Novitasari Novitasari
Novitasari Novitasari has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Abdul Hadi Furqoni
Center for Biomedical Research, National Research and Innovation Agency (BRIN), Jl. Raya Bogor, Km. 46 Cibinong, Bogor, West Java, Indonesia
1 shared publication - Ahmad Yudianto
Forensic Department, Faculty of Medicine, Airlangga University, Surabaya, Indonesia
1 shared publication - Asep Rahmat Hidayat
National Research and Innovation Agency Republic of Indonesia
1 shared publication - Bambang Prasetya
National Standardization Agency of Indonesia (BSN), Gedung Badan Pengkajian Dan Penerapan Teknologi (BPPT), Jl. M.H. Thamrin No. 8, Jakarta 10340, Indonesia
1 shared publication - Biatna Dulbert Tampubolon
Center of Research and Human Resources Development National Standardization Agency of Indonesia, South Tangerang, Indonesia
1 shared publication Desak Putu Oki Lestari
Faculty of Medicine and Health Sciences, Warmadewa University Bali
1 shared publication
Latest Publications
- Open Access
- 1 October 2025
- Published by Innovative Research Publishing in International Journal of Innovative Research and Scientific Studies
- Vol. 8 (7) , 72-93
Evaluation and meta-analysis of HTP testing methods in harm reduction
This paper presents a comprehensive literature review to evaluate and synthesize heated tobacco product (HTP) testing methodologies and quantify differences in aerosol emissions versus conventional cigarettes to inform harmonized, health-relevant standards. The review systematically examines scientific publications, regulatory documents, and industrial reports published over the past decade to assess current practices in the mechanical, chemical, and toxicological evaluation of HTPs A systematic review and meta-analysis following PRISMA searched Scopus/Google Scholar through July 2025, screened studies against predefined inclusion criteria, and extracted analytes, instruments, and outcomes; 26 eligible studies were analyzed using Review Manager and JASP with random-effects modeling (REML). Based on studies, HTP aerosols showed large reductions in harmful and potentially harmful constituents relative to cigarette smoke, frequently exceeding 80–90% for key classes; the pooled effect size indicated an ≈88.18% reduction with moderate heterogeneity, and funnel-plot symmetry suggested low publication bias. HTPs consistently produce lower toxicant emissions than conventional cigarettes. However, cross-study variability in devices, puffing regimens, and collection/analytic methods limits direct comparability, underscoring the need for standardized, validated HTP-specific protocols. The findings recommend that regulators and labs could elaborated to adopt harmonized HTP puffing and aerosol-collection methods based on product used specificity to improve product emission robustness and eventual the risk assessment for consumer protection.
- 1 October 2025
- Published by Innovative Research Publishing in International Journal of Innovative Research and Scientific Studies
- Vol. 8 (7) , 72-93
Open AccessEvaluation and meta-analysis of HTP testing methods in harm reduction
This paper presents a comprehensive literature review to evaluate and synthesize heated tobacco product (HTP) testing methodologies and quantify differences in aerosol emissions versus conventional cigarettes to inform harmonized, health-relevant standards. The review systematically examines scientific publications, regulatory documents, and industrial reports published over the past decade to assess current practices in the mechanical, chemical, and toxicological evaluation of HTPs A systematic review and meta-analysis following PRISMA searched Scopus/Google Scholar through July 2025, screened studies against predefined inclusion criteria, and extracted analytes, instruments, and outcomes; 26 eligible studies were analyzed using Review Manager and JASP with random-effects modeling (REML). Based on studies, HTP aerosols showed large reductions in harmful and potentially harmful constituents relative to cigarette smoke, frequently exceeding 80–90% for key classes; the pooled effect size indicated an ≈88.18% reduction with moderate heterogeneity, and funnel-plot symmetry suggested low publication bias. HTPs consistently produce lower toxicant emissions than conventional cigarettes. However, cross-study variability in devices, puffing regimens, and collection/analytic methods limits direct comparability, underscoring the need for standardized, validated HTP-specific protocols. The findings recommend that regulators and labs could elaborated to adopt harmonized HTP puffing and aerosol-collection methods based on product used specificity to improve product emission robustness and eventual the risk assessment for consumer protection.
- Open Access
- 1 October 2024
- Published by Universitas Gadjah Mada in Indonesian Journal of Chemistry
- Vol. 24 (5) , 1386-1397
Limit Detection of Short Tandem Repeats (STR) Analysis on Touch DNA Samples
Forensic short tandem repeats (STR) profiling on touch DNA samples has emerged as a primary method for human identification. The stability and uniqueness of STR combination from the targeted locus in each individual make it a precision marker for human identification. Touch DNA samples can be found in traces of biological material shed from a person. This work aimed to identify the lowest concentration limit required for generating an interpretable DNA profile and the sensitivity of the STR loci applied. Touch DNA samples were collected from donors who were asked to hold a rope for 5 min. A double swab technique was used to lift the touch samples from the rope. These samples are subjected to DNA extraction and quantification. Two STR amplification cycles, 29 and 34 cycles, were used. DNA concentration greatly influences the success of amplifying the target allele at each STR locus to be interpreted into a complete DNA profile, shown by its allele peak. Touch DNA concentration >0.25 ng can produce a complete DNA profile. LCN method successfully amplified touch DNA with a concentration 0.0625–0.25 ng/µL. Limit detection of touch DNA analysis is 0.25 ng/µL. Low-copy DNA can still be analyzed within 0.0625–0.25 ng/µL.
- 1 October 2024
- Published by Universitas Gadjah Mada in Indonesian Journal of Chemistry
- Vol. 24 (5) , 1386-1397
Open AccessLimit Detection of Short Tandem Repeats (STR) Analysis on Touch DNA Samples
Forensic short tandem repeats (STR) profiling on touch DNA samples has emerged as a primary method for human identification. The stability and uniqueness of STR combination from the targeted locus in each individual make it a precision marker for human identification. Touch DNA samples can be found in traces of biological material shed from a person. This work aimed to identify the lowest concentration limit required for generating an interpretable DNA profile and the sensitivity of the STR loci applied. Touch DNA samples were collected from donors who were asked to hold a rope for 5 min. A double swab technique was used to lift the touch samples from the rope. These samples are subjected to DNA extraction and quantification. Two STR amplification cycles, 29 and 34 cycles, were used. DNA concentration greatly influences the success of amplifying the target allele at each STR locus to be interpreted into a complete DNA profile, shown by its allele peak. Touch DNA concentration >0.25 ng can produce a complete DNA profile. LCN method successfully amplified touch DNA with a concentration 0.0625–0.25 ng/µL. Limit detection of touch DNA analysis is 0.25 ng/µL. Low-copy DNA can still be analyzed within 0.0625–0.25 ng/µL.
- Open Access
- 1 February 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (1) , 1152-1160
Real-time wireless temperature measurement system of infant incubator
The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.
- 1 February 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (1) , 1152-1160
Open AccessReal-time wireless temperature measurement system of infant incubator
The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.
- Open Access
- 14 October 2022
- Published by Fakultas Kedokteran UPN Veteran Jakarta in Jurnal Profesi Medika : Jurnal Kedokteran dan Kesehatan
- Vol. 16 (2)
The Relationship Between Cervical Cancer Severity and miRNA-205 Expression in Bali
Cervical cancer is the one of leading cause of death for women worldwide. It occurs due to infection with the human papilloma virus (HPV) which attacks the cervix in the female reproductive organs. The detecting cervical cancer method is by using pap smears and liquid based cytology (LBC) and vaccinations. However, both methods are limited in detecting cervical cancer quickly and accurately. This study aims to find potential biomarkers that will be used to quickly detect the development of cervical cancer. Large-scale studies have shown that microRNA-205 (miRNA) regulation has a very important role in various types of cancer including cervical cancer. The extraction and synthesis of cDNA from 26 preparations of cervical cancer paraffin blocks were measured by quantitative real time PCR to evaluate the expression of miRNA-205 as a biomarker of cervical cancer in cervical cancer samples. Statistical results showed that there was a significant difference in the expression of miRNA-205 which was relatively higher in cervical cancer patients (p<0.05) miRNA-205. In addition, the increased expression of miRNA-205 is associated with an increase in the severity of cervical cancer. We conclude that miRNA-205 is a potential candidate for cervical cancer molecular biomarker.
- 14 October 2022
- Published by Fakultas Kedokteran UPN Veteran Jakarta in Jurnal Profesi Medika : Jurnal Kedokteran dan Kesehatan
- Vol. 16 (2)
Open AccessThe Relationship Between Cervical Cancer Severity and miRNA-205 Expression in Bali
Cervical cancer is the one of leading cause of death for women worldwide. It occurs due to infection with the human papilloma virus (HPV) which attacks the cervix in the female reproductive organs. The detecting cervical cancer method is by using pap smears and liquid based cytology (LBC) and vaccinations. However, both methods are limited in detecting cervical cancer quickly and accurately. This study aims to find potential biomarkers that will be used to quickly detect the development of cervical cancer. Large-scale studies have shown that microRNA-205 (miRNA) regulation has a very important role in various types of cancer including cervical cancer. The extraction and synthesis of cDNA from 26 preparations of cervical cancer paraffin blocks were measured by quantitative real time PCR to evaluate the expression of miRNA-205 as a biomarker of cervical cancer in cervical cancer samples. Statistical results showed that there was a significant difference in the expression of miRNA-205 which was relatively higher in cervical cancer patients (p<0.05) miRNA-205. In addition, the increased expression of miRNA-205 is associated with an increase in the severity of cervical cancer. We conclude that miRNA-205 is a potential candidate for cervical cancer molecular biomarker.