S. Motta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
S. Motta has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Gardenali Yukihara
Paul Scherrer Institute (PSI)
5 shared publications - Jeppe Brage Christensen
Paul Scherrer Institute (PSI)
3 shared publications A J Lomax
Center for Proton Therapy, Paul Scherrer Institute, Villigen PSI, SWITZERLAND
1 shared publicationF Frei
Federal Institute of Metrology
1 shared publicationJ.B. Christensen
1 shared publication- Lily Bossin
Department of Radiation Safety and Security, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
1 shared publication
Latest Publications
- Open Access
- 10 October 2024
- Published by Elsevier in Radiation Measurements
- Vol. 179
Assessing dose rate effects in TL and OSL dosimeters: A critical look into dose rate models
- 10 October 2024
- Published by Elsevier in Radiation Measurements
- Vol. 179
Open AccessAssessing dose rate effects in TL and OSL dosimeters: A critical look into dose rate models
- Open Access
- 2 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (3) , 035022
Dosimetry of ultra-high dose rate electron beams using thermoluminescence and optically stimulated luminescence detectors
Objective. The aim of this work is to investigate the dose rate dependence of thermoluminescence and optically stimulated luminescence detectors (TLDs and OSLDs) in a wide uniform ultra-high dose rate electron beam and demonstrate the potential use of TLDs and OSLDs to correct the ion recombination in air-filled ionization chambers. This study avoids previously reported complications related to the field size and homogeneity. Approach. Two types of OSLDs (BeO and Al 2 O 3 :C) and three types of TLDs (LiF:Mg,Ti, LiF:Mg,Cu,P, CaF 2 :Tm) were irradiated simultaneously in a uniform 16 MeV electron beam generated by a clinically decommissioned C-Arm LINAC, modified to deliver doses per pulse between 8.3 × 10 −4 Gy and 1.255 Gy, corresponding to instantaneous dose rates between 2 × 10 2 Gy s −1 and 3 × 10 5 Gy s −1 . A prototype ultra-thin parallel plate ionization chamber was employed as reference detector. Main results. Reproducible results were achieved both at conventional (standard deviation of the data 2 O 3 :C OSLD was found to be the most precise detector, with a standard deviation of the data Significance. The dose rate independence of the investigated TLDs and OSLDs make them good candidates for dosimetry at ultra-high dose rates, at least up to 3 × 10 5 Gy s −1 . A dose rate independent method to measure the dose per pulse is proposed, which can be applied to characterize ultra-high dose rate electron beams and correct for ion recombination in ionization chambers.
- 2 February 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (3) , 035022
Open AccessDosimetry of ultra-high dose rate electron beams using thermoluminescence and optically stimulated luminescence detectors
Objective. The aim of this work is to investigate the dose rate dependence of thermoluminescence and optically stimulated luminescence detectors (TLDs and OSLDs) in a wide uniform ultra-high dose rate electron beam and demonstrate the potential use of TLDs and OSLDs to correct the ion recombination in air-filled ionization chambers. This study avoids previously reported complications related to the field size and homogeneity. Approach. Two types of OSLDs (BeO and Al 2 O 3 :C) and three types of TLDs (LiF:Mg,Ti, LiF:Mg,Cu,P, CaF 2 :Tm) were irradiated simultaneously in a uniform 16 MeV electron beam generated by a clinically decommissioned C-Arm LINAC, modified to deliver doses per pulse between 8.3 × 10 −4 Gy and 1.255 Gy, corresponding to instantaneous dose rates between 2 × 10 2 Gy s −1 and 3 × 10 5 Gy s −1 . A prototype ultra-thin parallel plate ionization chamber was employed as reference detector. Main results. Reproducible results were achieved both at conventional (standard deviation of the data 2 O 3 :C OSLD was found to be the most precise detector, with a standard deviation of the data Significance. The dose rate independence of the investigated TLDs and OSLDs make them good candidates for dosimetry at ultra-high dose rates, at least up to 3 × 10 5 Gy s −1 . A dose rate independent method to measure the dose per pulse is proposed, which can be applied to characterize ultra-high dose rate electron beams and correct for ion recombination in ionization chambers.
- Open Access
- 12 September 2023
- Published by Elsevier in Radiation Measurements
- Vol. 168
Testing the S / S R procedure using TLDs and OSLDs and a lexsyg smart automated reader for precise dosimetry
- 12 September 2023
- Published by Elsevier in Radiation Measurements
- Vol. 168
Open AccessTesting the S / S R procedure using TLDs and OSLDs and a lexsyg smart automated reader for precise dosimetry
- Open Access
- 11 July 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (14) , 145007
Investigation of TL and OSL detectors in ultra-high dose rate electron beams
Objective. This work aims at investigating the response of various thermally stimulated luminescence detectors (TLDs) and optically stimulated luminescence detectors (OSLDs) for dosimetry of ultra-high dose rate electron beams. The study was driven by the challenges of dosimetry at ultra-high dose rates and the importance of dosimetry for FLASH radiotherapy and radiobiology experiments. Approach. Three types of TLDs (LiF:Mg,Ti; LiF:Mg,Cu,P; CaF 2 :Tm) and one type of OSLD (Al 2 O 3 :C) were irradiated in a 15 MeV electron beam with instantaneous dose rates in the (1–324) kGy s −1 range. Reference dosimetry was carried out with an integrating current transformer, which was calibrated in absorbed dose to water against a reference ionization chamber. Additionally, dose rate independent BeO OSLDs were employed as a reference. Beam non-uniformity was addressed using a matrix of TLDs/OSLDs. Main results. The investigated TLDs were shown to be dose rate independent within the experimental uncertainties, which take into account the uncertainty of the dosimetry protocol and the irradiation uncertainty. The relative deviation between the TLDs and the reference dose was lower than 4 % for all dose rates. A decreasing response with the dose rate was observed for Al 2 O 3 :C OSLDs, but still within 10 % from the reference dose. Significance. The precision of the investigated luminescence detectors make them suitable for dosimetry of ultra-high dose rate electron beams. Specifically, the dose rate independence of the TLDs can support the investigation of the beam uniformity as a function of the dose rate, which is one of the challenges of the employed beam. Al 2 O 3 :C OSLDs provided high precision measurements, but the decreasing response with the dose rate needs to be confirmed by additional experiments.
- 11 July 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (14) , 145007
Open AccessInvestigation of TL and OSL detectors in ultra-high dose rate electron beams
Objective. This work aims at investigating the response of various thermally stimulated luminescence detectors (TLDs) and optically stimulated luminescence detectors (OSLDs) for dosimetry of ultra-high dose rate electron beams. The study was driven by the challenges of dosimetry at ultra-high dose rates and the importance of dosimetry for FLASH radiotherapy and radiobiology experiments. Approach. Three types of TLDs (LiF:Mg,Ti; LiF:Mg,Cu,P; CaF 2 :Tm) and one type of OSLD (Al 2 O 3 :C) were irradiated in a 15 MeV electron beam with instantaneous dose rates in the (1–324) kGy s −1 range. Reference dosimetry was carried out with an integrating current transformer, which was calibrated in absorbed dose to water against a reference ionization chamber. Additionally, dose rate independent BeO OSLDs were employed as a reference. Beam non-uniformity was addressed using a matrix of TLDs/OSLDs. Main results. The investigated TLDs were shown to be dose rate independent within the experimental uncertainties, which take into account the uncertainty of the dosimetry protocol and the irradiation uncertainty. The relative deviation between the TLDs and the reference dose was lower than 4 % for all dose rates. A decreasing response with the dose rate was observed for Al 2 O 3 :C OSLDs, but still within 10 % from the reference dose. Significance. The precision of the investigated luminescence detectors make them suitable for dosimetry of ultra-high dose rate electron beams. Specifically, the dose rate independence of the TLDs can support the investigation of the beam uniformity as a function of the dose rate, which is one of the challenges of the employed beam. Al 2 O 3 :C OSLDs provided high precision measurements, but the decreasing response with the dose rate needs to be confirmed by additional experiments.
- Open Access
- 17 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 045017
Characterization of LiF:Mg,Ti thermoluminescence detectors in low-LET proton beams at ultra-high dose rates
Objective. This work aims at characterizing LiF:Mg,Ti thermoluminescence detectors (TLDs) for dosimetry of a 250 MeV proton beam delivered at ultra-high dose rates (UHDR). Possible dose rate effects in LiF:Mg,Ti, as well as its usability for dosimetry of narrow proton beams are investigated. Approach. LiF:Mg,Ti (TLD-100TM Microcubes, 1 mm × 1 mm × 1 mm) was packaged in matrices of 5 × 5 detectors. The center of each matrix was irradiated with single-spot low-LET (energy >244 MeV) proton beam in the (1–4500) Gy s−1 average dose rates range. A beam reconstruction procedure was applied to the detectors irradiated at the highest dose rate (Gaussian beam sigma Main results. The lateral beam spread obtained from the beam reconstruction agreed with the one derived from the radiochromic film measurements. No dose rates effects were observed in LiF:Mg,Ti for the investigated dose rates within 3% (k = 1). On average, the dose response of the TLDs agreed with the reference detectors within their uncertainties. The largest deviation (−5%) was measured at 4500 Gy s−1. Significance. The dose rate independence of LiF:Mg,Ti TLDs makes them suitable for dosimetry of UHDR proton beams. Additionally, the combination of a matrix of TLDs and the beam reconstruction can be applied to determine the beam profile of narrow proton beams.
- 17 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (4) , 045017
Open AccessCharacterization of LiF:Mg,Ti thermoluminescence detectors in low-LET proton beams at ultra-high dose rates
Objective. This work aims at characterizing LiF:Mg,Ti thermoluminescence detectors (TLDs) for dosimetry of a 250 MeV proton beam delivered at ultra-high dose rates (UHDR). Possible dose rate effects in LiF:Mg,Ti, as well as its usability for dosimetry of narrow proton beams are investigated. Approach. LiF:Mg,Ti (TLD-100TM Microcubes, 1 mm × 1 mm × 1 mm) was packaged in matrices of 5 × 5 detectors. The center of each matrix was irradiated with single-spot low-LET (energy >244 MeV) proton beam in the (1–4500) Gy s−1 average dose rates range. A beam reconstruction procedure was applied to the detectors irradiated at the highest dose rate (Gaussian beam sigma Main results. The lateral beam spread obtained from the beam reconstruction agreed with the one derived from the radiochromic film measurements. No dose rates effects were observed in LiF:Mg,Ti for the investigated dose rates within 3% (k = 1). On average, the dose response of the TLDs agreed with the reference detectors within their uncertainties. The largest deviation (−5%) was measured at 4500 Gy s−1. Significance. The dose rate independence of LiF:Mg,Ti TLDs makes them suitable for dosimetry of UHDR proton beams. Additionally, the combination of a matrix of TLDs and the beam reconstruction can be applied to determine the beam profile of narrow proton beams.