Yi Gan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yi Gan has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Fujia Sun
School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai, China
2 shared publications- Fujia Sun
University of Shanghai for Science and Technology
2 shared publications - Geng Yang
State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering Zhejiang University Hangzhou China
2 shared publications - Huimin Shen
University of Shanghai for Science and Technology
2 shared publications - Li Gao
University of Shanghai for Science and Technology
2 shared publications Yansong Zhao
School of Mechanical Engineering, University of Shanghai for Science and Technology, Shanghai, China
2 shared publications
Latest Publications
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (3) , 3844-3851
Design and Analysis of a Robotic Dexterous Hand: Combining Linkage Driven and Pneumatic Actuation
This letter introduces a 10-active degree-of-freedom (DoF) robotic dexterous hand incorporating 4 modular fingers and 1 opposable thumb. Each finger (except the middle one) has 2-active-DoF implemented through 1 active flexion-extension (F-E) Proximal Interphalangeal (PIP) joint, 1 passive F-E Distal Interphalangeal (DIP) joint, and 1 active abduction-adduction (A-A) Metacarpophalangeal (MCP) joint. Specifically, the F-E motion of the PIP joint is actuated by a linear motor, and that of the DIP joint is mechanically coupled through a link. In contrast, the MCP joint’s A-A motion is pneumatically actuated due to its lower force requirements. A mathematical model that captures the chamber wall interactions in three consecutive stages (i.e., before contact, contact initiation, and during contact) is established to relate the pneumatic actuation to the finger A-A motion. Additionally, the proposed thumb has 3-active-DoF driven by 3 separate motors, allowing it to perform opposition movements to the other fingers. In the grasp evaluation, our hand successfully reproduces 7 out of 10 Kapandji test and 25 out of 33 grasps defined by the GRASP taxonomy.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (3) , 3844-3851
Design and Analysis of a Robotic Dexterous Hand: Combining Linkage Driven and Pneumatic Actuation
This letter introduces a 10-active degree-of-freedom (DoF) robotic dexterous hand incorporating 4 modular fingers and 1 opposable thumb. Each finger (except the middle one) has 2-active-DoF implemented through 1 active flexion-extension (F-E) Proximal Interphalangeal (PIP) joint, 1 passive F-E Distal Interphalangeal (DIP) joint, and 1 active abduction-adduction (A-A) Metacarpophalangeal (MCP) joint. Specifically, the F-E motion of the PIP joint is actuated by a linear motor, and that of the DIP joint is mechanically coupled through a link. In contrast, the MCP joint’s A-A motion is pneumatically actuated due to its lower force requirements. A mathematical model that captures the chamber wall interactions in three consecutive stages (i.e., before contact, contact initiation, and during contact) is established to relate the pneumatic actuation to the finger A-A motion. Additionally, the proposed thumb has 3-active-DoF driven by 3 separate motors, allowing it to perform opposition movements to the other fingers. In the grasp evaluation, our hand successfully reproduces 7 out of 10 Kapandji test and 25 out of 33 grasps defined by the GRASP taxonomy.
- Open Access
- 10 December 2025
- Published by MDPI AG in Computation
- Vol. 13 (12) , 291
Top-Down Optimization of a Multi-Physics TBS Model via Design-Change Propagation Network for Acoustic Levitation Devices
To address the challenges of interdependent design parameters and reliance on empirical trial-and-error in ultrasonic cell levitation culture devices, this study proposes a top-down design framework integrating multi-physics modeling with complex network analysis. First, acoustic field simulations optimize transducer arrangement and define the cell manipulation field, establishing the Top-level Basic Structure (TBS). A skeleton model of the acoustofluidic coupled field is constructed based on the TBS. Core parameters are then determined by refining the TBS through multi-physics analysis. Second, a 24-node design change propagation network is constructed. Leveraging the TBS model coupled with multi-physics fields, a directed network model analyzes parameter interactions. The HITS algorithm is applied to prioritize the design sequence based on authority and hub scores, resolving parameter conflicts. Experimental validation demonstrates a device acoustic pressure of 1.3 × 104 Pa, stable cell levitation within the focused acoustic field, and a 40% reduction in design cycle time compared to traditional methods. This framework systematically sequences parameters, effectively determines the design order, enhances design efficiency, and significantly reduces dependence on empirical trial-and-error. It provides a novel approach for developing high-throughput organoid culture equipment.
- 10 December 2025
- Published by MDPI AG in Computation
- Vol. 13 (12) , 291
Open AccessTop-Down Optimization of a Multi-Physics TBS Model via Design-Change Propagation Network for Acoustic Levitation Devices
To address the challenges of interdependent design parameters and reliance on empirical trial-and-error in ultrasonic cell levitation culture devices, this study proposes a top-down design framework integrating multi-physics modeling with complex network analysis. First, acoustic field simulations optimize transducer arrangement and define the cell manipulation field, establishing the Top-level Basic Structure (TBS). A skeleton model of the acoustofluidic coupled field is constructed based on the TBS. Core parameters are then determined by refining the TBS through multi-physics analysis. Second, a 24-node design change propagation network is constructed. Leveraging the TBS model coupled with multi-physics fields, a directed network model analyzes parameter interactions. The HITS algorithm is applied to prioritize the design sequence based on authority and hub scores, resolving parameter conflicts. Experimental validation demonstrates a device acoustic pressure of 1.3 × 104 Pa, stable cell levitation within the focused acoustic field, and a 40% reduction in design cycle time compared to traditional methods. This framework systematically sequences parameters, effectively determines the design order, enhances design efficiency, and significantly reduces dependence on empirical trial-and-error. It provides a novel approach for developing high-throughput organoid culture equipment.
- 6 February 2025
- Published by Elsevier in Microchemical Journal
- Vol. 210
Research on the application of image processing technology in monitoring the suspension height of cell cultures
- 6 February 2025
- Published by Elsevier in Microchemical Journal
- Vol. 210
Research on the application of image processing technology in monitoring the suspension height of cell cultures
- Open Access
- 4 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-14
Study on the heating law of thermal effect of HIFU on tissue based on piezoelectric ceramic voltage and vibration frequency
When high-intensity focused ultrasound (HIFU) is used to heat human tissues during surgery, shortening the heating time and increasing the heating rate are crucial for implementing surgery. During operations, the vibration frequencies and voltages that are suitable for piezoelectric ceramics can maximize the heating rate of HIFU. To correctly select the frequency and voltage of piezoelectric ceramics, it is necessary to understand the change law between the frequency and voltage of piezoelectric ceramics and the temperature of the heated tissue. Therefore, this study focuses on the piezoelectric ceramics in the ultrasonic transducer that produces HIFU. By coupling the piezoelectric equation, Helmholtz equation, and biological heat transfer equation of piezoelectric ceramics, the solid mechanical properties of piezoelectric ceramics and the sound field and temperature field produced by its vibration are combined to determine the influence of vibration frequency and voltage on heating time. Results show that the relation between the temperature variation of the tissue, vibration frequency, and voltage of the piezoelectric ceramics can be determined using the Rational Taylor function. The maximum voltage that the piezoelectric ceramics with different frequencies can withstand varies greatly.
- 4 February 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-14
Open AccessStudy on the heating law of thermal effect of HIFU on tissue based on piezoelectric ceramic voltage and vibration frequency
When high-intensity focused ultrasound (HIFU) is used to heat human tissues during surgery, shortening the heating time and increasing the heating rate are crucial for implementing surgery. During operations, the vibration frequencies and voltages that are suitable for piezoelectric ceramics can maximize the heating rate of HIFU. To correctly select the frequency and voltage of piezoelectric ceramics, it is necessary to understand the change law between the frequency and voltage of piezoelectric ceramics and the temperature of the heated tissue. Therefore, this study focuses on the piezoelectric ceramics in the ultrasonic transducer that produces HIFU. By coupling the piezoelectric equation, Helmholtz equation, and biological heat transfer equation of piezoelectric ceramics, the solid mechanical properties of piezoelectric ceramics and the sound field and temperature field produced by its vibration are combined to determine the influence of vibration frequency and voltage on heating time. Results show that the relation between the temperature variation of the tissue, vibration frequency, and voltage of the piezoelectric ceramics can be determined using the Rational Taylor function. The maximum voltage that the piezoelectric ceramics with different frequencies can withstand varies greatly.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 3320-3330
A Magnetic-Inertial Sensing Fusion Information-Driven Digital Twin Approach for the Human Hand
As an important natural medium for human interaction with the external environment, the hand has a high degree of dexterity and complexity, and accurate human hand digital twin models play an important role in the field of medical rehabilitation. In this paper, magnetic-inertial sensing fusion information is used as driving data to build a personalized digital twin model of the human hand. A parametric hand model based on the individual phalange bio-constructive characteristics is established. To derive the personalized individual hand parametric model, the fingertip position detection problem is transformed into a magnetic field inverse problem by using a passive magnetic source as a marker with s tructurized spatial physical field. The magnetic-inertial sensing fusion information helps dimensionality reduction of the higher-order full-posture inversion problem without individual calibration. The derived personalized hand geometry parameters were compared with medical digital photographic markers with an error of [0.38, 2.87] mm. A personalized human hand digital twin platform driven by magnetic-inertial sensing fusion information was developed based on the Matlab Simscape Multibody module. Dynamic twin model driver based on real-time human hand motion detection information was implemented. The sphere grasp experiments show that the relative fitting error (%) according to derived fingertip position for the radius of 50 mm, 60 mm, and 70 mm is 0.14 %, 0.25 %, and 1.08 %, respectively, demonstrating the good performance of the proposed system.
- 11 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (2) , 3320-3330
A Magnetic-Inertial Sensing Fusion Information-Driven Digital Twin Approach for the Human Hand
As an important natural medium for human interaction with the external environment, the hand has a high degree of dexterity and complexity, and accurate human hand digital twin models play an important role in the field of medical rehabilitation. In this paper, magnetic-inertial sensing fusion information is used as driving data to build a personalized digital twin model of the human hand. A parametric hand model based on the individual phalange bio-constructive characteristics is established. To derive the personalized individual hand parametric model, the fingertip position detection problem is transformed into a magnetic field inverse problem by using a passive magnetic source as a marker with s tructurized spatial physical field. The magnetic-inertial sensing fusion information helps dimensionality reduction of the higher-order full-posture inversion problem without individual calibration. The derived personalized hand geometry parameters were compared with medical digital photographic markers with an error of [0.38, 2.87] mm. A personalized human hand digital twin platform driven by magnetic-inertial sensing fusion information was developed based on the Matlab Simscape Multibody module. Dynamic twin model driver based on real-time human hand motion detection information was implemented. The sphere grasp experiments show that the relative fitting error (%) according to derived fingertip position for the radius of 50 mm, 60 mm, and 70 mm is 0.14 %, 0.25 %, and 1.08 %, respectively, demonstrating the good performance of the proposed system.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40581-40594
Optimization Design Method for Ultrasonic Transducers Based on Top Basic Skeleton Method and Sound Pressure Distribution in the Sound Field
Ultrasound is widely used in engineering and biology for applications such as ultrasonic cleaning, cutting, and cancer treatment. Piezoelectric ultrasonic transducers are widely used to generate ultrasonic waves. In the existing transducer design process, no clear and specific intelligent design or manufacturing method has been proposed; therefore, ultrasonic transducers cannot effectively meet the actual requirements. In the industry, top-down intelligent design methods have been widely used and have achieved good results. Therefore, a top-down design method for industrial products can be considered to optimize the design of existing ultrasonic transducers. This study combines a top basic skeleton (TBS) design method based on a top-down design method that was proposed in our previous research with the piezoelectric equation and nonlinear Westervelt equation. In the TBS, the distribution of sound pressure in the sound field is used as a constraint condition to provide a reference for the design of ultrasonic transducers. Considering a focused ultrasound transducer as an example, to ensure that the sound field in the treatment process of high-intensity focused ultrasound meets the treatment requirements of different sound field intensities and focusing depths, an original single-vibrator focused ultrasound transducer is optimized. The experimental results show that the optimization design method proposed in this article is effective, and the focusing depth and sound field intensity of the transducer can be adjusted by modularly replacing parts and controlling the working quantity and excitation of piezoelectric ceramics, thereby achieving the design goal.
- 8 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (24) , 40581-40594
Optimization Design Method for Ultrasonic Transducers Based on Top Basic Skeleton Method and Sound Pressure Distribution in the Sound Field
Ultrasound is widely used in engineering and biology for applications such as ultrasonic cleaning, cutting, and cancer treatment. Piezoelectric ultrasonic transducers are widely used to generate ultrasonic waves. In the existing transducer design process, no clear and specific intelligent design or manufacturing method has been proposed; therefore, ultrasonic transducers cannot effectively meet the actual requirements. In the industry, top-down intelligent design methods have been widely used and have achieved good results. Therefore, a top-down design method for industrial products can be considered to optimize the design of existing ultrasonic transducers. This study combines a top basic skeleton (TBS) design method based on a top-down design method that was proposed in our previous research with the piezoelectric equation and nonlinear Westervelt equation. In the TBS, the distribution of sound pressure in the sound field is used as a constraint condition to provide a reference for the design of ultrasonic transducers. Considering a focused ultrasound transducer as an example, to ensure that the sound field in the treatment process of high-intensity focused ultrasound meets the treatment requirements of different sound field intensities and focusing depths, an original single-vibrator focused ultrasound transducer is optimized. The experimental results show that the optimization design method proposed in this article is effective, and the focusing depth and sound field intensity of the transducer can be adjusted by modularly replacing parts and controlling the working quantity and excitation of piezoelectric ceramics, thereby achieving the design goal.
- 22 November 2023
- Published by Elsevier in Applied Acoustics
- Vol. 216
Study of rib protection devices based on resistant muffler theory for transcostal focused ultrasound therapy
- 22 November 2023
- Published by Elsevier in Applied Acoustics
- Vol. 216
Study of rib protection devices based on resistant muffler theory for transcostal focused ultrasound therapy
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Electromagnetic Actuated Flexible Laser Fiber Steering Monitoring Based on Self-Sensation and Precalibration
In fiber-delivery laser surgery, both accurate actuation and sensation of flexible laser fiber is essential to achieve high precise steering control of laser system in narrow intravital operation space. This paper proposes a self-sensing method for flexible laser fiber steering monitoring based on the electromagnetic coupling actuation principle. Self-sensing of the laser fiber steering is realized by solving an inverse magnetic problem of passive magnetic source localization based on homologous actuation electromagnetic field without involving other detection technologies. To further guarantee high actuation and sensation, Kalman filter algorithm and electromagnetic actuation pre-calibration is applied. A compact proof-of-concept prototype is developed for feasibility demonstration. Systematic sensing experiments were carried out, including single-point static tracking, 1D and 2D dynamic tracking. For 2D dynamic tracking, the relative tracking error in x- and y-axis distributes in [-4.27, 4.13] % and [-3.72, 2.99] %, respectively, with mean tracking error of 0.018 mm.
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-13
Electromagnetic Actuated Flexible Laser Fiber Steering Monitoring Based on Self-Sensation and Precalibration
In fiber-delivery laser surgery, both accurate actuation and sensation of flexible laser fiber is essential to achieve high precise steering control of laser system in narrow intravital operation space. This paper proposes a self-sensing method for flexible laser fiber steering monitoring based on the electromagnetic coupling actuation principle. Self-sensing of the laser fiber steering is realized by solving an inverse magnetic problem of passive magnetic source localization based on homologous actuation electromagnetic field without involving other detection technologies. To further guarantee high actuation and sensation, Kalman filter algorithm and electromagnetic actuation pre-calibration is applied. A compact proof-of-concept prototype is developed for feasibility demonstration. Systematic sensing experiments were carried out, including single-point static tracking, 1D and 2D dynamic tracking. For 2D dynamic tracking, the relative tracking error in x- and y-axis distributes in [-4.27, 4.13] % and [-3.72, 2.99] %, respectively, with mean tracking error of 0.018 mm.
- 12 January 2022
- Published by Springer Nature in Applied Intelligence
- Vol. 52 (9) , 10270-10284
A novel intelligent denoising method of ecg signals based on wavelet adaptive threshold and mathematical morphology
- 12 January 2022
- Published by Springer Nature in Applied Intelligence
- Vol. 52 (9) , 10270-10284
A novel intelligent denoising method of ecg signals based on wavelet adaptive threshold and mathematical morphology