Yue Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yue Jin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Long Huang
Guilin Architectural and Planning Design Group Co., Ltd., Guilin, China
1 shared publicationNing Zhang
Guangxi Key Laboratory of New Energy and Building Energy Saving, Guilin University of Technology, Guilin, China
1 shared publication- Xiao Wang
College of Tourism & Landscape Architecture, Guilin University of Technology, Guilin 541004, China
1 shared publication Xuan Luo
Guangxi Key Laboratory of New Energy and Building Energy Saving, Guilin University of Technology, Guilin, China
1 shared publication- Zhicheng Wu
College of Civil Engineering and Architecture, Guilin University of Technology, Guilin, China
1 shared publication
Latest Publications
- 22 February 2023
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 29 (3) , 251-267
Appraisal of indoor environment quality (IEQ) in nearly Zero energy Building (nZEB): A literature review
Nearly zero energy buildings (nZEB) are considered a key measure to reduce energy consumption in buildings. However, there is growing evidence that nZEB design strategies may impact indoor environmental quality (IEQ). Most of the current research on nZEB has focused on the energy efficiency and cost-effectiveness of nZEB, with less research on the IEQ of nZEB. This literature reviewed 25 case studies on IEQ assessment to determine the actual IEQ performance in nZEB and the impact of design strategies on IEQ. The results showed that all four parameters of IEQ performance assessment have yet to be included in the scope of IEQ assessment. In addition to physical parameter measurements and criteria, subjective measurements should be the primary determinant of IEQ. Moreover, the analysis shows that overheating, poor air quality, thermal discomfort, and Sick Building Syndrome (SBS) are common IEQ risk factors reported. At the same time, the building envelope, HVAC system, and control system are the main factors contributing to the increase in IEQ risk factors. This review will provide practical reference values and recommendations for building professionals in future studies.
- 22 February 2023
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 29 (3) , 251-267
Appraisal of indoor environment quality (IEQ) in nearly Zero energy Building (nZEB): A literature review
Nearly zero energy buildings (nZEB) are considered a key measure to reduce energy consumption in buildings. However, there is growing evidence that nZEB design strategies may impact indoor environmental quality (IEQ). Most of the current research on nZEB has focused on the energy efficiency and cost-effectiveness of nZEB, with less research on the IEQ of nZEB. This literature reviewed 25 case studies on IEQ assessment to determine the actual IEQ performance in nZEB and the impact of design strategies on IEQ. The results showed that all four parameters of IEQ performance assessment have yet to be included in the scope of IEQ assessment. In addition to physical parameter measurements and criteria, subjective measurements should be the primary determinant of IEQ. Moreover, the analysis shows that overheating, poor air quality, thermal discomfort, and Sick Building Syndrome (SBS) are common IEQ risk factors reported. At the same time, the building envelope, HVAC system, and control system are the main factors contributing to the increase in IEQ risk factors. This review will provide practical reference values and recommendations for building professionals in future studies.