Simon D. Westfechtel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Simon D. Westfechtel has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Daniel Truhn
Department for Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany
2 shared publications- Daniel Truhn
Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany
2 shared publications Sven Nebelung
Department for Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany
2 shared publicationsAlexandra Barabasch
Department for Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany
1 shared publicationCederic Aßmann
Department for Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany
1 shared publicationChristiane K. Kuhl
Department for Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany
1 shared publication
Latest Publications
- Open Access
- 8 September 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1) , 454
Anatomy-driven automated subsegmentation of pelvic and proximal femoral CT into clinically relevant subregions and landmarks
Background: The pelvis is among the most demanding regions in musculoskeletal imaging, and CT is its reference standard. Available automated tools, however, largely produce whole-bone or single-task masks, leaving the finer surgical subregions to slow, operator-dependent manual work. We developed a rule-based pipeline that converts pelvic and proximal femoral masks into a structured map of surgically meaningful subregions and landmarks, quantifying the manual correction burden required to achieve anatomically acceptable outputs. Methods: Anonymized pelvic CT scans were collected retrospectively; after predefined quality criteria, 757 of 1,316 screened normal adult cases were processed by a one-click pipeline in 3D Slicer. Parent structures from TotalSegmentator were divided by fixed anatomical rules into columns, acetabular regions, and proximal femoral regions. In 100 randomly selected cases, every segment was expert-reviewed and corrected where needed; correction frequency was the primary endpoint, with accuracy computed for corrected segments only. Pipeline performance was also assessed in a 60-case pathological-anatomy cohort for affected segments against manually segmented ground truth. Results: Of 8,100 segment observations, 93.8% were accepted without correction, and 51 of 81 segments required no correction in any case. Correction clustered in a few boundary regions, mainly the ischium and femoral neck (median 4.5 segments per case). Computed only on the corrected segments, the median Dice was 0.94, indicating that errors were modest where they occurred. A secondary symmetry analysis showed median surface agreement of 90% within 2 mm and 99.9% within 5 mm. In the pathological-anatomy cohort, pooled median Dice was 0.970 across affected components. Pooled landmark error was 5.37 mm median, with 91.9% of manual clicks inside the automated landmark. Conclusions: Validated in normal adult anatomy, this rule-based pipeline converts pelvic and proximal femoral CT into a structured hierarchy of clinically relevant subregions, needing only limited, predictable correction. It substantially reduces manual workload while preserving the anatomical detail needed for morphometry and dataset generation. Performance held up in an initial pathological-anatomy sample. Extension to fracture, deformity, or clinical decision-making requires dedicated validation in abnormal anatomy.
- 8 September 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1) , 454
Open AccessAnatomy-driven automated subsegmentation of pelvic and proximal femoral CT into clinically relevant subregions and landmarks
Background: The pelvis is among the most demanding regions in musculoskeletal imaging, and CT is its reference standard. Available automated tools, however, largely produce whole-bone or single-task masks, leaving the finer surgical subregions to slow, operator-dependent manual work. We developed a rule-based pipeline that converts pelvic and proximal femoral masks into a structured map of surgically meaningful subregions and landmarks, quantifying the manual correction burden required to achieve anatomically acceptable outputs. Methods: Anonymized pelvic CT scans were collected retrospectively; after predefined quality criteria, 757 of 1,316 screened normal adult cases were processed by a one-click pipeline in 3D Slicer. Parent structures from TotalSegmentator were divided by fixed anatomical rules into columns, acetabular regions, and proximal femoral regions. In 100 randomly selected cases, every segment was expert-reviewed and corrected where needed; correction frequency was the primary endpoint, with accuracy computed for corrected segments only. Pipeline performance was also assessed in a 60-case pathological-anatomy cohort for affected segments against manually segmented ground truth. Results: Of 8,100 segment observations, 93.8% were accepted without correction, and 51 of 81 segments required no correction in any case. Correction clustered in a few boundary regions, mainly the ischium and femoral neck (median 4.5 segments per case). Computed only on the corrected segments, the median Dice was 0.94, indicating that errors were modest where they occurred. A secondary symmetry analysis showed median surface agreement of 90% within 2 mm and 99.9% within 5 mm. In the pathological-anatomy cohort, pooled median Dice was 0.970 across affected components. Pooled landmark error was 5.37 mm median, with 91.9% of manual clicks inside the automated landmark. Conclusions: Validated in normal adult anatomy, this rule-based pipeline converts pelvic and proximal femoral CT into a structured hierarchy of clinically relevant subregions, needing only limited, predictable correction. It substantially reduces manual workload while preserving the anatomical detail needed for morphometry and dataset generation. Performance held up in an initial pathological-anatomy sample. Extension to fracture, deformity, or clinical decision-making requires dedicated validation in abnormal anatomy.
- Top Cited PapersOpen Access
Visual Large Language Models in Radiology: A Systematic Multimodel Evaluation of Diagnostic Accuracy and Hallucinations
Visual large language models (VLLMs) are discussed as potential tools for assisting radiologists in image interpretation, yet their clinical value remains unclear. This study provides a systematic and comprehensive comparison of general-purpose and biomedical VLLMs in radiology. We evaluated 180 representative clinical images with validated reference diagnoses (radiography, CT, MRI; 60 each) using seven VLLMs (ChatGPT-4o, Gemini 2.0, Claude Sonnet 3.7, Perplexity AI, Google Vision AI, LLaVA-1.6, LLaVA-Med-v1.5). Each model interpreted the image without and with clinical context. Mixed-effects logistic regression models assessed the influence of model, modality, and context on diagnostic performance and hallucinations (fabricated findings or misidentifications). Diagnostic accuracy varied significantly across all dimensions (p ≤ 0.001), ranging from 8.1% to 29.2% across models, with Gemini 2.0 performing best and LLaVA performing weakest. CT achieved the best overall accuracy (20.7%), followed by radiography (17.3%) and MRI (13.9%). Clinical context improved accuracy from 10.6% to 24.0% (p < 0.001) but shifted the model to rely more on textual information. Hallucinations were frequent (74.4% overall) and model-dependent (51.7–82.8% across models; p ≤ 0.004). Current VLLMs remain diagnostically unreliable, heavily context-biased, and prone to generating false findings, which limits their clinical suitability. Domain-specific training and rigorous validation are required before clinical integration can be considered.
Top Cited PapersOpen AccessVisual Large Language Models in Radiology: A Systematic Multimodel Evaluation of Diagnostic Accuracy and Hallucinations
Visual large language models (VLLMs) are discussed as potential tools for assisting radiologists in image interpretation, yet their clinical value remains unclear. This study provides a systematic and comprehensive comparison of general-purpose and biomedical VLLMs in radiology. We evaluated 180 representative clinical images with validated reference diagnoses (radiography, CT, MRI; 60 each) using seven VLLMs (ChatGPT-4o, Gemini 2.0, Claude Sonnet 3.7, Perplexity AI, Google Vision AI, LLaVA-1.6, LLaVA-Med-v1.5). Each model interpreted the image without and with clinical context. Mixed-effects logistic regression models assessed the influence of model, modality, and context on diagnostic performance and hallucinations (fabricated findings or misidentifications). Diagnostic accuracy varied significantly across all dimensions (p ≤ 0.001), ranging from 8.1% to 29.2% across models, with Gemini 2.0 performing best and LLaVA performing weakest. CT achieved the best overall accuracy (20.7%), followed by radiography (17.3%) and MRI (13.9%). Clinical context improved accuracy from 10.6% to 24.0% (p < 0.001) but shifted the model to rely more on textual information. Hallucinations were frequent (74.4% overall) and model-dependent (51.7–82.8% across models; p ≤ 0.004). Current VLLMs remain diagnostically unreliable, heavily context-biased, and prone to generating false findings, which limits their clinical suitability. Domain-specific training and rigorous validation are required before clinical integration can be considered.
- Open Access
- 17 May 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (11) , 6865-6878
AI in motion: the impact of data augmentation strategies on mitigating MRI motion artifacts
Objectives: Artifacts in clinical MRI can compromise the performance of AI models. This study evaluates how different data augmentation strategies affect an AI model’s segmentation performance under variable artifact severity. Materials and methods: We used an AI model based on the nnU-Net architecture to automatically quantify lower limb alignment using axial T2-weighted MR images. Three versions of the AI model were trained with different augmentation strategies: (1) no augmentation (“baseline”), (2) standard nnU-net augmentations (“default”), and (3) “default” plus augmentations that emulate MR artifacts (“MRI-specific”). Model performance was tested on 600 MR image stacks (right and left; hip, knee, and ankle) from 20 healthy participants (mean age, 23 ± 3 years, 17 men), each imaged five times under standardized motion to induce artifacts. Two radiologists graded each stack’s artifact severity as none, mild, moderate, and severe, and manually measured torsional angles. Segmentation quality was assessed using the Dice similarity coefficient (DSC), while torsional angles were compared between manual and automatic measurements using mean absolute deviation (MAD), intraclass correlation coefficient (ICC), and Pearson’s correlation coefficient (r). Statistical analysis included parametric tests and a Linear Mixed-Effects Model. Results: MRI-specific augmentation resulted in slightly (yet not significantly) better performance than the default strategy. Segmentation quality decreased with increasing artifact severity, which was partially mitigated by default and MRI-specific augmentations (e.g., severe artifacts, proximal femur: DSC baseline = 0.58 ± 0.22; DSC default = 0.72 ± 0.22; DSC MRI-specific = 0.79 ± 0.14 [ p < 0.001]). These augmentations also maintained precise torsional angle measurements (e.g., severe artifacts, femoral torsion: MAD baseline = 20.6 ± 23.5°; MAD default = 7.0 ± 13.0°; MAD MRI-specific = 5.7 ± 9.5° [ p < 0.001]; ICC baseline = −0.10 [ p = 0.63; 95% CI: −0.61 to 0.47]; ICC default = 0.38 [ p = 0.08; −0.17 to 0.76]; ICC MRI-specific = 0.86 [ p < 0.001; 0.62 to 0.95]; r baseline = 0.58 [ p < 0.001; 0.44 to 0.69]; r default = 0.68 [ p < 0.001; 0.56 to 0.77]; r MRI-specific = 0.86 [ p < 0.001; 0.81 to 0.9]). Conclusion: Motion artifacts negatively impact AI models, but general-purpose augmentations enhance robustness effectively. MRI-specific augmentations offer minimal additional benefit. Key Points: Question Motion artifacts negatively impact the performance of diagnostic AI models for MRI, but mitigation methods remain largely unexplored. Findings Domain-specific augmentation during training can improve the robustness and performance of a model for quantifying lower limb alignment in the presence of severe artifacts. Clinical relevance Excellent robustness and accuracy are crucial for deploying diagnostic AI models in clinical practice. Including domain knowledge in model training can benefit clinical adoption. Graphical
- 17 May 2025
- Published by Springer Nature in European Radiology
- Vol. 35 (11) , 6865-6878
Open AccessAI in motion: the impact of data augmentation strategies on mitigating MRI motion artifacts
Objectives: Artifacts in clinical MRI can compromise the performance of AI models. This study evaluates how different data augmentation strategies affect an AI model’s segmentation performance under variable artifact severity. Materials and methods: We used an AI model based on the nnU-Net architecture to automatically quantify lower limb alignment using axial T2-weighted MR images. Three versions of the AI model were trained with different augmentation strategies: (1) no augmentation (“baseline”), (2) standard nnU-net augmentations (“default”), and (3) “default” plus augmentations that emulate MR artifacts (“MRI-specific”). Model performance was tested on 600 MR image stacks (right and left; hip, knee, and ankle) from 20 healthy participants (mean age, 23 ± 3 years, 17 men), each imaged five times under standardized motion to induce artifacts. Two radiologists graded each stack’s artifact severity as none, mild, moderate, and severe, and manually measured torsional angles. Segmentation quality was assessed using the Dice similarity coefficient (DSC), while torsional angles were compared between manual and automatic measurements using mean absolute deviation (MAD), intraclass correlation coefficient (ICC), and Pearson’s correlation coefficient (r). Statistical analysis included parametric tests and a Linear Mixed-Effects Model. Results: MRI-specific augmentation resulted in slightly (yet not significantly) better performance than the default strategy. Segmentation quality decreased with increasing artifact severity, which was partially mitigated by default and MRI-specific augmentations (e.g., severe artifacts, proximal femur: DSC baseline = 0.58 ± 0.22; DSC default = 0.72 ± 0.22; DSC MRI-specific = 0.79 ± 0.14 [ p < 0.001]). These augmentations also maintained precise torsional angle measurements (e.g., severe artifacts, femoral torsion: MAD baseline = 20.6 ± 23.5°; MAD default = 7.0 ± 13.0°; MAD MRI-specific = 5.7 ± 9.5° [ p < 0.001]; ICC baseline = −0.10 [ p = 0.63; 95% CI: −0.61 to 0.47]; ICC default = 0.38 [ p = 0.08; −0.17 to 0.76]; ICC MRI-specific = 0.86 [ p < 0.001; 0.62 to 0.95]; r baseline = 0.58 [ p < 0.001; 0.44 to 0.69]; r default = 0.68 [ p < 0.001; 0.56 to 0.77]; r MRI-specific = 0.86 [ p < 0.001; 0.81 to 0.9]). Conclusion: Motion artifacts negatively impact AI models, but general-purpose augmentations enhance robustness effectively. MRI-specific augmentations offer minimal additional benefit. Key Points: Question Motion artifacts negatively impact the performance of diagnostic AI models for MRI, but mitigation methods remain largely unexplored. Findings Domain-specific augmentation during training can improve the robustness and performance of a model for quantifying lower limb alignment in the presence of severe artifacts. Clinical relevance Excellent robustness and accuracy are crucial for deploying diagnostic AI models in clinical practice. Including domain knowledge in model training can benefit clinical adoption. Graphical
- Open Access
- 19 January 2023
- Published by SAGE Publications in CARTILAGE
- Vol. 14 (1) , 26-38
Getting Cartilage Thickness Measurements Right: A Systematic Inter-Method Comparison Using MRI Data from the Osteoarthritis Initiative
Objective: Magnetic resonance imaging is the standard imaging modality to assess articular cartilage. As the imaging surrogate of degenerative joint disease, cartilage thickness is commonly quantified after tissue segmentation. In lack of a standard method, this study systematically compared five methods for automatic cartilage thickness measurements across the knee joint and as a function of region and sub-region: 3D mesh normals (3D-MN), 3D nearest neighbors (3D-NN), 3D ray tracing (3D-RT), 2D centerline normals (2D-CN), and 2D surface normals (2D-SN). Design: Based on the manually segmented femoral and tibial cartilage of 507 human knee joints, mean cartilage thickness was computed for the entire femorotibial joint, 4 joint regions, and 20 subregions using these methods. Inter-method comparisons of mean cartilage thickness and computation times were performed by one-way analysis of variance (ANOVA), Bland-Altman analyses and Lin’s concordance correlation coefficient (CCC). Results: Mean inter-method differences in cartilage thickness were significant in nearly all subregions ( P < 0.001). By trend, mean differences were smallest between 3D-MN and 2D-SN in most (sub)regions, which is also reflected by highest quantitative inter-method agreement and CCCs. 3D-RT was prone to severe overestimation of up to 2.5 mm. 3D-MN, 3D-NN, and 2D-SN required mean processing times of ≤5.3 s per joint and were thus similarly efficient, whereas the time demand of 2D-CN and 3D-RT was much larger at 133 ± 29 and 351 ± 10 s per joint ( P < 0.001). Conclusions: In automatic cartilage thickness determination, quantification accuracy and computational burden are largely affected by the underlying method. Mesh and surface normals or nearest neighbor searches should be used because they accurately capture variable geometries while being time-efficient.
- 19 January 2023
- Published by SAGE Publications in CARTILAGE
- Vol. 14 (1) , 26-38
Open AccessGetting Cartilage Thickness Measurements Right: A Systematic Inter-Method Comparison Using MRI Data from the Osteoarthritis Initiative
Objective: Magnetic resonance imaging is the standard imaging modality to assess articular cartilage. As the imaging surrogate of degenerative joint disease, cartilage thickness is commonly quantified after tissue segmentation. In lack of a standard method, this study systematically compared five methods for automatic cartilage thickness measurements across the knee joint and as a function of region and sub-region: 3D mesh normals (3D-MN), 3D nearest neighbors (3D-NN), 3D ray tracing (3D-RT), 2D centerline normals (2D-CN), and 2D surface normals (2D-SN). Design: Based on the manually segmented femoral and tibial cartilage of 507 human knee joints, mean cartilage thickness was computed for the entire femorotibial joint, 4 joint regions, and 20 subregions using these methods. Inter-method comparisons of mean cartilage thickness and computation times were performed by one-way analysis of variance (ANOVA), Bland-Altman analyses and Lin’s concordance correlation coefficient (CCC). Results: Mean inter-method differences in cartilage thickness were significant in nearly all subregions ( P < 0.001). By trend, mean differences were smallest between 3D-MN and 2D-SN in most (sub)regions, which is also reflected by highest quantitative inter-method agreement and CCCs. 3D-RT was prone to severe overestimation of up to 2.5 mm. 3D-MN, 3D-NN, and 2D-SN required mean processing times of ≤5.3 s per joint and were thus similarly efficient, whereas the time demand of 2D-CN and 3D-RT was much larger at 133 ± 29 and 351 ± 10 s per joint ( P < 0.001). Conclusions: In automatic cartilage thickness determination, quantification accuracy and computational burden are largely affected by the underlying method. Mesh and surface normals or nearest neighbor searches should be used because they accurately capture variable geometries while being time-efficient.