Ahmed G. Rahma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed G. Rahma has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Pierre François
6 shared publications- Abdellah Ghenaim
Laboratory of Mechanics and Environment ICUBE/INSA National Institute of the Applied Sciences Strasbourg France
4 shared publications - Abderahmane Marouf
University of Strasbourg
4 shared publications - Talaat Abdelhamid
Physics and Mathematical Engineering Department, Faculty of Electronic Engineering, Menoufiya University, Menouf, Egypt
4 shared publications Yannick Hoarau
4 shared publicationsAbderahmane Marouf
3 shared publications
Latest Publications
- 9 October 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Numerical simulation of two-phase closed thermosiphon systems for cooling and heat recovery in data centers
Simulation numérique de systèmes à thermosiphon fermés diphasiques pour le refroidissement et la récupération de chaleur dans les data centers: Cette thèse présente une étude numérique des thermosiphons diphasiques fermés (TPCT) pour le refroidissement passif des centres de données. Une analyse multicritères des fluides frigorigènes désigne l'eau comme le plus performant (89/90). Des simulations VOF couplées au modèle de Lee (STAR-CCM+) ont été menées à 1,01325 et 0,2 bar ; un nouveau modèle Densité-Pression du coefficient de relaxation de la condensation atteint des erreurs inférieures à 4,33%. Une étude paramétrique sur quinze configurations montre que le nombre de confinement et la vitesse superficielle de la vapeur gouvernent les transitions de régimes d'écoulement (bouchons, geyser, churn, bulles). Un taux de remplissage élevé stabilise l'écoulement et améliore la conductance thermique. En 3D, Co = 0,2 offre les meilleures performances, avec une conductivité effective supérieure à celle du cuivre au-delà de 10 kW/m², tandis que Co = 0,4 conduit à une défaillance thermique.
- 9 October 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Numerical simulation of two-phase closed thermosiphon systems for cooling and heat recovery in data centers
Simulation numérique de systèmes à thermosiphon fermés diphasiques pour le refroidissement et la récupération de chaleur dans les data centers: Cette thèse présente une étude numérique des thermosiphons diphasiques fermés (TPCT) pour le refroidissement passif des centres de données. Une analyse multicritères des fluides frigorigènes désigne l'eau comme le plus performant (89/90). Des simulations VOF couplées au modèle de Lee (STAR-CCM+) ont été menées à 1,01325 et 0,2 bar ; un nouveau modèle Densité-Pression du coefficient de relaxation de la condensation atteint des erreurs inférieures à 4,33%. Une étude paramétrique sur quinze configurations montre que le nombre de confinement et la vitesse superficielle de la vapeur gouvernent les transitions de régimes d'écoulement (bouchons, geyser, churn, bulles). Un taux de remplissage élevé stabilise l'écoulement et améliore la conductance thermique. En 3D, Co = 0,2 offre les meilleures performances, avec une conductivité effective supérieure à celle du cuivre au-delà de 10 kW/m², tandis que Co = 0,4 conduit à une défaillance thermique.
- Open Access
- 31 August 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 305
Experimental investigation of the optimum operating conditions of a two-phase closed thermosiphon using water at sub-atmospheric pressure
- 31 August 2026
- Published by Elsevier in Applied Thermal Engineering
- Vol. 305
Open AccessExperimental investigation of the optimum operating conditions of a two-phase closed thermosiphon using water at sub-atmospheric pressure
- Open Access
- 3 August 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 35
Experimental and numerical investigation of thermo-fluid performance in a subatmospheric two-phase closed thermosiphon: Effect of filling ratio and input power
- 3 August 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 35
Open AccessExperimental and numerical investigation of thermo-fluid performance in a subatmospheric two-phase closed thermosiphon: Effect of filling ratio and input power
- Open Access
- 2 July 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 35
Thermal performance and flow patterns of confined small-diameter Two-Phase Closed Thermosiphons: A three-dimensional numerical investigation
- 2 July 2026
- Published by Elsevier in International Journal of Thermofluids
- Vol. 35
Open AccessThermal performance and flow patterns of confined small-diameter Two-Phase Closed Thermosiphons: A three-dimensional numerical investigation
- Open Access
- 19 April 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 265
Thermal and flow pattern analysis under confinement and vapor superficial velocity conditions in a two-phase closed thermosiphon: A numerical study
- 19 April 2026
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 265
Open AccessThermal and flow pattern analysis under confinement and vapor superficial velocity conditions in a two-phase closed thermosiphon: A numerical study
- Open Access
- 18 December 2025
- Published by Springer Nature in Journal of Engineering and Applied Science
- Vol. 72 (1) , 254
Two-phase thermosiphon cooling in data centers: a comprehensive review of refrigerants for practical selection
Data centers (DCs) play a crucial role in supporting artificial intelligence (AI), online platforms and cloud services. Currently, there are approximately 5 billion users worldwide, and this number is expected to grow by 5% annually. This surge will result in a substantial increase in energy consumption and will push us to reconsider appropriate energy management strategies. Two-Phase Thermosiphon (TPT) systems provide effective cooling for DCs through the natural circulation driven by gravity and the phase change of refrigerants. This process facilitates efficient heat transfer without the need for moving components, resulting in improved reliability and energy efficiency, which makes them well-suited for medium to high-density power applications. This paper presents a theoretical and practical in-depth review of common refrigerants used in TPT systems and evaluated them in terms of thermal capacity, operating conditions, geometrical design limitations, environmental impact, health and safety considerations, and international regulations. To synthesize the evaluation of the theoretical comparison findings, a decision matrix was developed to assess the overall suitability of selected refrigerants across all criteria. Water ranked highest, achieving an outstanding score of 89 out of 90, followed by methanol, ammonia, and ethanol with 58.5, 56.5, and 56, respectively. Other natural refrigerants such as pentane and 2-methylbutane demonstrated moderate suitability. In contrast, several alternatives received significantly lower scores due to safety concerns or unfavorable environmental characteristics. Based on in-practice comparisons, water exhibits higher thermal conductance, greater heat capacity, and enhanced thermal stability than many refrigerants commonly employed in TPT systems across a range of operating conditions.
- 18 December 2025
- Published by Springer Nature in Journal of Engineering and Applied Science
- Vol. 72 (1) , 254
Open AccessTwo-phase thermosiphon cooling in data centers: a comprehensive review of refrigerants for practical selection
Data centers (DCs) play a crucial role in supporting artificial intelligence (AI), online platforms and cloud services. Currently, there are approximately 5 billion users worldwide, and this number is expected to grow by 5% annually. This surge will result in a substantial increase in energy consumption and will push us to reconsider appropriate energy management strategies. Two-Phase Thermosiphon (TPT) systems provide effective cooling for DCs through the natural circulation driven by gravity and the phase change of refrigerants. This process facilitates efficient heat transfer without the need for moving components, resulting in improved reliability and energy efficiency, which makes them well-suited for medium to high-density power applications. This paper presents a theoretical and practical in-depth review of common refrigerants used in TPT systems and evaluated them in terms of thermal capacity, operating conditions, geometrical design limitations, environmental impact, health and safety considerations, and international regulations. To synthesize the evaluation of the theoretical comparison findings, a decision matrix was developed to assess the overall suitability of selected refrigerants across all criteria. Water ranked highest, achieving an outstanding score of 89 out of 90, followed by methanol, ammonia, and ethanol with 58.5, 56.5, and 56, respectively. Other natural refrigerants such as pentane and 2-methylbutane demonstrated moderate suitability. In contrast, several alternatives received significantly lower scores due to safety concerns or unfavorable environmental characteristics. Based on in-practice comparisons, water exhibits higher thermal conductance, greater heat capacity, and enhanced thermal stability than many refrigerants commonly employed in TPT systems across a range of operating conditions.
- Open Access
- 13 November 2025
- Published by Springer Nature in Discover Applied Sciences
- Vol. 7 (11) , 1367
Hemodynamic characterization of abdominal aortic fusiform aneurysm: insights from computational fluid dynamics simulations
- 13 November 2025
- Published by Springer Nature in Discover Applied Sciences
- Vol. 7 (11) , 1367
Open AccessHemodynamic characterization of abdominal aortic fusiform aneurysm: insights from computational fluid dynamics simulations
- 9 November 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (12)
Numerical Simulations for Calibration Setup for Dynamic Contrast‐Enhanced Ultrasonography Imaging Protocol
This study presents an investigation of an innovative microfluidic flow separator using both numerical and experimental approaches to calibrate contrast‐enhanced ultrasound scanners. Numerical simulations were conducted using Lagrangian particles tracking and passive scalar transport methodologies using the OpenFOAM software. The experimental validation confirmed the accuracy of the numerical simulations, particularly at an imposed total pressure of , showing an excellent agreement in particle distributions. The study emphasizes the computational efficiency and modeling of passive scalar transport, providing valuable understanding into the behavior of scalar quantities in microfluidic systems. An optimized diffusion coefficient value of was identified, showing its critical role in achieving accurate simulation results and optimizing the performance of microfluidic flow separators for contrast‐enhanced ultrasound scanner calibration.
- 9 November 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (12)
Numerical Simulations for Calibration Setup for Dynamic Contrast‐Enhanced Ultrasonography Imaging Protocol
This study presents an investigation of an innovative microfluidic flow separator using both numerical and experimental approaches to calibrate contrast‐enhanced ultrasound scanners. Numerical simulations were conducted using Lagrangian particles tracking and passive scalar transport methodologies using the OpenFOAM software. The experimental validation confirmed the accuracy of the numerical simulations, particularly at an imposed total pressure of , showing an excellent agreement in particle distributions. The study emphasizes the computational efficiency and modeling of passive scalar transport, providing valuable understanding into the behavior of scalar quantities in microfluidic systems. An optimized diffusion coefficient value of was identified, showing its critical role in achieving accurate simulation results and optimizing the performance of microfluidic flow separators for contrast‐enhanced ultrasound scanner calibration.
- 2 December 2023
- Published by Springer Nature
- p. 227-248
The Ability of the CFD Approach to Investigate the Fluid and Wall Hemodynamics of Cerebral Stenosis and Aneurysm
- 2 December 2023
- Published by Springer Nature
- p. 227-248
The Ability of the CFD Approach to Investigate the Fluid and Wall Hemodynamics of Cerebral Stenosis and Aneurysm