STShuyuan Tang

Shuyuan Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shuyuan Tang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Bo Yu

    Science and Technology Innovation Center of Wildland Fire Prevention and Control of Beihua University, Forestry College, Beihua University, 3999 Binjiang East Road, Jilin 132013, China

    3 shared publications
  • Chenxi Cui

    Science and Technology Innovation Center of Wildland Fire Prevention and Control of Beihua University, Forestry College, Beihua University, 3999 Binjiang East Road, Jilin 132013, China

    3 shared publications
  • Lili Cao

    Science and Technology Innovation Center of Wildland Fire Prevention and Control of Beihua University, Forestry College, Beihua University, 3999 Binjiang East Road, Jilin 132013, China

    3 shared publications
  • Sainan Yin

    Science and Technology Innovation Center of Wildland Fire Prevention and Control of Beihua University, Forestry College, Beihua University, Jilin 132013, China

    3 shared publications
  • Yanlong Shan

    Science and Technology Innovation Center of Wildland Fire Prevention and Control of Beihua University, Forestry College, Beihua University, Jilin 132013, China

    3 shared publications
  • Grahame Douglas

    School of Engineering, Design and Built Environment, Western Sydney University, Coffs Harbour, NSW 2450, Australia

    1 shared publication

Latest Publications

  • Open Access

    Study on the Limit of Moisture Content of the Sub-Surface Fires Converted to the Surface Fires in the Boreal Forests of China

    by Yanlong Shan, Xiang Chen, Sainan Yin, Lili Cao, Shuyuan Tang, Bo Yu, Chenxi Cui

    A sub-surface forest fire is a type of smoldering combustion with a slower spread rate, longer combustion time, and lower combustion temperature compared with flame combustion. Sub-surface fires are usually accompanied by surface fires, and the surface fires’ conversion from sub-surface fires has great uncertainty. Therefore, there are considerable difficulties in monitoring and fighting sub-surface fires. However, there are few studies on the conversion from sub-surface fires to surface fires, and the mechanism and influencing factors of the conversion remain unclear. This study focuses on Larix gmelinii forests, which are representative of the boreal forest of China and hot spots of sub-surface fires, studies the moisture content limit of sub-surface fires’ conversion to surface fires by simulating a smoldering experiment, and establishes a monitoring model of sub-surface fires and an occurrence probability prediction model of sub-surface fires’ conversion to surface fires. The results showed that the moisture content limit of the conversion was 25% in the grass–Larix gmelinii forest and Ledum palustre–Larix gmelinii forest and 20% in Rhododendron dauricum–Larix gmelinii forest. There was a significant positive correlation between the time and temperature caused by the smoldering. The monitoring model of the sub-surface fires based on the surface temperature and moisture content had a good fitting effect (p < 0.01). The occurrence probability prediction model of the sub-surface fires’ conversion to surface fires, based on a logistic regression model, had high prediction accuracy (AUC = 0.987). The lower the moisture content of the humus, the closer the smoldering came to the surface and the higher the probability of conversion. This research could contribute to the study of the mechanism of sub-surface fires’ conversion into surface fires.


  • Open Access

    The Characteristics of Gas and Particulate Emissions from Smouldering Combustion in the Pinus pumila Forest of Huzhong National Nature Reserve of the Daxing’an Mountains

    by Shuyuan Tang, Sainan Yin, Yanlong Shan, Bo Yu, Chenxi Cui, Lili Cao

    Smouldering combustion can emit a large amount of CO2, CO and particulate matter (PM). Moisture content is an important factor of the emission characteristics. As the hot spot of forest smouldering combustion, the gas and particulate emissions of the Huzhong National Nature Reserve with different moisture contents are discussed herein. The emission factors (EF) of CO2 and CO were 100.71 ± 39.14 g/kg and 11.76 ± 3.89 g/kg, respectively. The EF of PM2.5, PM4 and PM10 were 87.11 ± 19.47 g/kg, 353.37 ±159.25 g/kg and 602.59 ± 276.80 g/kg, respectively. PM2.5 accounted for 16.59 ± 5.25% of the PM, and PM4 and PM10 were 54.03 ± 13.46% and 91.00 ± 10.81%, respectively. There was no significant difference in the EF of CO2 and CO with different moisture contents, nor in the EF of PM2.5, but there was a significant difference in the EF of PM4 and PM10 with different moisture contents. In addition, the peak of CO2 and CO appeared at 2~3 h; the peak of PM2.5 lagged behind that of PM4 and PM10. According to the regression analysis, experimental expressions were obtained for the modified combustion efficiency (MCE) and the EF of PM.


  • Open Access

    Study on the Limit of Moisture Content of Smoldering Humus during Sub-Surface Fires in the Boreal Forests of China

    by Sainan Yin, Yanlong Shan, Shuyuan Tang, Grahame Douglas, Bo Yu, Chenxi Cui, Lili Cao

    A sub-surface forest fire is a kind of fire that spreads slowly with no flames and lower temperatures, and threatens the ecosystem and human life. The moisture content of humus is considered to be an important factor in determining fire occurrence and sustaining. The humus of the Larix gmelinii in the Daxing’an Mountains was selected for the experiment, the limit moisture content condition of sub-surface forest fires was determined by an experiment simulating smoldering, and the prediction model of the probability of sub-surface forest fire occurrence was established. The results will be of great significance for the prevention, monitoring, and fighting of sub-surface forest fires in the boreal forest. The results showed that when the moisture content of humus in the upper layer was low, the smoldering process could be self-sustaining at 20%. For deeper layers of a depth of 18 cm, this increased to 30% moisture content of the humus and was the critical depth for sub-surface fires. The moisture content of 40% was a limit to burning where smoldering can only last for a short duration and is then extinguished. When the moisture content of the humus was 20%, the smoldering temperature was higher and the rate of spread was faster, with smoldering being maintained for longer periods at 30% moisture content. The regression prediction model of the highest temperature and vertical rate of spread in a column of humus was correlated to moisture content and depth, and the model significance was good at p < 0.01. Based on moisture content and depth, the occurrence probability prediction model of sub-surface fires has a good correlation (R2 = 0.93) and high prediction accuracy (AUC = 0.995). The effect of moisture content (Or = 4.008) on the occurrence probability of sub-surface fires is higher than that of depth (Or = 2.948). The results point out that it is necessary to prevent and monitor the occurrence of sub-surface fires when the humus moisture content is less than 40%. In order to reduce the risk of sub-surface fires, the monitoring time of the fire field should be extended after the fire is extinguished due to the slow-burning process of the sub-surface fire. Increasing the moisture content of the humus is an important method to reduce the probability and restrain the spread of sub-surface fires.