Tianxiang Qu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Tianxiang Qu has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Jiawei Xu
Fudan University
17 shared publications - Zhiliang Hong
Fudan University
17 shared publications - Liheng Liu
State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China
6 shared publications - Hao Li
State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China
3 shared publications - Qinjing Pan
State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, China
3 shared publications - Xiaoyang Zeng
Fudan University
3 shared publications
Latest Publications
- 18 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. PP (00189200) , 1-12
An Energy-Efficient and High-Accuracy Dual-ModeECG AI Processor via Deep-Fold and Zero-Free Fine-Grained Quantization
Smart wearable electrocardiography (ECG) devices require classification processors that combine high accuracy, low power dissipation, and real-time operation under stringent energy constraints. Conventional neural network approaches improve accuracy but are limited by high computational and memory costs, restricting on-chip deployment. This work presents an energy-efficient ECG AI processor enabled by algorithm-hardware co-design. Key contributions include: 1) a unified lightweight convolutional neural network (CNN) with a shared convolutional backbone and dual task-specific heads for binary and five-class classification; 2) a hardware-oriented deep-fold technique using weight symmetry to reduce parameters and multiplications by 39.1% and 40.1%, respectively; and 3) a zero-free fine-grained (ZFFG) quantization scheme that preserves accuracy at low bit-widths while enabling multiplier-less inference. Fabricated in 65-nm CMOS, the processor achieves 98.70% (binary) and 98.72% (five-class) classification accuracy with an ultra-compact 2.37 KB on-chip SRAM and only $0.09~{\mu }$ J per inference, representing a state-of-the-art, energy-efficient solution for real-time wearable ECG monitoring.
- 18 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. PP (00189200) , 1-12
An Energy-Efficient and High-Accuracy Dual-ModeECG AI Processor via Deep-Fold and Zero-Free Fine-Grained Quantization
Smart wearable electrocardiography (ECG) devices require classification processors that combine high accuracy, low power dissipation, and real-time operation under stringent energy constraints. Conventional neural network approaches improve accuracy but are limited by high computational and memory costs, restricting on-chip deployment. This work presents an energy-efficient ECG AI processor enabled by algorithm-hardware co-design. Key contributions include: 1) a unified lightweight convolutional neural network (CNN) with a shared convolutional backbone and dual task-specific heads for binary and five-class classification; 2) a hardware-oriented deep-fold technique using weight symmetry to reduce parameters and multiplications by 39.1% and 40.1%, respectively; and 3) a zero-free fine-grained (ZFFG) quantization scheme that preserves accuracy at low bit-widths while enabling multiplier-less inference. Fabricated in 65-nm CMOS, the processor achieves 98.70% (binary) and 98.72% (five-class) classification accuracy with an ultra-compact 2.37 KB on-chip SRAM and only $0.09~{\mu }$ J per inference, representing a state-of-the-art, energy-efficient solution for real-time wearable ECG monitoring.
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 8, 361-364
A 560 μ W, 6 fA/√Hz, 146 dB-DR Ultrasensitive Current Readout Circuit for PWM-Dimming-Tolerant Under-Display Ambient Light Sensors
This letter presents an ultra-low-noise, powerefficient, and PWM-dimming-tolerant photocurrent readout circuit for under-display ambient light sensors (ALS). A transimpedance amplifier (TIA) with a feedback diode achieves GΩ-level resistance and 6 fA/Hz input current noise, enabling sub-pA resolution. Instability and noise folding are mitigated at low power through a signal-dependent auto-tracking zero for frequency compensation and a low-pass filter for high-frequency noise suppression. A 2-point calibration algorithm improves the linearity of the current-to-frequency (I2F) quantizer without incurring additional power. To extract ambient light in the presence of PWM dimming interference, the readout supports under-sampling, allowing digital cancellation of interference. Fabricated in 180 nm CMOS, the prototype achieves 0.36 pApp resolution, 146.3 dB dynamic range (DR), and a 206.3 dB FoMDR in 0.84 ms readout time, representing best-in-class performance. Optical ALS measurements under PWM dimming interference are experimentally validated.
- 30 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 8, 361-364
A 560 μ W, 6 fA/√Hz, 146 dB-DR Ultrasensitive Current Readout Circuit for PWM-Dimming-Tolerant Under-Display Ambient Light Sensors
This letter presents an ultra-low-noise, powerefficient, and PWM-dimming-tolerant photocurrent readout circuit for under-display ambient light sensors (ALS). A transimpedance amplifier (TIA) with a feedback diode achieves GΩ-level resistance and 6 fA/Hz input current noise, enabling sub-pA resolution. Instability and noise folding are mitigated at low power through a signal-dependent auto-tracking zero for frequency compensation and a low-pass filter for high-frequency noise suppression. A 2-point calibration algorithm improves the linearity of the current-to-frequency (I2F) quantizer without incurring additional power. To extract ambient light in the presence of PWM dimming interference, the readout supports under-sampling, allowing digital cancellation of interference. Fabricated in 180 nm CMOS, the prototype achieves 0.36 pApp resolution, 146.3 dB dynamic range (DR), and a 206.3 dB FoMDR in 0.84 ms readout time, representing best-in-class performance. Optical ALS measurements under PWM dimming interference are experimentally validated.
- Open Access
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 5, 251-268
Analog Front-End Circuit Techniques for Wearable ExG, BioZ, and PPG Signal Acquisition: A Review
Wearable platforms that concurrently acquire multiple physiological signals enable comprehensive health monitoring but impose stringent requirements on front-end circuit design. The reliable extraction of low-amplitude and low-frequency biosignals is hindered by electrode offset, noise, motion artifacts, and environmental interference. Recent efforts have advanced analog front ends (AFEs) for biopotential (ExG), bioimpedance (BioZ), and photoplethysmography (PPG) sensing, with emphasis on optimizing key metrics such as noise efficiency, input impedance, dynamic range, CMRR, and power consumption. In addition, digitally assisted calibration and direct-digitization schemes have emerged as alternative design directions, offering enhanced robustness and scalability while introducing trade-offs in complexity and energy efficiency. This review surveys these circuit techniques, analyzes their design trade-offs, and outlines future opportunities for next-generation wearable biomedical interfaces.
- 16 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 5, 251-268
Open AccessAnalog Front-End Circuit Techniques for Wearable ExG, BioZ, and PPG Signal Acquisition: A Review
Wearable platforms that concurrently acquire multiple physiological signals enable comprehensive health monitoring but impose stringent requirements on front-end circuit design. The reliable extraction of low-amplitude and low-frequency biosignals is hindered by electrode offset, noise, motion artifacts, and environmental interference. Recent efforts have advanced analog front ends (AFEs) for biopotential (ExG), bioimpedance (BioZ), and photoplethysmography (PPG) sensing, with emphasis on optimizing key metrics such as noise efficiency, input impedance, dynamic range, CMRR, and power consumption. In addition, digitally assisted calibration and direct-digitization schemes have emerged as alternative design directions, offering enhanced robustness and scalability while introducing trade-offs in complexity and energy efficiency. This review surveys these circuit techniques, analyzes their design trade-offs, and outlines future opportunities for next-generation wearable biomedical interfaces.
- 17 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (10) , 3474-3483
A 2.06-zF rms Resolution Lock-In Amplifier With SAR-Assisted Parasitic and Baseline Capacitance Compensation
This article presents the design and implementation of a precision lock-in amplifier for universal capacitive sensing. While conventional capacitive transimpedance amplifier (C-TIA) based on lock-in detection can extract subtle capacitance changes from a noisy environment, the capacitance resolution is further limited by parasitic capacitance at the input node, the baseline capacitance of the sensor, and current noise introduced by input bias resistor. To address these limitations, this work proposes a zeptofarad (zF) resolution lock-in amplifier using three key techniques: 1) a self-calibrated negative capacitor (NC) to cancel the parasitic capacitance at C-TIA input; 2) baseline capacitance compensation to improve the dynamic range (DR), allowing the use of higher excitation voltages, thereby improving the SNR; and 3) multi-element pseudo-resistor (PR) to mitigate shot noise in the presence of elevated input dc current. The proposed lock-in amplifier was implemented in a standard 180-nm CMOS process, achieving a best-in-class resolution of 2.06 zF ${}_{\mathbf {rms}}$ (BW = 10 Hz) while tolerating a maximum input dc current of 122 nA. This amplifier enables wideband lock-in detection from 1 kHz to 62 MHz. Both parasitic and baseline capacitance can be automatically calibrated in the foreground, considerably improving the speed and practicality of the measurement.
- 17 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (10) , 3474-3483
A 2.06-zF rms Resolution Lock-In Amplifier With SAR-Assisted Parasitic and Baseline Capacitance Compensation
This article presents the design and implementation of a precision lock-in amplifier for universal capacitive sensing. While conventional capacitive transimpedance amplifier (C-TIA) based on lock-in detection can extract subtle capacitance changes from a noisy environment, the capacitance resolution is further limited by parasitic capacitance at the input node, the baseline capacitance of the sensor, and current noise introduced by input bias resistor. To address these limitations, this work proposes a zeptofarad (zF) resolution lock-in amplifier using three key techniques: 1) a self-calibrated negative capacitor (NC) to cancel the parasitic capacitance at C-TIA input; 2) baseline capacitance compensation to improve the dynamic range (DR), allowing the use of higher excitation voltages, thereby improving the SNR; and 3) multi-element pseudo-resistor (PR) to mitigate shot noise in the presence of elevated input dc current. The proposed lock-in amplifier was implemented in a standard 180-nm CMOS process, achieving a best-in-class resolution of 2.06 zF ${}_{\mathbf {rms}}$ (BW = 10 Hz) while tolerating a maximum input dc current of 122 nA. This amplifier enables wideband lock-in detection from 1 kHz to 62 MHz. Both parasitic and baseline capacitance can be automatically calibrated in the foreground, considerably improving the speed and practicality of the measurement.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1132-1141
A 101-dB DR 2.2GΩ-Input-Impedance Direct Digitization ExG Front-End With Δ-Modulation
Long-term, continuous health monitoring imposes stringent demands on bio-recording analog front-end (AFE) circuits, specifically in terms of dynamic range (DR), noise, input impedance, and power consumption. This work introduces a DR-enhanced direct-digitization AFE based on a Δ-modulated transconductor (TC) stage, followed by a second-order ΔΣ ADC. In this architecture, the accumulated DAC is subtracted exclusively at the TC input stage, allowing the integrators to process only the low-amplitude Δ-modulated signal and thus relaxing the dynamic range constraints of conventional Gm-C ΔΣ ADCs. The TC input stage achieves high input impedance and high linearity through a current-balancing transconductor and a flipped-voltage-follower (FVF) loop. Fabricated with a standard 180nm CMOS process, the proposed Δ-ΔΣ AFE exhibits an SNDR of 91 dB, a dynamic range of 101 dB, input referred noise of 58 nV/√Hz, and a power consumption of 63 μW. These results correspond to a FoMSNDR of 160.1 dB and a FoMDR of 170 dB. The AFE prototype has been validated through scalp EEG, leg EMG, and chest ECG with significant body movements, demonstrating its effectiveness as a motion-artifact-tolerant direct-ADC front end.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1132-1141
A 101-dB DR 2.2GΩ-Input-Impedance Direct Digitization ExG Front-End With Δ-Modulation
Long-term, continuous health monitoring imposes stringent demands on bio-recording analog front-end (AFE) circuits, specifically in terms of dynamic range (DR), noise, input impedance, and power consumption. This work introduces a DR-enhanced direct-digitization AFE based on a Δ-modulated transconductor (TC) stage, followed by a second-order ΔΣ ADC. In this architecture, the accumulated DAC is subtracted exclusively at the TC input stage, allowing the integrators to process only the low-amplitude Δ-modulated signal and thus relaxing the dynamic range constraints of conventional Gm-C ΔΣ ADCs. The TC input stage achieves high input impedance and high linearity through a current-balancing transconductor and a flipped-voltage-follower (FVF) loop. Fabricated with a standard 180nm CMOS process, the proposed Δ-ΔΣ AFE exhibits an SNDR of 91 dB, a dynamic range of 101 dB, input referred noise of 58 nV/√Hz, and a power consumption of 63 μW. These results correspond to a FoMSNDR of 160.1 dB and a FoMDR of 170 dB. The AFE prototype has been validated through scalp EEG, leg EMG, and chest ECG with significant body movements, demonstrating its effectiveness as a motion-artifact-tolerant direct-ADC front end.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1120-1131
A 6.4GΩ-Input-Impedance 104.5dB-CMRR 96dB-DR DD-AFE With Tri-Level IDAC for Small-Diameter Dry-Electrode Interfaces
This article presents a direct-digitization analog front end (DD-AFE) with enhanced input-impedance, common-mode rejection ratio (CMRR), and dynamic range (DR) for wearable biopotential (ExG) signal acquisition, especially for small-diameter dry electrodes. The DD-AFE employs a second-order continuous-time delta-sigma modulator (CT-ΔSM) and multiple circuit techniques to support direct-digitization readouts. These include 1) A high input-impedance input feedforward (FF), embedded in a 4-input 4-bit successive approximation register (SAR) quantizer. This allows two integrators to adopt a compact and energy-efficient Gm-C structure, and improves stability and linearity, resulting in a 6.6dB increase in DR, 42dB increase in SQNR at peak input and a unity-gain signal transfer function (STF) with a gain flatness of 0.04%. 2) A fixed-voltage dead-band assisted tri-level current-steering DAC (IDAC). It not only increases the DR and CMRR of the DD-AFE but also eliminates the harmonic distortion induced by tri-level dynamic element matching (DEM). 3) A high-gain two-stage Gm-boosting inverter-based OTA with embedded low-frequency chopping. The former largely improves linearity and CMRR, while the latter mitigates 1/f noise without compromising the input impedance. Fabricated in a 0.18-μm CMOS process, this DD-AFE achieves 6.4GΩ input impedance and 104.5dB CMRR at 50Hz, as well as 90.4dB peak SNDR, 96dB DR, and up to 425mVPP linear input range.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1120-1131
A 6.4GΩ-Input-Impedance 104.5dB-CMRR 96dB-DR DD-AFE With Tri-Level IDAC for Small-Diameter Dry-Electrode Interfaces
This article presents a direct-digitization analog front end (DD-AFE) with enhanced input-impedance, common-mode rejection ratio (CMRR), and dynamic range (DR) for wearable biopotential (ExG) signal acquisition, especially for small-diameter dry electrodes. The DD-AFE employs a second-order continuous-time delta-sigma modulator (CT-ΔSM) and multiple circuit techniques to support direct-digitization readouts. These include 1) A high input-impedance input feedforward (FF), embedded in a 4-input 4-bit successive approximation register (SAR) quantizer. This allows two integrators to adopt a compact and energy-efficient Gm-C structure, and improves stability and linearity, resulting in a 6.6dB increase in DR, 42dB increase in SQNR at peak input and a unity-gain signal transfer function (STF) with a gain flatness of 0.04%. 2) A fixed-voltage dead-band assisted tri-level current-steering DAC (IDAC). It not only increases the DR and CMRR of the DD-AFE but also eliminates the harmonic distortion induced by tri-level dynamic element matching (DEM). 3) A high-gain two-stage Gm-boosting inverter-based OTA with embedded low-frequency chopping. The former largely improves linearity and CMRR, while the latter mitigates 1/f noise without compromising the input impedance. Fabricated in a 0.18-μm CMOS process, this DD-AFE achieves 6.4GΩ input impedance and 104.5dB CMRR at 50Hz, as well as 90.4dB peak SNDR, 96dB DR, and up to 425mVPP linear input range.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1078-1090
A 44µW Two-Electrode ECG Acquisition ASIC With Hybrid Motion Artifact Removal and Power-Efficient R -Peak Detection
Motion artifacts (MA), common-mode interference (CMI), and varying electrode-tissue impedance (ETI) are the main factors that cause heart rate detection errors in practical wearable ECG acquisition. These problems are further exacerbated in two-electrode based ECG systems. This article presents an ambulatory ECG acquisition ASIC with fully integrated, low power motion artifacts removal (MAR) and heart rate detection, specifically for two-electrode ECG measurement. To alleviate the significant CMI due to the absence of subject bias electrode, this work utilizes an improved common-mode cancellation scheme to suppress CMI up to 40Vpp with dynamic power consumption. To address excessive MA caused by the body movement, a hybrid MAR technique is proposed, where both ETI and DC electrode offset (DEO) signals are incorporated as inputs to the adaptive filter. This approach not only prevents channel saturation in a power-efficient manner, but also accurately extracts MA and suppresses it in real time, thereby ensuring stable ECG outputs and accurate, power-efficient R-peak detection even in the presence of body movements. Fabricated in a standard 180nm CMOS process, the core IA achieves an input referred noise (IRN) of 0.62μVrms (1-150Hz), an input impedance of 1.9GΩ and a total-CMRR (T-CMRR) of 92dB at 50Hz. In a two-electrode configuration, the ASIC successfully suppresses the MA and obtains a high-quality ECG with well-identified QRS complex, enabling the built-in R-peak detection algorithm to calculate real-time heart rate more accurately and efficiently.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (6) , 1078-1090
A 44µW Two-Electrode ECG Acquisition ASIC With Hybrid Motion Artifact Removal and Power-Efficient R -Peak Detection
Motion artifacts (MA), common-mode interference (CMI), and varying electrode-tissue impedance (ETI) are the main factors that cause heart rate detection errors in practical wearable ECG acquisition. These problems are further exacerbated in two-electrode based ECG systems. This article presents an ambulatory ECG acquisition ASIC with fully integrated, low power motion artifacts removal (MAR) and heart rate detection, specifically for two-electrode ECG measurement. To alleviate the significant CMI due to the absence of subject bias electrode, this work utilizes an improved common-mode cancellation scheme to suppress CMI up to 40Vpp with dynamic power consumption. To address excessive MA caused by the body movement, a hybrid MAR technique is proposed, where both ETI and DC electrode offset (DEO) signals are incorporated as inputs to the adaptive filter. This approach not only prevents channel saturation in a power-efficient manner, but also accurately extracts MA and suppresses it in real time, thereby ensuring stable ECG outputs and accurate, power-efficient R-peak detection even in the presence of body movements. Fabricated in a standard 180nm CMOS process, the core IA achieves an input referred noise (IRN) of 0.62μVrms (1-150Hz), an input impedance of 1.9GΩ and a total-CMRR (T-CMRR) of 92dB at 50Hz. In a two-electrode configuration, the ASIC successfully suppresses the MA and obtains a high-quality ECG with well-identified QRS complex, enabling the built-in R-peak detection algorithm to calculate real-time heart rate more accurately and efficiently.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An IoT-Enabled Wearable Health Monitor for Synchronized ExG, PPG, and BioZ Measurement
The multimodal wearable health monitor is designed for patients with chronic conditions and leverage edge data pre-processing for efficiency. It supports a variety of use cases: a brain monitoring headband for measuring electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS), a chest health patch for sensing electrocardiography (ECG), RR intervals (RRI), bioimpedance (BioZ), and photoplethysmography (PPG), and a fitness legband for recording electromyograph (EMG) and PPG. Similar devices can also be connected to a Body Sensor Network for comprehensive health monitoring. The system includes a flexible PPG sensor and a data acquisition (DAQ) board with integrated bioimpedance and biopotential channels. They feature a low input-referred noise level of 25 pArms (BW=10 Hz), 6.06 Ωrms (BW=0.05-4 Hz), and 0.77 μVrms (BW=0.05-150 Hz), respectively. The multimodal health monitor consumes 30.4 mW of power and can operate continuously for 36 hours. The flexible sensor, with a 1 cm diameter and a bending radius of 66.6 μm, conforms to the skin for versatile detection. Edge data pre-processing and offloading tasks to the PC helps reduce data redundancy and latency. The overall platform enables remote real-time monitoring, historical data queries, and email alerts. The results indicate that the average correlation of EEG signals was 96.21% in the eyes-open and eyes-closed tests, and the alpha rhythm was clear. During the breath-holding test, the SpO2 level changed by 10%. In chest synchronization, the heart rate increased by 2 bpm every 3 seconds. The Mean Absolute Error (MAE) of the heart rate test for five subjects was 1.38%, and the Mean Absolute Percentage Error (MAPE) was 1.98%.
- 19 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
An IoT-Enabled Wearable Health Monitor for Synchronized ExG, PPG, and BioZ Measurement
The multimodal wearable health monitor is designed for patients with chronic conditions and leverage edge data pre-processing for efficiency. It supports a variety of use cases: a brain monitoring headband for measuring electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS), a chest health patch for sensing electrocardiography (ECG), RR intervals (RRI), bioimpedance (BioZ), and photoplethysmography (PPG), and a fitness legband for recording electromyograph (EMG) and PPG. Similar devices can also be connected to a Body Sensor Network for comprehensive health monitoring. The system includes a flexible PPG sensor and a data acquisition (DAQ) board with integrated bioimpedance and biopotential channels. They feature a low input-referred noise level of 25 pArms (BW=10 Hz), 6.06 Ωrms (BW=0.05-4 Hz), and 0.77 μVrms (BW=0.05-150 Hz), respectively. The multimodal health monitor consumes 30.4 mW of power and can operate continuously for 36 hours. The flexible sensor, with a 1 cm diameter and a bending radius of 66.6 μm, conforms to the skin for versatile detection. Edge data pre-processing and offloading tasks to the PC helps reduce data redundancy and latency. The overall platform enables remote real-time monitoring, historical data queries, and email alerts. The results indicate that the average correlation of EEG signals was 96.21% in the eyes-open and eyes-closed tests, and the alpha rhythm was clear. During the breath-holding test, the SpO2 level changed by 10%. In chest synchronization, the heart rate increased by 2 bpm every 3 seconds. The Mean Absolute Error (MAE) of the heart rate test for five subjects was 1.38%, and the Mean Absolute Percentage Error (MAPE) was 1.98%.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 8, 49-52
A 0.86 mW 17 fA/√Hz, 129-dB DR Current-Sensing Front-End for Under-Display Ambient Light Sensor With Zero-Compensated Logarithmic TIA
This letter presents a low noise, power-efficient, and pulsatile-interference stabilized photocurrent readout circuit for under-display ambient light sensors (ALS). To achieve pA-level input noise and seven decades of input current dynamic range simultaneously, a logarithmic transimpedance amplifier (TIA) with a diode-connected MOS feedback is set as the first stage of the ALS. An auto-tracking zero, implemented in the amplifier of the TIA, improves the phase-margin and reduces the settling time against pulsatile interference without extra power consumption. The TIA output is then quantized by a 1st-order 9-bit incremental delta-sigma modulator. Fabricated in a standard 0.18lm CMOS process, the proposed ALS achieves the best-in-the-class input-referred current noise of 0.6pArms within a 400ls readout time. The total input range of 1.7pAPP-5lAPP corresponds to a dynamic range of 129dB while consuming 0.86mW at a 1.8V supply.
- 13 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 8, 49-52
A 0.86 mW 17 fA/√Hz, 129-dB DR Current-Sensing Front-End for Under-Display Ambient Light Sensor With Zero-Compensated Logarithmic TIA
This letter presents a low noise, power-efficient, and pulsatile-interference stabilized photocurrent readout circuit for under-display ambient light sensors (ALS). To achieve pA-level input noise and seven decades of input current dynamic range simultaneously, a logarithmic transimpedance amplifier (TIA) with a diode-connected MOS feedback is set as the first stage of the ALS. An auto-tracking zero, implemented in the amplifier of the TIA, improves the phase-margin and reduces the settling time against pulsatile interference without extra power consumption. The TIA output is then quantized by a 1st-order 9-bit incremental delta-sigma modulator. Fabricated in a standard 0.18lm CMOS process, the proposed ALS achieves the best-in-the-class input-referred current noise of 0.6pArms within a 400ls readout time. The total input range of 1.7pAPP-5lAPP corresponds to a dynamic range of 129dB while consuming 0.86mW at a 1.8V supply.