Szu-Chi Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Szu-Chi Huang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Po-Lei Lee
Department of Electrical Engineering, National Central University, Taoyuan 32001, Taiwan
5 shared publications - Kuo-Kai Shyu
Department of Electrical Engineering, National Central University, Taoyuan 32001, Taiwan
4 shared publications - Lung-Hao Lee
Institute of Artificial Intelligence Innovation, National Yang Ming Chiao Tung University, Hsinchu, Taiwan
3 shared publications - Chao-Jen Huang
Department of Electrical Engineering, National Central University, Taoyuan 32001, Taiwan
1 shared publication Chia-Yi Tseng
Chung Yuan Christian University
1 shared publicationChih-Yu Tseng
National Central University
1 shared publication
Latest Publications
- Open Access
- 8 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (2) , 164
A High-Frequency Temporal-Interference Alternative Current Stimulation Device Using Pulse Amplitude Modulation with Push–Pull Current Sources
This study proposes a high-frequency Pulse Amplitude-Modulation Temporal-Interference (PAM-TI) current stimulation device, which utilizes two sets of Amplitude-modulated transcranial alternating current stimulation (AM-tACS): one AM frequency at f0 (where f0 = 2 kHz) (source 1) and the other AM frequency at f1 = f0 + f (where f1 = 2.01 kHz) (source 2), to generate a f (where f = 10 Hz) envelope modulated at a fc (where fc = 100 kHz) high carrier frequency. The high carrier frequency reduces body impedance and conserves more stimulation power, allowing it to penetrate the skin and reach the subcutaneous region. The proposed PAM-TI technique elevates the two current sources to a 100 kHz carrier frequency. Instead of the challenges associated with generating high-frequency stimulation currents using an MCU and DAC, the proposed PAM-TI stimulation device achieves this by simply utilizing a pair of complementary pulse-width modulations (PWMs). The push–pull technique is employed to balance the charging currents between the anode and cathode, synchronizing the current timing of Source 1 and Source 2 under the fc modulation condition. To minimize signal attenuation, the PAM circuit is integrated directly into the electrode, ensuring the high-frequency signal is generated close to the body and preventing degradation from long wires. Additionally, a dry pin-type spring-loaded electrode is used to reduce interference caused by hair when placed on the head. The device’s validity and current directionality were verified using a scalp tissue-mimicking phantom composed of agar and saline.- 8 February 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (2) , 164
Open AccessA High-Frequency Temporal-Interference Alternative Current Stimulation Device Using Pulse Amplitude Modulation with Push–Pull Current Sources
This study proposes a high-frequency Pulse Amplitude-Modulation Temporal-Interference (PAM-TI) current stimulation device, which utilizes two sets of Amplitude-modulated transcranial alternating current stimulation (AM-tACS): one AM frequency at f0 (where f0 = 2 kHz) (source 1) and the other AM frequency at f1 = f0 + f (where f1 = 2.01 kHz) (source 2), to generate a f (where f = 10 Hz) envelope modulated at a fc (where fc = 100 kHz) high carrier frequency. The high carrier frequency reduces body impedance and conserves more stimulation power, allowing it to penetrate the skin and reach the subcutaneous region. The proposed PAM-TI technique elevates the two current sources to a 100 kHz carrier frequency. Instead of the challenges associated with generating high-frequency stimulation currents using an MCU and DAC, the proposed PAM-TI stimulation device achieves this by simply utilizing a pair of complementary pulse-width modulations (PWMs). The push–pull technique is employed to balance the charging currents between the anode and cathode, synchronizing the current timing of Source 1 and Source 2 under the fc modulation condition. To minimize signal attenuation, the PAM circuit is integrated directly into the electrode, ensuring the high-frequency signal is generated close to the body and preventing degradation from long wires. Additionally, a dry pin-type spring-loaded electrode is used to reduce interference caused by hair when placed on the head. The device’s validity and current directionality were verified using a scalp tissue-mimicking phantom composed of agar and saline. - Open Access
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 139457-139465
Common Spatial Pattern and Riemannian Manifold-Based Real-Time Multiclass Motor Imagery EEG Classification
Several motor imagery classification methods have been developed and achieve higher accuracy. Machine learning (ML) based algorithms utilizing manually designed features often encounter robustness issues, leading to diminished accuracy. While deep learning (DL) based algorithms exhibit promising accuracy, their extensive computational requirements present challenges in implementing them on portable devices, thereby restricting their practical applications. In this paper, we improve the ML-based algorithm’s feature robustness problems by combining common spatial patterns with Riemannian tangent space mapping, enhancing the algorithm’s feature quality. Furthermore, we introduce a method that utilizes the distance between data points and the SVM hyperplane to compute category scores, thereby enhancing classifier performance. Our experiment uses the BCI Competition IV 2A, BCI Competition III 3A, and a self-recorded dataset for subject-specific experiments to validate the algorithm’s classification performance. Experimental results show that the proposed algorithm achieves the best classification performance, with an accuracy of 78.55%, 83.33%, and 57.44% for BCI Competition IV 2A, BCI Competition III 3A, and the self-recorded dataset. Additionally, to assess the practicality of a real-time portable application, we implemented the proposed algorithm on Raspberry Pi and Jetson Nano, measuring their computation time and peak memory usage. The results demonstrate that our algorithm necessitates only 0.08 to 0.3 seconds of computation time and employs a mere 15MB of memory.
- 7 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 139457-139465
Open AccessCommon Spatial Pattern and Riemannian Manifold-Based Real-Time Multiclass Motor Imagery EEG Classification
Several motor imagery classification methods have been developed and achieve higher accuracy. Machine learning (ML) based algorithms utilizing manually designed features often encounter robustness issues, leading to diminished accuracy. While deep learning (DL) based algorithms exhibit promising accuracy, their extensive computational requirements present challenges in implementing them on portable devices, thereby restricting their practical applications. In this paper, we improve the ML-based algorithm’s feature robustness problems by combining common spatial patterns with Riemannian tangent space mapping, enhancing the algorithm’s feature quality. Furthermore, we introduce a method that utilizes the distance between data points and the SVM hyperplane to compute category scores, thereby enhancing classifier performance. Our experiment uses the BCI Competition IV 2A, BCI Competition III 3A, and a self-recorded dataset for subject-specific experiments to validate the algorithm’s classification performance. Experimental results show that the proposed algorithm achieves the best classification performance, with an accuracy of 78.55%, 83.33%, and 57.44% for BCI Competition IV 2A, BCI Competition III 3A, and the self-recorded dataset. Additionally, to assess the practicality of a real-time portable application, we implemented the proposed algorithm on Raspberry Pi and Jetson Nano, measuring their computation time and peak memory usage. The results demonstrate that our algorithm necessitates only 0.08 to 0.3 seconds of computation time and employs a mere 15MB of memory.
- Open Access
- 18 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 49172-49182
Less Parameterization Inception-Based End to End CNN Model for EEG Seizure Detection
Many deep-learning-based seizure detection algorithms have achieved good classification, which usually outperformed traditional machine-learning-based algorithms. However, the hand-engineered features increase the computational complexity and potentially have an ineffectiveness problem for the category. Therefore, this paper proposes a novel end-to-end deep-learning model comprising an inception module and a residual module to analyze the multi-scales of original EEG signals and realize seizure detection without feature extraction. Experiments were conducted and evaluated on the Bonn dataset and the CHB-MIT dataset. In the subject-dependent experiments, our model achieved an average F1-score of 69.34% on the CHB-MIT dataset. In subject-independent experiments, our method achieved an average accuracy of 99.04% on the Bonn dataset and an average F1-score of 37.31% on the CHB-MIT dataset. A series of analyses confirmed that our proposed model has better classification performance and lower computational complexity than existing end-to-end seizure detection models.
- 18 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 49172-49182
Open AccessLess Parameterization Inception-Based End to End CNN Model for EEG Seizure Detection
Many deep-learning-based seizure detection algorithms have achieved good classification, which usually outperformed traditional machine-learning-based algorithms. However, the hand-engineered features increase the computational complexity and potentially have an ineffectiveness problem for the category. Therefore, this paper proposes a novel end-to-end deep-learning model comprising an inception module and a residual module to analyze the multi-scales of original EEG signals and realize seizure detection without feature extraction. Experiments were conducted and evaluated on the Bonn dataset and the CHB-MIT dataset. In the subject-dependent experiments, our model achieved an average F1-score of 69.34% on the CHB-MIT dataset. In subject-independent experiments, our method achieved an average accuracy of 99.04% on the Bonn dataset and an average F1-score of 37.31% on the CHB-MIT dataset. A series of analyses confirmed that our proposed model has better classification performance and lower computational complexity than existing end-to-end seizure detection models.
- Open Access
- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 5990-5999
A Low Complexity Estimation Method of Entropy for Real-Time Seizure Detection
In recent years, many studies have proposed epilepsy detection algorithms, but most of them require high computing resources and a large amount of memory, which are difficult to implement in wearable devices. This paper proposes an epilepsy detection algorithm that uses a small number of features to reduce the memory requirements of the algorithm. During feature extraction, this paper proposes an entropy estimation method that uses bitwise operations instead of logarithmic operations to reduce the algorithm’s demand for computing resources. The experimental results show that the computing time can be reduced by about 81.58%. The epilepsy detection algorithm in this paper is implemented in an ultra-low power embedded system and performs 7 classification tasks in the Bonn data set to verify the performance of the algorithm. The average classification performance is: Accuracy (97.13%), Specificity (97.57%) and Sensitivity (98.42%). Compared with previous studies, the algorithm of this paper has comparable classification performance, but the proposed algorithm only needs 0.23 seconds from feature extraction to classification result, to the best of our knowledge, which is the epilepsy detection algorithm with the least computing time currently applied to wearable devices.
- 16 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 5990-5999
Open AccessA Low Complexity Estimation Method of Entropy for Real-Time Seizure Detection
In recent years, many studies have proposed epilepsy detection algorithms, but most of them require high computing resources and a large amount of memory, which are difficult to implement in wearable devices. This paper proposes an epilepsy detection algorithm that uses a small number of features to reduce the memory requirements of the algorithm. During feature extraction, this paper proposes an entropy estimation method that uses bitwise operations instead of logarithmic operations to reduce the algorithm’s demand for computing resources. The experimental results show that the computing time can be reduced by about 81.58%. The epilepsy detection algorithm in this paper is implemented in an ultra-low power embedded system and performs 7 classification tasks in the Bonn data set to verify the performance of the algorithm. The average classification performance is: Accuracy (97.13%), Specificity (97.57%) and Sensitivity (98.42%). Compared with previous studies, the algorithm of this paper has comparable classification performance, but the proposed algorithm only needs 0.23 seconds from feature extraction to classification result, to the best of our knowledge, which is the epilepsy detection algorithm with the least computing time currently applied to wearable devices.