DHDavid Hofman

David Hofman

*This is an algorithmically generated author record based on publicly available information.

David Hofman has a total of 114 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Elastic and Structural Anisotropy in Silica Thin Films for Gravitational-Wave Detectors

    by Brenda Bracco, Michele Magnozzi, Stefano Colace, Maurizio Canepa, Giulio Favaro, Marco Bazzan, Massimo Granata, David Hofman, Alessandro Di Michele, Laura Silenzi, et al.

    The thermal noise of mirror coatings for gravitational-wave detectors critically depends on the elastic properties of the constituent materials. Data analyses and theoretical models typically assume each material is homogeneous and isotropic, but isotropy has never been explicitly verified. Using Brillouin light scattering (BLS), we demonstrate that ion-beam-sputtered SiO 2 —a material still viable for future mirror coatings—exhibits cylindrical elastic symmetry, with in-plane isotropy but a notable 6% compressive anisotropy along the film normal. This anisotropy remains unchanged after the postdeposition heat treatment currently used in ground-based detectors ( 500 ° C , 10 h) but is nearly eliminated at 900 ° C . Infrared reflectivity experiments support these findings by directly revealing heterogeneities in the distribution of bridging and nonbridging oxygen structures along the growth axis. While BLS measures the real part of the elastic constants at gigahertz frequencies, the data reveal negligible contributions from mechanical relaxations in the kilohertz to gigahertz range, making BLS a valid substitute for low-frequency properties obtained from standard anisotropy-insensitive techniques. Our results highlight that restoring isotropy through heat treatment—by softening the material, enabling more than 7% out-of-plane expansion, and smoothing out structural heterogeneities—may play a key role in reducing thermal noise. This proof-of-concept study extends beyond silica, providing critical insights for the design of future coatings.

  • Étude et installation d'un contrôle optique large-bande dans une machine de dépôt sous vide de grandes dimensions

    by David Hofman

    Les optiques utilisées pour les expérimentations utilisant la lumière blanche ou des lasers, sont généralement traitées afin de fonctionnaliser optiquement la surface pour, par exemple accroître leur faculté à réfléchir la lumière ou au contraire à la transmettre. Ceci est fait au moyen de machines de dépôt sous vide dans lesquelles différentes techniques de dépôt peuvent être utilisées. Dans tous les cas, de la matière est envoyée sur la surface de l'optique à traiter : des couches minces de différents matériaux sont alternativement déposées à leur surface. Cette amélioration des fonctions optiques exploite l'interférence des rayons lumineux qui sont réfléchis ou transmis par ces couches minces. Mais pour que le traitement soit efficace, il est nécessaire que les épaisseurs de chaque couche déposées respectent un schéma défini à l'avance : le design optique, il s'agit du plan de l'empilement des couches à déposer et de leurs épaisseurs théoriques.Différentes techniques de contrôle in-situ de l'épaisseur des couches minces existent. L'une d'elles, le contrôle quartz, est une technique de contrôle largement répandue pour sa simplicité de mise en œuvre mais possède une précision limitée à seulement quelques pourcents. Le sujet de cette thèse porte sur le développement et l'installation dans une machine de dépôt, prévue pour de grandes optiques, d'un système de contrôle basé sur l'analyse spectrale d'une lumière réfléchie par l'optique en cours de dépôt. Il s'agit d'un contrôle optique large-bande, technique mise en place dans la grande machine de dépôt du laboratoire afin de remplacer le contrôle quartz.Nous commencerons cette thèse par un aperçu des différentes techniques de dépôts utilisées au laboratoire puis des techniques de contrôle d'épaisseur les plus répandues dans le domaine des couches minces. Ensuite, nous continuerons sur le design et l'installation du système optique qui permet d'effectuer la mesure des couches en cours de dépôt. Enfin, nous monterons que les spécifications fixées sur les empilements de couches minces ont été atteintes avec précision et répétabilité

  • Open Access

    Optical Properties at 1550 nm of Ion-Beam Sputtered Silicon Nitride Thin Films

    by Diksha, Alex Amato, Gianluigi Maggioni, Christophe Michel, David Hofman, Massimo Granata, Jessica Steinlechner

    Coating Brownian thermal noise is a major limitation to the sensitivity of gravitational-wave detectors. To reduce it, future detectors are planned to operate at cryogenic temperatures. This implies a change of their mirror coating materials and the use of a longer laser wavelength, such as 1550 nm. A stack of amorphous silicon and silicon nitride layers has previously been proposed as a promising combination of low- and high-refractive index materials to realize low-noise highly-reflective coatings. An essential step towards such coatings is the production of both materials via ion-beam sputtering. In this paper, for the first time, we present a study of the optical properties at 1550 nm of silicon nitride thin films deposited via ion beam sputtering. The refractive index and optical absorption as a function of post-deposition heat treatment temperature are investigated using a spectrophotometer and a photo-thermal common-path interferometer. Finally, we discuss the prospect of combining this material with amorphous silicon.


  • Development of ion-beam sputtered silicon nitride thin films for low-noise mirror coatings of gravitational-wave detectors

    by A. Amato, M. Bazzan, G. Cagnoli, M. Canepa, M. Coulon, J. Degallaix, N. Demos, A. Di Michele, M. Evans, F. Fabrizi, et al.


  • Comparison of arm cavity optical losses for the two wavelengths of the Einstein telescope gravitational wave detector

    by Maxime Le Jean, Jerome Degallaix, David Hofman, Laurent Pinard, Danièle Forest, Massimo Granata, Christophe Michel, Jessica Steinlechner, Claude Amra, Michel Lequime, et al.

    A new generation of gravitational wave detectors is currently being designed with the likely use of a different laser wavelength compared to current instruments. The estimation of the optical losses for this new wavelength is particularly relevant to derive the detector sensitivity and also to anticipate the optical performances of future instruments. In this article, we measured the absorption and angle-resolved scattering of several mirror samples in order to compare optical losses at a wavelength of 1064 and 1550 nm. In addition, we have carried out simulations of the Einstein Telescope arm cavities at 1064 and 1550 nm taking into account losses due to surface low-spatial frequency flatness. Our results suggest that optical losses as measured at 1064 nm are about twice as large as those at 1550 nm as predicted with a simple model.

  • Open Access

    Optical characterization of high performance mirrors based on cavity ringdown time measurements with 6 degrees of freedom mirror positioning

    by N. Gutierrez, J. Degallaix, D. Hofman, C. Michel, L. Pinard, J. Morville, R. Battesti, G. Cagnoli

    An instrument capable of measuring optical losses, transmission, and the radius of curvature of high reflectivity mirrors is presented. The measurement setup consists of two remote controlled hexapod systems with 6 degrees of freedom placed inside a vacuum enclosure. Mirror loss measurements are performed via the cavity ring-down time method using a linear resonant two-mirror Fabry–Perot cavity configuration. The use of high-precision positioning systems enables cavity loss mapping by transversely scanning the position of the cavity end mirror. Mirror surfaces of up to 30 mm in diameter can be scanned, and the cavity length can be tuned by 120 mm.


  • Open Access

    Determination of stress in thin films using micro-machined buckled membranes

    by C. Malhaire, M. Granata, D. Hofman, A. Amato, V. Martinez, G. Cagnoli, A. Lemaitre, N. Shcheblanov

    In this work, optical profilometry and finite-element simulations are applied on buckled micromachined membranes for the stress analysis of ion-beam-sputtered Ta2O5 and SiO2 thin films. Layers with different thicknesses are grown on silicon substrates, and then several membranes with different geometries are manufactured with standard microsystem technologies; due to a high level of films’ compressive stress, buckled membranes are obtained. Thermally grown silica membranes are also produced for comparison. The residual stress values are determined by comparing the measured and simulated deflections of the membranes. The average stress state of Ta2O5 thin films is found to be −209 MPa. The SiO2 thin films are in a higher compressive stress state whose average value is −576 MPa. For comparison, the average stress in thermal SiO2 thin layers grown at 1130°C is found equal to −321 MPa, in good agreement with the literature.


  • Recent advances toward mesoscopic quantum optomechanics

    by M. Croquette, S. Deléglise, T. Kawasaki, K. Komori, M. Kuribayashi, A. Lartaux-Vollard, N. Matsumoto, Y. Michimura, M. Andia, N. Aritomi, et al.

    We present a number of approaches, currently in experimental development in our research groups, toward the general problem of macroscopic quantum mechanics, i.e., manifestations of quantum noise and quantum fluctations with macroscopic (engineered and microfabricated by man) mechanical systems. Discussed experiments include a pendulum, a torsion pendulum, a ng-scale phononic-crystal silicon nitride membrane, a μ g-scale quartz resonator, and mg-scale mirrors for optical levitation. We also discuss relevant applications to quantum thermometry with optomechanical systems and the use of squeezed light to probe displacements beyond conventional quantum limits.


  • Open Access

    Argon and Other Defects in Amorphous SiO2 Coatings for Gravitational-Wave Detectors

    by Annalisa Paolone, Ernesto Placidi, Elena Stellino, Maria Grazia Betti, Ettore Majorana, Carlo Mariani, Alessandro Nucara, Oriele Palumbo, Paolo Postorino, Marco Sbroscia, et al.

    Amorphous SiO2 thin films are one of the two components of the highly reflective mirror coatings of gravitational-wave detectors. For this study, layers of amorphous SiO2 on crystalline Si substrates were produced by ion-beam sputtering (IBS), using accelerated neutralized argon ions as sputtering particles, as is the case for the actual mirror coatings of gravitational-wave detectors. The aim of this study is to investigate the possible presence of various defects in the materials in order to improve the coating quality. We provide evidence that, due to the synthesis method, about 0.2 wt.% of Ar is present in the coatings, and it can be released by means of thermal treatments, starting around 400 °C. The time and temperature to obtain the total release of Ar increases with the coating thickness; for a thickness of 100 nm, all argon is released below 600 °C, while an isotherm of one hour at 900 °C is necessary for a coating 5 μm thick. Besides the Ar atoms left from the synthesis, other defects, such as Si clusters and silicon dangling bonds, are present in the coatings. The concentration of both of them is strongly reduced by thermal treatments either in vacuum or in air. The overall thickness of the coating is slightly increased after thermal treatments, as witnessed by the change of the period of interference fringes.


  • Photometric calibration of an in situ broadband optical thickness monitoring of thin films in a large vacuum chamber

    by David Hofman, Benoit Sassolas, Christophe Michel, Laurent Balzarini, Laurent Pinard, Julien Teillon, Bertrand David, Bernard Lagrange, Eleonore Barthelemy-Mazot, Gianpietro Cagnoli

    To improve the in situ monitoring of thin films at the Laboratoire des Matériaux Avancés, a broadband optical monitoring of the coated thin films was developed and installed in the biggest ion-beam sputtering machine in the world. Due to the configuration of the coating machine and the chamber strain under vacuum, a standard calibration procedure is impossible and a double-beam optical system is not suitable. A novel theoretical and practical solution to calibrate the measurements was found and is described in this paper. Some relevant results achieved thanks to this technique are discussed as well.