Grigory Gurin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Grigory Gurin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
A.V. Tarasov
Rudgeofizika, ul. Aerodromnaya 8A, St. Petersburg, 197110, Russia
1 shared publication- Andreas Kemna
Geophysics Section, Institute of Geosciences, University of Bonn , D-53115 Bonn
1 shared publication - Joost Hase
Geophysics Section, Institute of Geosciences, University of Bonn , Meckenheimer Allee 176, D-53115 Bonn
1 shared publication - Konstantin S. Titov
Moscow Multidisciplinary Scientific and Clinical Center, Moscow Healthcare Department; RUDN University
1 shared publication Konstantin Titov
Department of Geophysics, Institute of Earth Sciences, St.-Petersburg State University , 7/9 Universitetskaya Naberezhnaya St.-Petersburg 199034 , Russia
1 shared publicationК.V. Titov
St. Petersburg State University, Universitetskaya nab. 7/9, St. Petersburg, 199034, Russia
1 shared publication
Latest Publications
- Open Access
Conversion of Induced Polarization Data and Their Uncertainty from Time Domain to Frequency Domain Using Debye Decomposition
The time-domain (TD) induced polarization (IP) method is used as an extension of direct current (DC) resistivity measurements to capture information on the ability of the subsurface to develop electrical polarization. In the TD, the transient voltage decay is measured after the termination of the current injection. To invert tomographic TD IP data sets into frequency-domain (FD) models of complex electrical resistivity, a suitable approach for converting TD IP transients and their corresponding uncertainties into the FD is essential. To apply existing FD inversion algorithms to TD IP measurements, a conversion scheme must transform the measured decay curves into FD impedances and also propagate the corresponding measurement uncertainty from the TD to the FD. Here, we present such an approach based on a Debye decomposition (DD) of the decay curve into a relaxation-time distribution and the calculation of the equivalent spectrum. The corresponding FD data error can be obtained by applying error propagation through all of these steps. To accomplish the DD we implement a non-linear Gauss–Newton inversion scheme. We test the conversion scheme in a synthetic study and demonstrate its application to field data on a tomographic TD IP data set measured on the Maletoyvaemskoie ore field (Kamchatka, Russia). The proposed conversion scheme yields accurate impedance data for relaxation processes, which are resolved by the TD measurements. The error propagation scheme provides a reasonable FD uncertainty estimate, as confirmed by a Monte Carlo analysis of the underlying parameter distributions.
Open AccessConversion of Induced Polarization Data and Their Uncertainty from Time Domain to Frequency Domain Using Debye Decomposition
The time-domain (TD) induced polarization (IP) method is used as an extension of direct current (DC) resistivity measurements to capture information on the ability of the subsurface to develop electrical polarization. In the TD, the transient voltage decay is measured after the termination of the current injection. To invert tomographic TD IP data sets into frequency-domain (FD) models of complex electrical resistivity, a suitable approach for converting TD IP transients and their corresponding uncertainties into the FD is essential. To apply existing FD inversion algorithms to TD IP measurements, a conversion scheme must transform the measured decay curves into FD impedances and also propagate the corresponding measurement uncertainty from the TD to the FD. Here, we present such an approach based on a Debye decomposition (DD) of the decay curve into a relaxation-time distribution and the calculation of the equivalent spectrum. The corresponding FD data error can be obtained by applying error propagation through all of these steps. To accomplish the DD we implement a non-linear Gauss–Newton inversion scheme. We test the conversion scheme in a synthetic study and demonstrate its application to field data on a tomographic TD IP data set measured on the Maletoyvaemskoie ore field (Kamchatka, Russia). The proposed conversion scheme yields accurate impedance data for relaxation processes, which are resolved by the TD measurements. The error propagation scheme provides a reasonable FD uncertainty estimate, as confirmed by a Monte Carlo analysis of the underlying parameter distributions.
- 24 April 2023
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 234 (3) , 1722-1734
Spectral induced polarization of rocks with electronically conductive inclusions: a semi-empirical capillary model
SUMMARY: Induced polarization (IP) method is widely used in different applications including mining geology, hydrogeology, contaminant hydrology, geodynamics and geothermal research. For this reason, petrophysical investigations of IP parameters present an increased interest. Last decades IP behaviour of rocks and sediments containing metallic particles (MP) was extensively studied. Petrophysical investigations were performed mostly with synthetic granular models presented mixtures of sands and MP. In this paper, for the first time, we present IP data measured on a synthetic capillary model. The model made of Plexiglas contains a bundle of capillaries: some active (i.e. blocked by MP), others passive (open). In the experiments, we varied (i) the volumetric content of MP (ii) the water electrical resistivity, (iii) the model porosity and (iv) the MP resistance. We found that the chargeability primarily depends on the ratio of the active to total surface of the pore cross-sections. Consequently, when the model contains only one active pore, and no passive pores, the chargeability is equal to 100 per cent. This is the case even if the volumetric content of MP is very small. This behaviour of the capillary model is contrary to that of sand-MP mixture where the chargeability is approximately proportional to the volumetric MP content. We also found that the relaxation time of the capillary model depends on the bulk resistivity, the MP resistivity and the specific capacitance of the electrical double layer at the ‘MP–pore water’ interface. We explain the experimental data based on a new semi-empirical model. The model presents an extension of Pelton's model with explicit consideration of electrical and structural parameters of the capillaries.
- 24 April 2023
- Published by Oxford University Press (OUP) in Geophysical Journal International
- Vol. 234 (3) , 1722-1734
Spectral induced polarization of rocks with electronically conductive inclusions: a semi-empirical capillary model
SUMMARY: Induced polarization (IP) method is widely used in different applications including mining geology, hydrogeology, contaminant hydrology, geodynamics and geothermal research. For this reason, petrophysical investigations of IP parameters present an increased interest. Last decades IP behaviour of rocks and sediments containing metallic particles (MP) was extensively studied. Petrophysical investigations were performed mostly with synthetic granular models presented mixtures of sands and MP. In this paper, for the first time, we present IP data measured on a synthetic capillary model. The model made of Plexiglas contains a bundle of capillaries: some active (i.e. blocked by MP), others passive (open). In the experiments, we varied (i) the volumetric content of MP (ii) the water electrical resistivity, (iii) the model porosity and (iv) the MP resistance. We found that the chargeability primarily depends on the ratio of the active to total surface of the pore cross-sections. Consequently, when the model contains only one active pore, and no passive pores, the chargeability is equal to 100 per cent. This is the case even if the volumetric content of MP is very small. This behaviour of the capillary model is contrary to that of sand-MP mixture where the chargeability is approximately proportional to the volumetric MP content. We also found that the relaxation time of the capillary model depends on the bulk resistivity, the MP resistivity and the specific capacitance of the electrical double layer at the ‘MP–pore water’ interface. We explain the experimental data based on a new semi-empirical model. The model presents an extension of Pelton's model with explicit consideration of electrical and structural parameters of the capillaries.
- 1 March 2023
- Published by GeoScienceWorld in Russian Geology and Geophysics
- Vol. 64 (3) , 348-356
Analysis of Transient Characteristics of Induced Polarization in Innovative Mineral Exploration Solutions (from Case Studies of Gold Deposits)
—The paper discusses current state of the spectral approach to analysis of induced polarization (IP), its possibilities and limitations, along with directions for the method development. Reviewed are the main methods and approaches for estimation of spectral IP parameters and their specific features. Our practical experiments have shown the advantages of analysis of transient IP characteristics over standard approaches to the IP data analysis and processing. Results of the standard and spectral approaches application to analysis of IP data when solving mineral exploration problems at the Maletoyvayam gold deposit (Kamchatka Peninsula) and the Yasnoe gold occurrence (Taimyr Peninsula) are compared. Here, we demonstrate that low efficiency of works is erroneously regarded as one of the main factors hindering a broad adoption of the spectral IP method in mineral exploration activities. Rather, it is a lack of automated techniques for analysis of transient IP characteristics. We propose a new approach to spectral analysis of IP data, based on the algorithms for image recognition of a reference object, and describe pioneering efforts of its practical application.
- 1 March 2023
- Published by GeoScienceWorld in Russian Geology and Geophysics
- Vol. 64 (3) , 348-356
Analysis of Transient Characteristics of Induced Polarization in Innovative Mineral Exploration Solutions (from Case Studies of Gold Deposits)
—The paper discusses current state of the spectral approach to analysis of induced polarization (IP), its possibilities and limitations, along with directions for the method development. Reviewed are the main methods and approaches for estimation of spectral IP parameters and their specific features. Our practical experiments have shown the advantages of analysis of transient IP characteristics over standard approaches to the IP data analysis and processing. Results of the standard and spectral approaches application to analysis of IP data when solving mineral exploration problems at the Maletoyvayam gold deposit (Kamchatka Peninsula) and the Yasnoe gold occurrence (Taimyr Peninsula) are compared. Here, we demonstrate that low efficiency of works is erroneously regarded as one of the main factors hindering a broad adoption of the spectral IP method in mineral exploration activities. Rather, it is a lack of automated techniques for analysis of transient IP characteristics. We propose a new approach to spectral analysis of IP data, based on the algorithms for image recognition of a reference object, and describe pioneering efforts of its practical application.