Elizabeth M. Sweeney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elizabeth M. Sweeney has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ajay Gupta
Department of Radiology, Weill Cornell Medicine
2 shared publications - Emily Demmon
Department of Neurology (E.D., W.M., M.S., S.A.G.), Weill Cornell Medicine, New York, New York
2 shared publications - Michael Sakirsky
Department of Neurology (E.D., W.M., M.S., S.A.G.), Weill Cornell Medicine, New York, New York
2 shared publications - Susan A. Gauthier
Department of Neurology, Weill Cornell Medicine, New York, USA
2 shared publications - Thanh Duc Nguyen
Department of Radiology Weill Cornell Medicine New York New York USA
2 shared publications - Yi Wang
Department of Radiology Weill Cornell Medicine New York New York USA
2 shared publications
Latest Publications
- Open Access
- 4 May 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (6) , 649-655
Evaluation of the Statistical Detection of Change Algorithm for Screening Patients with MS with New Lesion Activity on Longitudinal Brain MRI
BACKGROUND AND PURPOSE: Identification of new MS lesions on longitudinal MR imaging by human readers is time-consuming and prone to error. Our objective was to evaluate the improvement in the performance of subject-level detection by readers when assisted by the automated statistical detection of change algorithm. MATERIALS AND METHODS: A total of 200 patients with MS with a mean interscan interval of 13.2 (SD, 2.4) months were included. Statistical detection of change was applied to the baseline and follow-up FLAIR images to detect potential new lesions for confirmation by readers (Reader + statistical detection of change method). This method was compared with readers operating in the clinical workflow (Reader method) for a subject-level detection of new lesions. RESULTS: Reader + statistical detection of change found 30 subjects (15.0%) with at least 1 new lesion, while Reader detected 16 subjects (8.0%). As a subject-level screening tool, statistical detection of change achieved a perfect sensitivity of 1.00 (95% CI, 0.88–1.00) and a moderate specificity of 0.67 (95% CI, 0.59–0.74). The agreement on a subject level was 0.91 (95% CI, 0.87–0.95) between Reader + statistical detection of change and Reader, and 0.72 (95% CI, 0.66–0.78) between Reader + statistical detection of change and statistical detection of change. CONCLUSIONS: The statistical detection of change algorithm can serve as a time-saving screening tool to assist human readers in verifying 3D FLAIR images of patients with MS with suspected new lesions. Our promising results warrant further evaluation of statistical detection of change in prospective multireader clinical studies.
- 4 May 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (6) , 649-655
Open AccessEvaluation of the Statistical Detection of Change Algorithm for Screening Patients with MS with New Lesion Activity on Longitudinal Brain MRI
BACKGROUND AND PURPOSE: Identification of new MS lesions on longitudinal MR imaging by human readers is time-consuming and prone to error. Our objective was to evaluate the improvement in the performance of subject-level detection by readers when assisted by the automated statistical detection of change algorithm. MATERIALS AND METHODS: A total of 200 patients with MS with a mean interscan interval of 13.2 (SD, 2.4) months were included. Statistical detection of change was applied to the baseline and follow-up FLAIR images to detect potential new lesions for confirmation by readers (Reader + statistical detection of change method). This method was compared with readers operating in the clinical workflow (Reader method) for a subject-level detection of new lesions. RESULTS: Reader + statistical detection of change found 30 subjects (15.0%) with at least 1 new lesion, while Reader detected 16 subjects (8.0%). As a subject-level screening tool, statistical detection of change achieved a perfect sensitivity of 1.00 (95% CI, 0.88–1.00) and a moderate specificity of 0.67 (95% CI, 0.59–0.74). The agreement on a subject level was 0.91 (95% CI, 0.87–0.95) between Reader + statistical detection of change and Reader, and 0.72 (95% CI, 0.66–0.78) between Reader + statistical detection of change and statistical detection of change. CONCLUSIONS: The statistical detection of change algorithm can serve as a time-saving screening tool to assist human readers in verifying 3D FLAIR images of patients with MS with suspected new lesions. Our promising results warrant further evaluation of statistical detection of change in prospective multireader clinical studies.
- Open Access
Evaluation of statistical detection of change algorithm for triaging multiple sclerosis patients with new lesion activity on longitudinal brain MRI
Background and Purpose Identification of new MS lesions on longitudinal MRI by human readers is time-consuming and prone to error. Our objective was to evaluate the improvement in a subject-level detection performance by readers when assisted by the automated statistical detection of change (SDC) algorithm. Materials and Methods A total of 200 MS patients with mean inter-scan interval of 13.2 ± 2.4 months were included. SDC was applied to the baseline and follow-up FLAIR images to detect potential new lesions for confirmation by readers (Reader+SDC method). This method was compared with readers operating in the clinical workflow (Reader method) for a subject-level detection of new lesions. Results Reader+SDC found 30 subjects (15.0%) with at least one new lesion, while Reader detected 16 subjects (8.0%). As a subject-level triage tool, SDC achieved a perfect sensitivity of 1.00 (95% CI: [0.88, 1.00]) and a moderate specificity of 0.67 (95% CI: [0.59, 0.74]). The agreement on a subject-level was 0.91 (95% CI: [0.87, 0.95]) between Reader+SDC and Reader, and 0.72 (95% CI: [0.66, 0.78]) between Reader+SDC and SDC. Conclusion SDC improves the detection accuracy of human readers and can serve as a time-saving patient triage tool for detecting new MS lesion activity on longitudinal FLAIR images.
Open AccessEvaluation of statistical detection of change algorithm for triaging multiple sclerosis patients with new lesion activity on longitudinal brain MRI
Background and Purpose Identification of new MS lesions on longitudinal MRI by human readers is time-consuming and prone to error. Our objective was to evaluate the improvement in a subject-level detection performance by readers when assisted by the automated statistical detection of change (SDC) algorithm. Materials and Methods A total of 200 MS patients with mean inter-scan interval of 13.2 ± 2.4 months were included. SDC was applied to the baseline and follow-up FLAIR images to detect potential new lesions for confirmation by readers (Reader+SDC method). This method was compared with readers operating in the clinical workflow (Reader method) for a subject-level detection of new lesions. Results Reader+SDC found 30 subjects (15.0%) with at least one new lesion, while Reader detected 16 subjects (8.0%). As a subject-level triage tool, SDC achieved a perfect sensitivity of 1.00 (95% CI: [0.88, 1.00]) and a moderate specificity of 0.67 (95% CI: [0.59, 0.74]). The agreement on a subject-level was 0.91 (95% CI: [0.87, 0.95]) between Reader+SDC and Reader, and 0.72 (95% CI: [0.66, 0.78]) between Reader+SDC and SDC. Conclusion SDC improves the detection accuracy of human readers and can serve as a time-saving patient triage tool for detecting new MS lesion activity on longitudinal FLAIR images.