in the blending zones for arsenic determination. The risk was evaluated through oral ingestion and dermal absorption, separately for males and females, as well as with respect to seasons and blending zones. Although the arsenic concentrations always fulfilled the requirements of the World Health Organization (WHO) (≤10 μg L−1), the total cancer risk value was higher than the general guidance risk value of 1.00 × 10−6. In the blending zone of the Qujiang and No.3 WTPs (Z2), the total cancer risk value was over 1.00 × 10−5, indicating that public health would be affected to some extent. More than 99% of the total cancer risk was from oral ingestion, and dermal absorption had a little contribution. With higher exposure duration and lower body weight, women had a higher cancer risk. In addition, due to several influential factors, the total cancer risk in the four blending zones reached the maximum in different seasons. The sensitivity analysis by the tornado chart proved that body weight, arsenic concentration and ingestion rate significantly contributed to cancer risk. This study suggests the regular monitoring of water blending zones for improving risk management.
- 18 September 2017
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 52 (14) , 1322-1329
Health risk assessment of arsenic from blended water in distribution systems
In a water distribution system with different sources, water blending occurs, causing specific variations of the arsenic level. This study was undertaken to investigate the concentration and cancer risk of arsenic in blended water in Xi'an city. A total of 672 tap water samples were collected from eight sampling points in the blending zones for arsenic determination. The risk was evaluated through oral ingestion and dermal absorption, separately for males and females, as well as with respect to seasons and blending zones. Although the arsenic concentrations always fulfilled the requirements of the World Health Organization (WHO) (≤10 μg L−1), the total cancer risk value was higher than the general guidance risk value of 1.00 × 10−6. In the blending zone of the Qujiang and No.3 WTPs (Z2), the total cancer risk value was over 1.00 × 10−5, indicating that public health would be affected to some extent. More than 99% of the total cancer risk was from oral ingestion, and dermal absorption had a little contribution. With higher exposure duration and lower body weight, women had a higher cancer risk. In addition, due to several influential factors, the total cancer risk in the four blending zones reached the maximum in different seasons. The sensitivity analysis by the tornado chart proved that body weight, arsenic concentration and ingestion rate significantly contributed to cancer risk. This study suggests the regular monitoring of water blending zones for improving risk management.