Alain J. Kassab
Alain J. Kassab has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Divo
Department of Mechanical Engineering, Embry-Riddle Aeronautical University, Daytona Beach, FL 32114, USA
2 shared publications Andrew D Iams
Materials Science & Engineering, The Pennsylvania State University , University Park, PA 16802 , USA
1 shared publication- Charles T. Price
International Hip Dysplasia Institute, Orlando, FL, USA
1 shared publication D.W. Nicholson
Mechanical Materials and Aerospace Engineering, University of Central Florida, Orlando, FL 32816-2450, USA
1 shared publicationF. Moslehy
University of Central Florida,Department of Mechanical and Aerospace Engineering,Orlando,Florida,USA
1 shared publicationH.A. Mansy
University of Central Florida,Department of Mechanical and Aerospace Engineering,Orlando,Florida,USA
1 shared publication
Latest Publications
- Open Access
- 9 January 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 145-154
Cryo-EXLO Manipulation of FIB Specimens for Cryo-TEM
This work describes cryogenic ex situ lift out (cryo-EXLO) of cryogenic focused ion beam (cryo-FIB) thinned specimens for analysis by cryogenic transmission electron microscopy (cryo-TEM). Steps and apparatus necessary for cryo-EXLO are described. Methods designed to limit ice contamination include use of an anti-frost lid, a vacuum transfer assembly, and a cryostat. Cryo-EXLO is performed in a cryostat with the cryo-shuttle holder positioned in the cryogenic vapor phase above the surface of liquid N2 (LN2) using an EXLO manipulation station installed inside a glove box maintained at < 10% relative humidity and inert (e.g., N2 gas) conditions. Thermal modeling shows that a cryo-EXLO specimen will remain vitreous within its FIB trench indefinitely while LN2 is continuously supplied. Once the LN2 is cut off, modeling shows that the EXLO specimen will remain vitreous for over 4 min, allowing sufficient time for the cryo-transfer steps which take only seconds to perform. Cryo-EXLO was applied successfully to cryo-FIB-milled specimen preparation of a polymer sample and plunge-frozen yeast cells. Cryo-TEM of both the polymer and the yeast shows minimal ice contamination with the yeast specimen maintaining its vitreous phase, illustrating the potential of cryo-EXLO for cryo-FIB-EM of beam-sensitive, liquid, or biological materials.
- 9 January 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (1) , 145-154
Open AccessCryo-EXLO Manipulation of FIB Specimens for Cryo-TEM
This work describes cryogenic ex situ lift out (cryo-EXLO) of cryogenic focused ion beam (cryo-FIB) thinned specimens for analysis by cryogenic transmission electron microscopy (cryo-TEM). Steps and apparatus necessary for cryo-EXLO are described. Methods designed to limit ice contamination include use of an anti-frost lid, a vacuum transfer assembly, and a cryostat. Cryo-EXLO is performed in a cryostat with the cryo-shuttle holder positioned in the cryogenic vapor phase above the surface of liquid N2 (LN2) using an EXLO manipulation station installed inside a glove box maintained at < 10% relative humidity and inert (e.g., N2 gas) conditions. Thermal modeling shows that a cryo-EXLO specimen will remain vitreous within its FIB trench indefinitely while LN2 is continuously supplied. Once the LN2 is cut off, modeling shows that the EXLO specimen will remain vitreous for over 4 min, allowing sufficient time for the cryo-transfer steps which take only seconds to perform. Cryo-EXLO was applied successfully to cryo-FIB-milled specimen preparation of a polymer sample and plunge-frozen yeast cells. Cryo-TEM of both the polymer and the yeast shows minimal ice contamination with the yeast specimen maintaining its vitreous phase, illustrating the potential of cryo-EXLO for cryo-FIB-EM of beam-sensitive, liquid, or biological materials.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A System for Measuring Sound Transmission Through Joints
Sound transmission in the human body can be affected by the tissue composition along the sound path and surrounding structures. Therefore, acoustic transmission may correlate with pathologies involving structural changes. Previous studies utilized sound transmission to detect a variety of pulmonary, gastrointestinal, vascular, cardiac conditions, and developmental dysplasia of the hip (DDH) [1] [2] [3] [4] [5] [6] . The objective of this study is to design and test a reliable system capable of providing adequate acoustic stimulus, and simultaneously measure transmitted signals at multiple skin surface locations. The study objectives include determining: (1) the static load needed to reach a target SNR (>20 dB) at the measurement points and a target coherence (>0.8) between excitation and measurement points; (2) the exciter sensitivity to static load changes; and (3) the exciter input maximum power and corresponding acceleration. These results will help guide the choice of optimal exciter that: (1) can withstand sufficient static load (~500g), which would provide coupling to the bone to reach a target SNR and coherence; (2) has low sensitivity to load (low variability for a load change ~100 gm); (3) can provide sufficient acoustic excitation energy to maintain the target SNR and coherence; (4) be available at a reasonable cost (~<$500); (5) ensures patient comfort (with no subject discomfort reported for a contact area of ~ 2 cm 2 ).
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A System for Measuring Sound Transmission Through Joints
Sound transmission in the human body can be affected by the tissue composition along the sound path and surrounding structures. Therefore, acoustic transmission may correlate with pathologies involving structural changes. Previous studies utilized sound transmission to detect a variety of pulmonary, gastrointestinal, vascular, cardiac conditions, and developmental dysplasia of the hip (DDH) [1] [2] [3] [4] [5] [6] . The objective of this study is to design and test a reliable system capable of providing adequate acoustic stimulus, and simultaneously measure transmitted signals at multiple skin surface locations. The study objectives include determining: (1) the static load needed to reach a target SNR (>20 dB) at the measurement points and a target coherence (>0.8) between excitation and measurement points; (2) the exciter sensitivity to static load changes; and (3) the exciter input maximum power and corresponding acceleration. These results will help guide the choice of optimal exciter that: (1) can withstand sufficient static load (~500g), which would provide coupling to the bone to reach a target SNR and coherence; (2) has low sensitivity to load (low variability for a load change ~100 gm); (3) can provide sufficient acoustic excitation energy to maintain the target SNR and coherence; (4) be available at a reasonable cost (~<$500); (5) ensures patient comfort (with no subject discomfort reported for a contact area of ~ 2 cm 2 ).
- 1 December 2012
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 22 (6) , 800-808
Computational fluid dynamics in congenital heart disease
Computational fluid dynamics has been applied to the design, refinement, and assessment of surgical procedures and medical devices. This tool calculates flow patterns and pressure changes within a virtual model of the cardiovascular system. In the field of paediatric cardiac surgery, computational fluid dynamics is being used to elucidate the optimal approach to staged reconstruction of specific defects and study the haemodynamics of the resulting anatomical configurations after reconstructive or palliative surgery. In this paper, we review the techniques and principal findings of computational fluid dynamics studies as applied to a few representative forms of congenital heart disease.
- 1 December 2012
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 22 (6) , 800-808
Computational fluid dynamics in congenital heart disease
Computational fluid dynamics has been applied to the design, refinement, and assessment of surgical procedures and medical devices. This tool calculates flow patterns and pressure changes within a virtual model of the cardiovascular system. In the field of paediatric cardiac surgery, computational fluid dynamics is being used to elucidate the optimal approach to staged reconstruction of specific defects and study the haemodynamics of the resulting anatomical configurations after reconstructive or palliative surgery. In this paper, we review the techniques and principal findings of computational fluid dynamics studies as applied to a few representative forms of congenital heart disease.
- 1 December 2000
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 24 (10) , 707-713
Explicit boundary element method for nonlinear solid mechanics using domain integral reduction
- 1 December 2000
- Published by Elsevier in Engineering Analysis with Boundary Elements
- Vol. 24 (10) , 707-713
Explicit boundary element method for nonlinear solid mechanics using domain integral reduction
- 1 July 1997
- Published by Taylor & Francis in Numerical Heat Transfer, Part B: Fundamentals
- Vol. 32 (1) , 37-61
A GENERALIZED BOUNDARY-ELEMENT METHOD FOR STEADY-STATE HEAT CONDUCTION IN HETEROGENEOUS ANISOTROPIC MEDIA
A generalized boundary integral equation (BIE) is formulated for heat conduction problems in anisotropic media with spatially varying thermal conductivities arising from material heterogeneity. The generalized integral equation is expressed in terms of contour integrals only. This is accomplished with the aid of a generalized fundamental solution E and with the definition of a singular nonsymmetric generalized forcing function, D. Generalized fundamental solutions, E, are derived as locally radially symmetric responses to this nonsymmetric singular forcing function, D. Both E and D are defined in terms of the thermal conductivity of the medium. Although it is locally radially symmetric about the source point, E varies within the domain as the source point changes position. Examples of generalized fundamental solutions are provided for various thermal conductivities along with the corresponding forcing function, D. Numerical implementation is discussed. Numerical results are provided for several examples with spatially variable thermal conductivity in isotropic, orthotropic, and fully anisotropic heterogeneous media. Problems ore solved in 2-D and 3-D regular and irregular regions with single- and multiply-connected domains. Close agreement found between the generalized BIE solution and exact solutions validates the formulation developed in this article.
- 1 July 1997
- Published by Taylor & Francis in Numerical Heat Transfer, Part B: Fundamentals
- Vol. 32 (1) , 37-61
A GENERALIZED BOUNDARY-ELEMENT METHOD FOR STEADY-STATE HEAT CONDUCTION IN HETEROGENEOUS ANISOTROPIC MEDIA
A generalized boundary integral equation (BIE) is formulated for heat conduction problems in anisotropic media with spatially varying thermal conductivities arising from material heterogeneity. The generalized integral equation is expressed in terms of contour integrals only. This is accomplished with the aid of a generalized fundamental solution E and with the definition of a singular nonsymmetric generalized forcing function, D. Generalized fundamental solutions, E, are derived as locally radially symmetric responses to this nonsymmetric singular forcing function, D. Both E and D are defined in terms of the thermal conductivity of the medium. Although it is locally radially symmetric about the source point, E varies within the domain as the source point changes position. Examples of generalized fundamental solutions are provided for various thermal conductivities along with the corresponding forcing function, D. Numerical implementation is discussed. Numerical results are provided for several examples with spatially variable thermal conductivity in isotropic, orthotropic, and fully anisotropic heterogeneous media. Problems ore solved in 2-D and 3-D regular and irregular regions with single- and multiply-connected domains. Close agreement found between the generalized BIE solution and exact solutions validates the formulation developed in this article.