Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zeynep Ozkurt Kayahan has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Evaluation of Tooth Type and Pulp Chamber Depth on the Accuracy of Endocrown Scans Acquired Using Various Intraoral Scanners

    by Selen Erkul, Zeynep Ozkurt‐Kayahan, Yunus Emre Özden, Mehmet Baybora Kayahan

    Objective: To evaluate the effects of pulp chamber depth, tooth type, and intraoral scanner (IOS) on the accuracy of endocrown digital impressions. Materials and Methods: Standardized endocrown preparations with 2 and 5 mm pulp chamber depths were performed on molar and premolar typodonts. Digital impressions were obtained using three IOSs (Dexis, iTero, and 3Shape). Reference scans were acquired using a laboratory scanner. Accuracy was assessed following best‐fit alignment. Cavity base and axial regions were separately evaluated. Data were analyzed using Kruskal–Wallis and Dunn post hoc tests ( α = 0.05). Results: Pulp chamber depth, tooth type, and IOS significantly affected scanning accuracy ( p < 0.05). Increasing cavity depth increased deviations at cavity base while reducing deviations at axial region. Premolar preparations with 5 mm depth exhibited the highest cavity base deviations (99.5–107.2 μm). At axial region, iTero demonstrated the lowest deviations (28.2 μm) in 5 mm depth molar preparations. Dexis and iTero showed comparable performance at cavity base. Conclusions: Effect of cavity depth was region‐dependent, negatively affecting cavity base while improving accuracy at axial region. Molar preparations demonstrated superior cavity base trueness, whereas premolar preparations exhibited better axial region trueness. Deep premolar preparations represented the most challenging condition for accurate digital acquisition.

  • Effect of varying intraoral scanner tip size, tooth location and preparation design on the marginal and internal fit of 3D-printed zirconia crowns

    by Büşra Betül Öztürk, Yunus Emre Özden, Zeynep Özkurt-Kayahan

    The aim of this research was to evaluate the effect of different size of intraoral scanner tips, tooth location, and preparation design on the marginal and internal fit of 3D-printed zirconia crowns. A total of 120 zirconia crowns were designed and fabricated using a stereolithography-based additive manufacturing workflow; according to standard tessellation language (STL) data obtained with three tip sizes of an intraoral scanner, 2 tooth locations (maxillary central incisor and canine), and 2 preparation designs (standard and rounded) (n = 10). Marginal and internal fit of the crowns were evaluated using a three-dimensional digital measurement approach. STL files were analyzed in 3D analysis software (Geomagic Control X; 3D Systems, Rock Hill, SC, USA) to calculate root-mean-square (RMS) values within the selected marginal and internal regions following superimposition. Data were analyzed using three-way ANOVA and post hoc Tukey tests (α = 0.05). Scanner tip size had a significant effect across all regions (P = 0.013), with the small tip producing significantly higher discrepancies. Canines showed larger marginal, axial, and incisal gaps than central incisors (P = 0.025). Rounded preparation designs demonstrated significantly lower marginal gap values compared with standard preparations (P = 0.001). The marginal and internal fit of additively manufactured zirconia crowns is affected by intraoral scanner tip size, tooth location, and preparation design. Careful selection of scanner tip size and preparation geometry may improve the accuracy of digitally fabricated zirconia restorations.

  • Open Access

    Impact of PVM/MA Copolymer on Dentin Bond Durability

    by Fusun Ozer, Frances Park, Batu Can Yaman, Zeynep Ozkurt-Kayahan, Francis Mante, Markus Blatz

    This study investigated the effect of Polymethyl vinyl ether-co-maleic anhydride (PVM/MA) copolymer incorporation and aging with thermocycling on the shear bond strength (SBS) of an etch-and-rinse adhesive (Adper Single Bond Plus-ASB) and two different self-etch adhesive systems (Clearfil SE Bond-CSE and Fluorobond II-FLB) to dentin. Adhesive systems were applied to 240 dentin sections randomly selected from the occlusal surfaces of 60 extracted molar teeth. The test groups were as follows (n=20): (G1) Pure Clearfil SE (CSE) Bond; (G2) CSE with copolymer (50 mg/ml PVM/MA); (G3) Pure FL II Bond (FLB); (G4) FLB with copolymer (50 mg/ml PVM/MA); (G5) Pure Adper Single Bond (ASB); and (G6) ASB with copolymer (50 mg/ml PVM/MA). A resin composite (Clearfil Majesty Posterior) was applied to the dentin surfaces and light-cured. Half of the specimens from each group were tested immediately after preparation (IM) and the other half was tested after exposure to 20,000 thermal cycles (TC; 5-55 °C). SBS values were measured at a crosshead speed of 0.5 mm/min. Data were analyzed with ANOVA and Tukey's HSD. The PVM/MA copolymer incorporation improved the performance of CSE in the IM group and ASB in the TC group, however, it showed no influence in the other adhesive groups. The self-etch adhesive CSE with the PVM/MA copolymer showed the highest bond strength to dentin surfaces in the IM group (22.0±1.7 MPa). However, copolymer corporation did not increase bonding performance of Fluor containing bonding agent FLB. Thermocycling of test specimens significantly decreased bond strengths in all test groups except for ASB resin adhesive with PVM/MA copolymer. Incorporating PVM/MA into ethanol-based, hydrophilic all-in-one bonding agents may offer a valuable strategy to improve the long-term stability of adhesive systems.

  • Open Access

    Influence of Thermal Aging on the Marginal/Internal Fit of Incisor Veneered and Monolithic Zirconia Crowns

    by Zeynep Özkurt‐Kayahan, Yunus Emre Özden, İrem Çelikyürek Karabağlı, Özgün Yusuf Özyılmaz, Fusun Ozer, Markus B. Blatz

    Objectives: The aim of the study was to evaluate and compare the effect of thermal aging on the marginal and internal adaptation of veneered and monolithic zirconia (MZ) crowns. Materials and Methods: A maxillary central incisor abutment was digitally designed, fabricated using resin, and scanned for crown design. MZ (IPS e.max ZirCAD Prime Esthetic) and veneered zirconia (VZ; coping: Everest, KaVo; layering: IPS e.max Ceram) crowns were fabricated ( n = 10). STL files were analyzed in Geomagic Design X to calculate root mean square (RMS) values within the selected marginal and internal regions before and after 10,000, 30,000, and 50,000 thermal cycles with superimposition. Data were analyzed using Shapiro–Wilk and Mann–Whitney U tests. The comparison of thermal aging treatments was evaluated using the Friedman and post hoc Wilcoxon signed‐rank tests ( p < 0.05). Results: Significant differences were found between MZ and VZ crowns ( p < 0.05). In the MZ group, marginal gaps increased from 104 μm (T0) to 115 μm (T3), and internal gaps from 122 μm (T0) to 146 μm (T3). In the VZ group, marginal gaps increased from 82 μm (T0) to 128 μm (T3) and internal gaps from 136 μm (T0) to 204 μm (T3). VZ crowns showed higher dimensional changes than MZ crowns. Conclusions: Thermal cycling significantly affected the fit of zirconia crowns. VZ crowns exhibited greater dimensional changes after 30,000 and 50,000 thermal cycles, while MZ crowns maintained superior marginal fit during the same periods. Clinical Significance: This study highlights the influence of thermal aging on the marginal and internal adaptation of veneered and MZ crowns. VZ may be more susceptible to marginal or internal discrepancies after thermal aging, when compared with the MZ.

  • Impact of convergence angle of tooth preparation on the fracture resistance of incisor monolithic zirconia crowns

    by Zeynep Ozkurt‐Kayahan, Fusun Ozer, Irem Celikyurek Karabagli, Ender Kazazoglu, Markus B. Blatz

    Purpose: To evaluate the effect of convergence angles on the fracture resistance of monolithic zirconia crowns in maxillary central incisors.Materials and Methods: A maxillary central incisor preparation was digitally designed with four different angles (0°, 8°, 16°, and 22°). For each group, 10 abutment teeth were manufactured using a 3D printer with photosensitive resin and positioned in a maxillary typodont model for scanning procedures. Anatomically contoured monolithic zirconia crowns were fabricated for each group (n = 10), 40 crowns in total, using the subtractive manufacturing technique. The crowns were cemented onto their respective abutments using a self‐adhesive resin cement. Fracture resistance testing was conducted using a universal testing machine and the fracture load was recorded in Newtons (N). The obtained data were statistically analyzed using one‐way ANOVA for intergroup comparisons, and Tukey HSD post‐hoc test was applied to identify significant differences among groups (p < 0.05).Results: A statistically significant difference was found among the groups, with fracture resistance varying according to the convergence angle (p < 0.05). Crowns with 16° angle exhibited the highest values (2897.57 N), followed by 22° (2425.58 N) and 8° (2095.76 N) groups. The lowest value was found at 0° crowns (1830.3 N).Conclusions: The results indicated that the convergence angle had a significant effect on the fracture resistance of monolithic zirconia crowns. Instead of preparing parallel axial walls (0°) in central incisors, creating a tapered preparation design with different levels (8°, 16°, or 22°) increased the fracture resistance. Specifically, 16° was related to the greatest fracture resistance. However, the absence of thermocycling and fatigue testing limits the simulation of long‐term clinical performance.

  • Open Access

    The effect of cavity depth on accuracy of intraoral scanners in intra-coronal restorations

    by Yunus Emre Özden, Bengü Doğu Kaya, Çağla Akbal, Pınar Yılmaz Atalı, Zeynep Özkurt-Kayahan

    This study aimed to evaluate the effect of cavity depth on the accuracy of intraoral scanners (IOS) in intra-coronal restorations, focusing on trueness and precision as defined by International Organization for Standardization (ISO) 5725 standards. Three intra-coronal cavity designs with depths of 2.5 mm (n = 10), 5 mm (n = 10), and 7.5 mm (n = 10) were fabricated using 3-Dimentional (3D) printed tooth models. Scans (n = 30) were performed using the Trios 3 intraoral scanner, and accuracy was assessed by comparing scanned models to reference models. Trueness was measured as the root mean square (RMS) deviation, and precision was calculated from the interquartile range of average absolute distances. Statistical analyses were conducted using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni correction. The accuracy of the IOS was significantly lower at a cavity depth of 7.5 mm compared to 5 mm and 2.5 mm (p < 0.05). RMS values were highest for the 7.5 mm depth, while the lowest precision was observed at this depth. Cavity depth significantly affects the accuracy of IOS in intra-coronal restorations, with deeper cavities resulting in reduced accuracy. This highlights the importance of considering cavity depth when planning IOS workflows. This study shows that scanning accuracy decreases when the distance between the cavity floor and the cusp tip exceeds 5 mm. Elevating the cavity floor with direct methods may help improve scanning accuracy and enhance restoration outcomes.


  • Open Access

    Influence of Preparation Height on Digital Impression Trueness: A Comparative Study of 2 Intraoral Scanners

    by Yunus Emre Özden, Zeynep Yılmaz, Zeynep Özkurt Kayahan, Ender Kazazoğlu

    Background: This study aims to evaluate the effect of crown preparation height on the trueness of intraoral scanners (IOS) by comparing 2 different scanners at varying preparation heights. Methods: A typodont model was prepared with a chamfer finish line at 2 different crown heights (7 mm and 5 mm). A laboratory scanner (E1, 3Shape, Copenhagen, Denmark) was used to obtain a reference scan. Intraoral scanners, Trios 3 (3Shape, Copenhagen, Denmark) and iTero Element 5D Plus (Align Technologies, San Jose, USA), were used for digital impressions. Ten scans were taken for each preparation height per scanner, resulting in a total of 40 scans. The trueness was assessed using Geomagic Control X software by calculating root mean square (RMS) error values between IOS scans and the reference model. Statistical analysis was performed using IBM SPSS v29. An independent sample t-test was applied (α=0.05). Results: The iTero scanner exhibited significantly lower RMS values (0.040 ± 0.005 mm) compared to the Trios 3 scanner (0.049 ± 0.006 mm, P < .001), indicating higher overall trueness. The Trios 3 scanner showed a significant difference in trueness between 5 mm (0.051 ± 0.005 mm) and 7 mm (0.046 ± 0.006 mm) preparations (P=.043), demonstrating improved trueness with greater preparation height. In contrast, the iTero scanner maintained consistent trueness across both preparation heights (P=.451). Conclusion: The trueness varies depending on the intraoral scanner used. Crown height is a factor that affects trueness depending on the scanner.Cite this article as: Özden YE, Yılmaz Z, Özkurt Kayahan Z, Kazazoğlu E. Influence of preparation height on digital impression trueness: a comparative study of 2 intraoral scanners. Essent Dent. 2025, 4, 0030, doi:10.5152/EssentDent.2025.25030.

  • Open Access

    Evaluation of Accuracy of Intraoral Scanner with Different Inlay Preparation Geometry

    by Bengü Doğu Kaya, Yunus Emre Özden, Zeynep Özkurt Kayahan, Pınar Yılmaz Atalı

    Objective: This in vitro study aimed to assess the accuracy of an intraoral scanner in inlay preparations with different geometry. Methods: The upper second premolar tooth-shaped models were designed and prepared using a 3D printer (Phrozen Mega 8K, Phrozen, Taiwan). Three distinct inlay preparation configurations were utilized, including buccal and palatal wall divergence at 6°, 8°, and 10°. The reference 3D images were acquired through scanning of each model with varying inlay preparation using an extraoral scanner (E1, 3Shape, Denmark). Thirty 3D images (samples) were obtained from each of the three models (n = 10) using an intraoral scanner (Trios 3, 3Shape, Denmark). The samples and reference images were saved in Standard Tessellation Language (STL) and imported into software (Geomagic Control X 2022, 3D Systems Inc., USA). Discrepancies between the reference image and the samples were recorded as root mean square (RMS) and standard deviation (SD). Kruskal Wallis and Mann Whitney U tests, and interquartile range (IQR) were used for statistical analysis with THE significance level p


  • Does Cavity Base Shade of Endocrowns Play a Role in the Accuracy of Intraoral Scans?

    by Idil Ozden, Yunus Emre Ozden, Hesna Sazak Ovecoglu, Zeynep Ozkurt Kayahan, Markus B. Blatz

    Objectives: The aim of the present study was to evaluate the effect of composite resin shades (A1, A2, A3, B1) on the accuracy of scans performed using the Trios 3 (3Shape, Denmark) intraoral scanner.Materials and Methods: An endocrown cavity was prepared on an extracted human molar embedded in a mandibular dentate typodont. Composite resin shades (A1, A2, A3, B1) were sequentially placed in the pulp chamber, light‐cured, and scanned using the Trios 3 intraoral scanner. A high‐precision extraoral scanner (E1, 3Shape, Denmark) provided reference data, and the intraoral scanner acquired test data. The composite resin shades were measured using a spectrophotometer (Easyshade, VITA, Germany) to obtain L*, a*, and b* values. Scanning data were analyzed in Geomagic Design X to calculate root mean square (RMS) values for trueness and interquartile range (IQR) for precision.Results: Significant differences in RMS values were found among shade groups (p < 0.001). The highest value was for B1 (0.0336 ± 0.003), and the lowest for A3 (0.0242 ± 0.002). A1 and A2 showed no significant difference, while all other comparisons were significant. The highest IQR value was observed for B1 (0.0040), indicating reduced precision.Conclusions: The composite resin shade considerably influenced intraoral scanner accuracy. Darker shades are suggested for endocrown cavity bases to optimize digital impressions. Further studies are required to investigate these findings in clinical practice.Clinical Significance: This study highlights the influence of cavity base material shade on intraoral scanner accuracy in endocrown restorations. Darker shades improved scanning accuracy, highlighting the importance of material selection in digital workflows.


  • Open Access

    Effect of Print Orientation and Thermal Aging on the Flexural Strength of Zirconia-Reinforced Three-Dimensional-Printed Restorative Resin Materials

    by Yunus Emre Özden, Bengü Doğu Kaya, Pınar Yılmaz Atalı, Fusun Ozer, Zeynep Ozkurt Kayahan

    This study evaluated the effects of print orientation and thermal aging on the flexural strength (FS) and flexural modulus (FM) of novel permanent three-dimensional (3D)-printed polymethyl methacrylate (PMMA) resins reinforced with nano-zirconia and nano-silica. Bar-shaped specimens (25 × 2 × 2 mm) were fabricated using a digital light processing (DLP) 3D printer (Asiga Max UV, Asiga Inc., Australia) in two orientations (0° and 90°). Specimens underwent three-point bending tests at 24 h and after artificial thermal aging (10,000 and 30,000 cycles) to simulate one and three years of intraoral conditions. Scanning electron microscopy (SEM) was used to analyze fracture patterns. Print orientation did not significantly affect FS or FM (p > 0.05). However, artificial aging significantly reduced FS and FM after 10,000 cycles (p < 0.001), with further deterioration after 30,000 cycles. The micro hybrid resin composite exhibited higher FS than the 3D-printed materials throughout aging. SEM analysis revealed distinct fracture patterns, with 3D-printed resins displaying radial fractures and the micro hybrid composite exhibiting horizontal fractures. These findings indicate that aging plays a more critical role in the long-term mechanical performance of 3D-printed restorative resins than print orientation. This study provides original data on the effects of print orientation and prolonged thermal aging on the mechanical behavior of permanent three-dimensional (3D)-printed dental resins. Furthermore, the comparative evaluation of aging protocols simulating one and three years of intraoral service represents a novel contribution to the existing literature. Further studies are required to optimize the mechanical durability of 3D-printed dental restorations.