Siddiq Wahyu Hidayat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Siddiq Wahyu Hidayat has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Wuwus Ardiatna
National Research and Innovation Agency
3 shared publications - Asep Rahmat Hidayat
National Research and Innovation Agency Republic of Indonesia
2 shared publications - Ihsan Supono
Research Center for Testing Technology and Standards, National Research and Innovation Agency (BRIN), Tangerang
2 shared publications - Sensus Wijonarko
Research Center for Photonics, National Research and Innovation Agency, Tangerang Selatan 15314, Indonesia
2 shared publications - Tatik Maftukhah
Research Center for Photonics, National Research and Innovation Agency, Tangerang Selatan 15314, Indonesia
2 shared publications - Vera Permatasari
Research Center for Pharmaceutical Ingredients and Traditional Medicine, National Research and Innovation Agency (BRIN), Kawasan Sains dan Teknologi (KST), BJ Habibie (PUSPIPTEK) Serpong, South Tangerang, Banten, Indonesia
2 shared publications
Latest Publications
- 1 June 2026
- Published by Kyushu University in Evergreen
- Vol. 13 (2) , 738-749
The Effects of Piper nigrum Soaking Temperature, Density, and Sacking on its Stiffness Measured Using our Tailor Made Pepper Stiffness Instrument
- 1 June 2026
- Published by Kyushu University in Evergreen
- Vol. 13 (2) , 738-749
The Effects of Piper nigrum Soaking Temperature, Density, and Sacking on its Stiffness Measured Using our Tailor Made Pepper Stiffness Instrument
- 1 March 2026
- Published by Kyushu University in Evergreen
- Vol. 13 (1) , 364-372
Evaluation of Sphygmomanometer Dial Performance Across Variable Temperatures and Pressure Conditions
- 1 March 2026
- Published by Kyushu University in Evergreen
- Vol. 13 (1) , 364-372
Evaluation of Sphygmomanometer Dial Performance Across Variable Temperatures and Pressure Conditions
- Open Access
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1708-1716
A Method to Present the Uniqueness for Uniform Program Applied in Irrigation Telecontrol
- 1 September 2023
- Published by Kyushu University in Evergreen
- Vol. 10 (3) , 1708-1716
Open AccessA Method to Present the Uniqueness for Uniform Program Applied in Irrigation Telecontrol
- Open Access
- 1 February 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (1) , 1152-1160
Real-time wireless temperature measurement system of infant incubator
The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.
- 1 February 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 13 (1) , 1152-1160
Open AccessReal-time wireless temperature measurement system of infant incubator
The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 205-209
EMI risk analysis via dedicated evaluation of the susceptibility of medical devices
This paper focuses on the Electro-Magnetic Interference Risk Analysis of medical devices via the evaluation of their susceptibility. Medical devices for supporting patients' life are frequently applied in vulnerable environments such as hospitals and surgery rooms. The susceptibility analysis is based on a GTEM testing method derived from ANSI C63.18 and is applied to three different medical devices, namely ECG, patient monitor and an infusion pump. Specific interference signals are generated simulating telecommunication devices, more specifically Wi-Fi, GSM, and PMR. The results showed that especially the signals transmitted by the PMR may affect the performance of medical devices.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 205-209
EMI risk analysis via dedicated evaluation of the susceptibility of medical devices
This paper focuses on the Electro-Magnetic Interference Risk Analysis of medical devices via the evaluation of their susceptibility. Medical devices for supporting patients' life are frequently applied in vulnerable environments such as hospitals and surgery rooms. The susceptibility analysis is based on a GTEM testing method derived from ANSI C63.18 and is applied to three different medical devices, namely ECG, patient monitor and an infusion pump. Specific interference signals are generated simulating telecommunication devices, more specifically Wi-Fi, GSM, and PMR. The results showed that especially the signals transmitted by the PMR may affect the performance of medical devices.