MYMinghang Yu

Minghang Yu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Minghang Yu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Danying Chen

    Institute of Infectious Diseases, Beijing Ditan Hospital, Capital Medical University

    1 shared publication
  • Pu Liang

    Beijing Key Laboratory of Emerging Infectious Diseases , Institute of Infectious Diseases, Beijing Ditan Hospital, Capital Medical University , Beijing , P.R. China

    1 shared publication
  • Ronghua Jin

    Beijing Ditan Hospital, Capital Medical University

    1 shared publication
  • Rui Li

    Beijing Key Laboratory of Emerging Infectious Diseases , Institute of Infectious Diseases, Beijing Ditan Hospital, Capital Medical University , Beijing , P.R. China

    1 shared publication
  • Rui Song

    National Center for Infectious Diseases, Beijing Ditan Hospital, Capital Medical University , Beijing , P.R. China

    1 shared publication
  • Xi Wang

    National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, Beijing Ditan Hospital, Capital Medical University, Beijing, China

    1 shared publication

Latest Publications

  • Evaluation of a high-sensitivity SARS-CoV-2 antigen test on the fully automated light-initiated chemiluminescent immunoassay platform

    by Minghang Yu, Danying Chen, Xiaomeng Tang, Yuanyuan Zhang, Pu Liang, Yang Xiong, Rui Li, Rui Song, Xiaoyou Chen, Xuesen Zhao, et al.

    Objectives: To describe a high-sensitivity SARS-CoV-2 antigen test that is based on the fully automated light-initiated chemiluminescent immunoassay (LiCA®), and to validate its analytical characteristics and clinical agreement on detecting SARS-CoV-2 infection against the reference molecular test. Methods: Analytical performance was validated and detection limits were determined using different types of nucleocapsid protein samples. 798-pair anterior nasal swab specimens were collected from hospitalized patients and asymptomatic screening individuals. Agreement between LiCA® antigen and real-time reverse transcription polymerase chain reaction (rRT-PCR) was evaluated. Results: Repeatability and within-lab precision were 1.6–2.3%. The C5∼C95 interval was −5.1–4.6% away from C50. Detection limits in average (SD) were 325 (±141) U/mL on the national reference panel, 0.07 (±0.04) TCID50/mL on active viral cultures, 0.27 (±0.09) pg/mL on recombinant nucleocapsid proteins and 1.07 (±1.01) TCID50/mL on inactivated viral suspensions, respectively. LiCA detected a median of 374-fold (IQR 137–643) lower levels of the viral antigen than comparative rapid tests. As reference to the rRT-PCR method, overall sensitivity and specificity were determined to be 97.5% (91.4–99.7%) and 99.9% (99.2–100%), respectively. Total agreement between both methods was 99.6% (98.7–99.9%) with Cohen’s kappa 0.98 (0.96–1). A positive detection rate of 100% (95.4–100%) was obtained as Ct≤37.8. Conclusions: The LiCA® system provides an exceptionally high-sensitivity and fully automated platform for the detection of the SARS-CoV-2 antigen in nasal swabs. The assay may have high potential use for large-scale population screening and surveillance of COVID-19 as an alternative to the rRT-PCR test.