Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Akash Gupta has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photoacoustic Gas Sensing Using a Novel Fluidic Microphone Based on Thermal MEMS

    by Akash Gupta, Anant Bhardwaj, Achim Bittner, Alfons Dehé

    Photoacoustic spectroscopy (PAS) is a powerful technique for selective gas detection; however, its performance in non-resonant configurations is fundamentally constrained by the poor low-frequency response of conventional acoustic detectors. Commercial MEMS microphones, although compact and cost effective, exhibit limited infrasound sensitivity, which restricts the development of truly miniaturised and broadband PAS systems. To address this limitation, we present a novel MEMS fluidic microphone (f-mic) that operates on a thermal sensing principle and is explicitly optimised for the infrasound regime. The sensor demonstrates a constant sensitivity of 32 μV/Pa for frequencies below 20 Hz. A detailed analytical model incorporating frequency-dependent effects is developed to identify and investigate the critical design parameters that influence system performance. The overall system exhibits a band-pass frequency response, enabling broadband operation. Based on these insights, a miniaturised photoacoustic cell is fabricated, ensuring efficient optical coupling and f-mic integration. Experimental validation using a CO2-targeted laser system demonstrates a linear response up to 5000 ppm, a sensitivity of 6 nV/ppm, and a theoretical detection limit of 300 ppb over 100 s, resulting in an NNEA of 6×10−6 W cm−1 Hz−0.5. These results establish the f-mic as a robust, scalable solution for non-resonant PAS, effectively overcoming a significant bottleneck in compact gas sensing technologies.


  • Open Access

    Photoacoustic Gas Sensing Using a Novel Fluidic Microphone Based on Thermal MEMS

    by Akash Gupta, Anant Bhardwaj, Achim Bittner, Alfons Dehé

    Photoacoustic spectroscopy (PAS) is a powerful technique for selective gas detection; however, its performance in non-resonant configurations is fundamentally constrained by the poor low-frequency response of conventional acoustic detectors. Commercial MEMS microphones, although compact and cost-effective, exhibit limited infrasound sensitivity, which restricts the development of truly miniaturised and broadband PAS systems. To address this limitation, we present a novel MEMS fluidic microphone (f-mic) that operates on a thermal sensing principle and is explicitly optimised for the infrasound regime. The sensor demonstrates a constant sensitivity of 32 µV/Pa for frequencies below 20 Hz. A detailed analytical model incorporating frequency-dependent effects was developed to identify and investigate the critical design parameters that influence system performance. Based on these insights, a miniaturised photoacoustic cell was fabricated, ensuring efficient optical coupling and f-mic integration. Experimental validation using a CO2-targeted laser system demonstrates a linear response up to 5000 ppm, a sensitivity of 6 nV/ppm, and a theoretical detection limit of 300 ppb over 100 seconds, resulting in an NNEA of 6e-6 W cm^-1 Hz^-0.5. Long-term measurements indicate good stability, with minor drift primarily due to gas leakage and chopper fluctuations. These results establish the f-mic as a robust, scalable solution for non-resonant PAS, effectively overcoming a significant bottleneck in compact gas sensing technologies.


  • Open Access

    PT4.12 - SNR Enhancement of a MEMS Thermal Acoustic Pressure Sensor

    by A. Gupta, A. Bittner, A. Dehé

    In this work, we investigate the different internal noise mechanism affecting the performance of our MEMS based dynamic pressure sensor based on thermal anemometric principle [1]. We present sensitivity and noise measurements for two different chip designs for a comparative analysis with theoretical values. Finally, we show that the design modification resulted in the enhancement of the Signal to Noise ratio (SNR) by 30 dB and the dynamic pressure detection lower limit by a factor by 20 dBSPL.