Ya Tu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ya Tu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Lei Zhang
Department of Prosthodontics Peking University School and Hospital of Stomatology; National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Laboratory for Digital and Material Technology of Stomatology, Beijing Key Laboratory of Digital Stomatology, Research Center of Engineering and Technology for Computerized Dentistry, Ministry of Health, NMPA Key Laboratory for Dental Materials Beijing China
5 shared publications- Qian Ding
Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology & Beijing Key Laboratory of Digital Stomatology & Research Center of Engineering and Technology for Computerized Dentistry Ministry of Health & NMPA Key Laboratory for Dental Materials, Beijing, PR China
4 shared publications Shimin Wang
Dental Technician, Denture Processing Center, Peking University School and Hospital of Stomatology, Beijing, PR China
2 shared publicationsTingting Pu
Denture Processing Center Peking University School and Hospital of Stomatology Beijing PR China
2 shared publicationsGuangpu Zhao
Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing, PR China
1 shared publicationJianzhang Liu
Department of Prosthodontics Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Laboratory for Digital and Material Technology of Stomatology Beijing China
1 shared publication
Latest Publications
- 5 August 2026
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (8) , 1211-1218
Effect of a digital bite registration method considering physiological tooth displacement on virtual occlusion: A self‐controlled clinical trial
Purpose: This study aimed to evaluate the virtual intercuspal occlusion constructed by the segmented tooth registration method, considering physiological tooth displacement and the conventional buccal bite registration method. Materials and Methods: Twenty‐nine participants received 29 full crowns on the first molars. Two weeks after delivering the crowns, the posterior regions (upper and lower jaws, U1 and L1) containing the buccal surface occluding in maximum intercuspal position (MIP) under habitual occlusal force were scanned using an intraoral scanner (IOS). Two bite registration methods were conducted: (1) segmenting U1 and L1 into a single tooth and registering to the buccal surface occluding in MIP, respectively (test group), and automatically registering U1 and L1 by the IOS (control group). For evaluation of two virtual intercuspal occlusions, the mean, minimum, and negative mean of interocclusal distance, and occlusal contact area were calculated and compared. The Wilcoxon test was applied to analyze the statistical differences ( α = 0.050). Results: In the test group, the interocclusal distance for the second premolars, crowns on first molar, and second molars were as follows: the minimum interocclusal distance ranged from ‐51.2 to 1.1 µm, the mean from 39.9 to 57.8 µm, and the negative mean from ‐23.4 to ‐10.0 µm. These interocclusal distances were significantly larger than those in the control group, which ranged from ‐136.2 to ‐79.1 µm; 14.3 to 27.9 µm; and ‐48.1 to ‐30.7 µm for the same three indicators, respectively ( p < 0.010). The occlusal contact areas for the crowns and adjacent teeth of the test group were significantly smaller than those of the control group, respectively ( p < 0.010). Moreover, the mean and negative mean of interocclusal distance had no significant differences between the crowns and second premolars. Conclusions: By considering physiological tooth displacement, the segmented tooth bite registration method can significantly increase the mean interocclusal distance and reduce occlusal contact areas, thereby correcting the virtual occlusal collisions.
- 5 August 2026
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (8) , 1211-1218
Effect of a digital bite registration method considering physiological tooth displacement on virtual occlusion: A self‐controlled clinical trial
Purpose: This study aimed to evaluate the virtual intercuspal occlusion constructed by the segmented tooth registration method, considering physiological tooth displacement and the conventional buccal bite registration method. Materials and Methods: Twenty‐nine participants received 29 full crowns on the first molars. Two weeks after delivering the crowns, the posterior regions (upper and lower jaws, U1 and L1) containing the buccal surface occluding in maximum intercuspal position (MIP) under habitual occlusal force were scanned using an intraoral scanner (IOS). Two bite registration methods were conducted: (1) segmenting U1 and L1 into a single tooth and registering to the buccal surface occluding in MIP, respectively (test group), and automatically registering U1 and L1 by the IOS (control group). For evaluation of two virtual intercuspal occlusions, the mean, minimum, and negative mean of interocclusal distance, and occlusal contact area were calculated and compared. The Wilcoxon test was applied to analyze the statistical differences ( α = 0.050). Results: In the test group, the interocclusal distance for the second premolars, crowns on first molar, and second molars were as follows: the minimum interocclusal distance ranged from ‐51.2 to 1.1 µm, the mean from 39.9 to 57.8 µm, and the negative mean from ‐23.4 to ‐10.0 µm. These interocclusal distances were significantly larger than those in the control group, which ranged from ‐136.2 to ‐79.1 µm; 14.3 to 27.9 µm; and ‐48.1 to ‐30.7 µm for the same three indicators, respectively ( p < 0.010). The occlusal contact areas for the crowns and adjacent teeth of the test group were significantly smaller than those of the control group, respectively ( p < 0.010). Moreover, the mean and negative mean of interocclusal distance had no significant differences between the crowns and second premolars. Conclusions: By considering physiological tooth displacement, the segmented tooth bite registration method can significantly increase the mean interocclusal distance and reduce occlusal contact areas, thereby correcting the virtual occlusal collisions.
- 1 July 2024
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (4) , 600-604
A digital technique for occlusal design of a posterior full crown based on physiological tooth displacement and occlusion of adjacent teeth
This article presents a digital technique to construct a virtual occlusion in the maximal intercuspal position (MIP), considering physiological tooth displacement and reducing intermesh penetrations between occlusal surfaces, in order to design more precise and accurate occlusal contacts of a posterior full crown.
- 1 July 2024
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (4) , 600-604
A digital technique for occlusal design of a posterior full crown based on physiological tooth displacement and occlusion of adjacent teeth
This article presents a digital technique to construct a virtual occlusion in the maximal intercuspal position (MIP), considering physiological tooth displacement and reducing intermesh penetrations between occlusal surfaces, in order to design more precise and accurate occlusal contacts of a posterior full crown.
- 25 October 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 134 (2) , 327-331
Digitally designed occlusion of an implant-supported crown considering physiological tooth displacement under occlusal loading
- 25 October 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 134 (2) , 327-331
Digitally designed occlusion of an implant-supported crown considering physiological tooth displacement under occlusal loading
- 25 July 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 133 (5) , 1260-1267
Assessment of physiological posterior-tooth displacement under habitual occlusal force by intraoral scanning using implant-supported crowns as the reference
- 25 July 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 133 (5) , 1260-1267
Assessment of physiological posterior-tooth displacement under habitual occlusal force by intraoral scanning using implant-supported crowns as the reference
- 5 February 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 34 (3) , 275-284
Effect of a novel interocclusal recording method on occlusal accuracy of implant‐supported fixed prostheses: A randomized clinical trial
Objectives: To investigate the effect of a novel interocclusal recording method on the occlusal accuracy of implant‐supported fixed prostheses for partially dentate patients with distal extension.Materials and Methods: Twenty patients with two or more adjacent teeth missing in the distal extension and scheduled to receive implant‐supported fixed prostheses were enrolled. Two interocclusal recording methods were used: placing polyvinyl siloxane (PVS) on the interocclusal recording caps (test), and placing PVS on healing abutments (control). The intraoral occlusal contacts in maximal intercuspal position (MIP) were compared with those in the mounted casts to calculate sensitivity and positive predictive value (PPV). Then, patients were randomly allocated into two groups to determine which interocclusal record would be used. The implant prostheses' evaluations mainly included occlusal adjustment height, volume, and time, occlusal contact score based on articulating paper examination. Paired‐samples t‐test, Mann–Whitney U test, and least squares regression analyzed the statistic differences.Results: The test method had higher sensitivity to detect intraoral occlusal contacts than the control method (p = .002), but similar PPV (p = .10). During the prostheses' evaluations, the occlusal adjustment height in the test group was significantly lower than that in the control group [99.4 (53.2, 134.2) vs. 159.0 (82.3, 247.8) μm, p = .03], while the occlusal contact score before adjustment was higher (p = .006). The groups had similar occlusal adjustment volume and time.Conclusions: The novel interocclusal recording method for implant‐supported fixed prostheses was more accurate and could reduce the occlusal adjustment.
- 5 February 2023
- Published by Wiley in Clinical Oral Implants Research
- Vol. 34 (3) , 275-284
Effect of a novel interocclusal recording method on occlusal accuracy of implant‐supported fixed prostheses: A randomized clinical trial
Objectives: To investigate the effect of a novel interocclusal recording method on the occlusal accuracy of implant‐supported fixed prostheses for partially dentate patients with distal extension.Materials and Methods: Twenty patients with two or more adjacent teeth missing in the distal extension and scheduled to receive implant‐supported fixed prostheses were enrolled. Two interocclusal recording methods were used: placing polyvinyl siloxane (PVS) on the interocclusal recording caps (test), and placing PVS on healing abutments (control). The intraoral occlusal contacts in maximal intercuspal position (MIP) were compared with those in the mounted casts to calculate sensitivity and positive predictive value (PPV). Then, patients were randomly allocated into two groups to determine which interocclusal record would be used. The implant prostheses' evaluations mainly included occlusal adjustment height, volume, and time, occlusal contact score based on articulating paper examination. Paired‐samples t‐test, Mann–Whitney U test, and least squares regression analyzed the statistic differences.Results: The test method had higher sensitivity to detect intraoral occlusal contacts than the control method (p = .002), but similar PPV (p = .10). During the prostheses' evaluations, the occlusal adjustment height in the test group was significantly lower than that in the control group [99.4 (53.2, 134.2) vs. 159.0 (82.3, 247.8) μm, p = .03], while the occlusal contact score before adjustment was higher (p = .006). The groups had similar occlusal adjustment volume and time.Conclusions: The novel interocclusal recording method for implant‐supported fixed prostheses was more accurate and could reduce the occlusal adjustment.