Martín Rodríguez-Vázquez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martín Rodríguez-Vázquez has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Alfredo Aranda-Arizmendi
Facultad de Ciencias Químicas e Ingeniería (FCQeI), Universidad Autónoma del Estado de Morelos, Av. Universidad 1001, Cuernavaca 62210, Morelos, Mexico
1 shared publication - Arturo Abúndez-Pliego
Tecnológico Nacional de México / Centro Nacional de Investigación y Desarrollo Tecnológico (CENIDET). Int. Internado Palmira, Cuernavaca, Morelos, México. C.P. 62490
1 shared publication - Carlos Miguel Jiménez Xaman
Corporación Mexicana de Investigación en Materiales S.A. de C.V. (COMIMSA), Ciencia y Tecnología 790, Col. Saltillo 400, Saltillo 25290, Coahuila, Mexico
1 shared publication - Jorge Colín
Departamento de Ingeniería Mecánica, Tecnológico Nacional de México/CENIDET, Cuernavaca 62490, Morelos, Mexico
1 shared publication - Jorge Yusef Colín-Castillo
Universidad Tecnológica Emiliano Zapata, Avenida Universidad Tecnológica 1 Palo Escrito, Emiliano Zapata 62765, Mexico
1 shared publication - Julio Vergara-Vazquez
Centro Nacional de Investigación y Desarrollo Tecnológico
1 shared publication
Latest Publications
- 18 September 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 260
Online algebraic identification–based trial-weight-free modal balancing of asymmetric rotor–bearing systems
- 18 September 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 260
Online algebraic identification–based trial-weight-free modal balancing of asymmetric rotor–bearing systems
- Open Access
Parametric Study of the Ground-Air Heat Exchanger (GAHE): Effect of Burial Depth and Insulation Length
A parametric study of a ground-to-air heat exchanger (GAHE) using numerical models based on computational fluid dynamics with the finite volume method to evaluate the thermal potential of GAHE is presented. After the validation of the numerical code developed with published experimental data, it is proceeded to the study of the geometric parameters to define those that have the greatest impact on the application potential of GAHE. Climatological variables such as relative humidity, air flow velocity, and inlet air temperature are analyzed, as well as the increase in the thermal conductivity of the soil due to its humidity content. In addition, a study of the optimal installation depth as well as the length of the thermal insulation in the outlet pipe of the GAHE is presented. The results reveal that there is a higher heat exchange potential in the GAHE for an optimal burial depth of 4 m and a length of pipe of 15 m, 30% soil moisture content for heating and 32% for cooling, and a pipe diameter of 0.15 m. The use of thermal insulating is recommended only for the last 2 m of length in the outlet pipe of the GAHE.
Open AccessParametric Study of the Ground-Air Heat Exchanger (GAHE): Effect of Burial Depth and Insulation Length
A parametric study of a ground-to-air heat exchanger (GAHE) using numerical models based on computational fluid dynamics with the finite volume method to evaluate the thermal potential of GAHE is presented. After the validation of the numerical code developed with published experimental data, it is proceeded to the study of the geometric parameters to define those that have the greatest impact on the application potential of GAHE. Climatological variables such as relative humidity, air flow velocity, and inlet air temperature are analyzed, as well as the increase in the thermal conductivity of the soil due to its humidity content. In addition, a study of the optimal installation depth as well as the length of the thermal insulation in the outlet pipe of the GAHE is presented. The results reveal that there is a higher heat exchange potential in the GAHE for an optimal burial depth of 4 m and a length of pipe of 15 m, 30% soil moisture content for heating and 32% for cooling, and a pipe diameter of 0.15 m. The use of thermal insulating is recommended only for the last 2 m of length in the outlet pipe of the GAHE.