MSMiloš Selaković

Miloš Selaković

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Miloš Selaković has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    General-Purpose Algorithm for Baseline Correction Based on Inscribed Polynomials

    by Miloš Selaković, Renato Zenobi, Lukas Emmenegger, Mihajlo Cekić, BélA Tuzson

    Accurate and reliable identification and removal of baseline or systematic drifts has a decisive impact on quantitative analysis. We introduce a robust signal-preserving baseline estimation method using a constrained low-order polynomial approximation with an area-maximization objective. We formulate a mathematical framework and prove the existence and uniqueness of this polynomial under bounded-noise and regularity assumptions, and derive a constructive algorithm. Practical guidance is provided for selecting the polynomial degree a priori, and the noise tolerance is estimated directly from the data. Across representative chromatographic, spectroscopic, and electrochemical datasets, the method yields smooth, stable baselines and robust quantification without manual tuning of parameters. For chromatographic and spectroscopic data, it produces highly linear calibration plots (R2 > 0.999) with near-zero intercepts. For electrochemical traces with exponential-like backgrounds, it achieves consistent baseline corrections with only minor, well characterized artifacts. Compared to AirPLS (adaptive iteratively reweighted penalized least squares), the approach is parameter-light, signal preserving, and resilient to baseline curvature and outliers. It offers a simple, mathematically principled, and broadly applicable solution for automated baseline correction, making it well-suited for high-throughput and unsupervised analytical workflows.

  • Open Access

    Rapid Determination of Multi-VOCs in Breath using Vernier Quantum-Cascade Laser Spectroscopy

    by Milos Selakovic, Renato Zenobi, Lukas Emmenegger, Srdjan Micic, Alexander Moeller, Bela Tuzson

    We present a fully integrated, portable spectrometer based on Vernier-tuned quantum-cascade laser, developed for real-time measurement of volatile organic compounds (VOCs) in exhaled breath. A dedicated overflow-based breath-inlet interface provides stable and reproducible sampling by minimizing gas-exchange delays and preventing water condensation, while enabling automated segmentation of diagnostically relevant phases of individual exhalations either through flow- or CO 2 -triggering. To address quantification in congested mid-infrared spectra, we developed an automated sliding-window selection algorithm based on a hierarchical search strategy. The algorithm identifies narrow spectral regions with high specificity for a target analyte and low contributions from spectral interferences, thereby reducing dependence on subjective spectral-window selection and enabling robust and reproducible procedure for quantification. The analytical workflow was validated through controlled spiking experiments with limits of quantification ranging from 6 to 200 ppb for the VOCs investigated. Real-time breath measurements in individual volunteers are presented as proof-of-concept demonstrations of the platform’s ability to monitor different breath VOCs and their temporal dynamics in complex gas matrices. The measurements include a biphasic postprandial methanol response following fruit consumption and prolonged washout of the asthma-inhaler propellant 1,1,1,2-tetrafluoroethane (HFC-134a). The high temporal resolution additionally resolves intra-breath VOC profiles, providing information on differences in the temporal behavior of endogenous and exogenously induced contributions. Overall, the combination of Vernier-QCL spectroscopy with automated spectral-window selection and controlled breath sampling provides a compact and robust approach to time-resolved multi-VOC quantification in human breath and establishes a basis for further development toward clinical breath-research applications.

  • Open Access

    The Impact of Molecular Symmetry and Rigidity on the Selective Analysis of VOCs by Mid-IR Laser Spectroscopy

    by Miloš Selaković, Renato Zenobi, Lukas Emmenegger, Béla Tuzson

    This study highlights the potential of mid-infrared laser absorption spectroscopy (LAS) for analyzing volatile organic compounds (VOCs) in the gas phase. Using a Vernier-type quantum cascade laser (QCL) in the 9-10 μm spectral region, over 40 different VOCs were systematically investigated with a spectral resolution better than 0.005 cm-1. It was found that many VOCs, even with more than six heavy atoms, can exhibit significant spectral features at ambient temperature and pressures above 10 mbar, i.e., at conditions well suited for routine analysis. Our observations suggest that in addition to molecular weight and number of atoms, molecular rigidity and symmetry have a decisive impact on the spectral feature content. The high spectral feature content observed in rigid molecules is related to their small number of conformers, while higher molecular symmetry results in fewer nondegenerate vibrational modes, principal rotational axes with different moments of inertia, and a reduced number of nonidentical conformers. Overall, this leads to distinct spectral features that enable the selective and sensitive detection of large VOCs by high-resolution LAS.


  • Open Access

    Rapid Detection of Volatile Organic Compounds by Switch–Scan Tuning of Vernier Quantum-Cascade Lasers

    by Raphael Brechbühler, Miloš Selaković, Philipp Scheidegger, Herbert Looser, André Kupferschmid, Stéphane Blaser, Jérémy Butet, Lukas Emmenegger, Béla Tuzson

    Volatile organic compounds (VOCs) exhibit typically broad and mutually overlapping ro-vibrational absorption fingerprints. This complexity has so far limited the applicability of laser-based spectroscopy for VOC measurements in complex gas matrices. Here, we exploit a Vernier-type quantum-cascade laser (QCL) as an electrically tunable multiwavelength source for selective and sensitive VOC analysis. This emerging class of lasers provides access to several spectral windows by discrete Vernier tuning ("switching") and continuous coverage within these windows ("scanning"). We present a versatile driving technique that efficiently combines the two tuning mechanisms. Applied to our Vernier QCL, it enables the rapid acquisition (within 360 ms) of high-resolution spectra from six individual spectral windows, distributed over a wide range from 1063 to 1102 cm-1. Gaining access to the broad absorption envelopes of VOCs at multiple frequencies, along with their superimposed fine structure, which are especially pronounced at a reduced sample pressure, offers completely new opportunities in VOC analysis. The potential of this approach is assessed in a direct-laser-absorption setup with acetaldehyde, ethanol, and methanol as benchmark compounds with significant spectral overlaps. A measurement precision of 1-10 ppb is obtained after integration for 10 s at amount fractions below 10 ppm, and excellent linearity is found over at least 3 orders of magnitude. Combined with our dedicated spectral fitting algorithm, we demonstrate highly selective multicompound analyses with less than 3.5% relative expanded uncertainty, even in the presence of a 40× excess of an interfering compound with complete spectral overlap.