Le Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Le Yang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Wenbin Zhang
College of Mechanical and Electrical Engineering, Kunming University of Science and Technology, Kunming 650504, China
3 shared publications - Fangrong Zhou
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
2 shared publications - Gang Ao
Kunming Anning Power Supply Bureau, Yunnan Power Grid Co., Ltd., Kunming 650300, China
2 shared publications - Xiangyu Tan
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
2 shared publications - Xiaowei Xu
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650217, China
2 shared publications - Fangrong Zhou
Electric Power Research Institute, Yunnan Power Grid Co., Ltd., Kunming 650000, China
1 shared publication
Latest Publications
- Open Access
Surface Wear Monitoring System of Industrial Transformer Tap-Changer Contacts by Using Voice Signal
Surface wear of the tap-changer contacts of industrial transformers (due to frequent switching times) easily leads to operation failure of industrial transformers, which affects the safety and stability of the transmission network. In this paper, an intelligent voice signal monitoring system was proposed for the abnormal condition (surface wear) of tap-changer contacts. This monitoring system was composed of a voice signal acquisition system, voice analysis system and voice processing system. First, the voice signal of the tap-changer contacts was collected, and the collected voice signal was analyzed in the time domain and the frequency domain. Secondly, the characteristic curve of the voice signal was proposed, and the voice curve was compared with that of the normal operation state. In this case, the running state and surface wear abnormal situation of the tap changer could be monitored and determined, and the cause of the abnormal state could also be further analyzed. This method solved the surface wear problem of the tap changer in industrial transformers, which could be not monitored effectively in real time. This method improved the operational reliability of industrial transformers and had high economic and social benefits.
Open AccessSurface Wear Monitoring System of Industrial Transformer Tap-Changer Contacts by Using Voice Signal
Surface wear of the tap-changer contacts of industrial transformers (due to frequent switching times) easily leads to operation failure of industrial transformers, which affects the safety and stability of the transmission network. In this paper, an intelligent voice signal monitoring system was proposed for the abnormal condition (surface wear) of tap-changer contacts. This monitoring system was composed of a voice signal acquisition system, voice analysis system and voice processing system. First, the voice signal of the tap-changer contacts was collected, and the collected voice signal was analyzed in the time domain and the frequency domain. Secondly, the characteristic curve of the voice signal was proposed, and the voice curve was compared with that of the normal operation state. In this case, the running state and surface wear abnormal situation of the tap changer could be monitored and determined, and the cause of the abnormal state could also be further analyzed. This method solved the surface wear problem of the tap changer in industrial transformers, which could be not monitored effectively in real time. This method improved the operational reliability of industrial transformers and had high economic and social benefits.
- Open Access
Research Progress on the Application of Graphene Quantum Dots
Graphene quantum dots (GQDs) are sets of carbon quantum dots derived from graphene or graphene oxide, and they have obvious graphene lattice properties. The number of layers in GQDs is generally no more than five layers, and the diameter size of GQDs is generally less than 10 nm. GQDs have stable photoluminescence characteristics, high specific surface areas, high conductivity levels and adjustable band gaps, and they can be used in sensing systems such as ion detection sensing, optical biosensing, electrochemical biosensing and electronic sensing. Based on the research status of GQDs in recent years and the application background of sensing systems, this review paper focuses on the synthesis strategies, sizes, chemical compositions, crystal structures, optical properties and sensor applications of GQDs.
Open AccessResearch Progress on the Application of Graphene Quantum Dots
Graphene quantum dots (GQDs) are sets of carbon quantum dots derived from graphene or graphene oxide, and they have obvious graphene lattice properties. The number of layers in GQDs is generally no more than five layers, and the diameter size of GQDs is generally less than 10 nm. GQDs have stable photoluminescence characteristics, high specific surface areas, high conductivity levels and adjustable band gaps, and they can be used in sensing systems such as ion detection sensing, optical biosensing, electrochemical biosensing and electronic sensing. Based on the research status of GQDs in recent years and the application background of sensing systems, this review paper focuses on the synthesis strategies, sizes, chemical compositions, crystal structures, optical properties and sensor applications of GQDs.
- Open Access
Online Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices.
Open AccessOnline Calibration Study of Non-Contact Current Sensors for Three-Phase Four-Wire Power Cables
Three-phase four-wire power cables are a primary kind of power transmission method in low-voltage distribution networks. This paper addresses the problem that calibration currents are not easily electrified during the transporting of three-phase four-wire power cable measurements, and proposes a method for obtaining the magnetic field strength distribution in the tangential direction around the cable, finally enabling online self-calibration. The simulation and experimental results show that this method can self-calibrate the sensor arrays and reconstruct the phase current waveforms in three-phase four-wire power cables without calibration currents, and this method is not affected by disturbances such as wire diameter, current amplitudes, and high-frequency harmonics. This study reduces the time and equipment costs required to calibrate the sensing module compared to related studies using calibration currents. This research offers the possibility of fusing sensing modules directly with running primary equipment, and the development of hand-held measurement devices.
- Open Access
- 6 February 2023
- Published by MDPI AG in Electronics
- Vol. 12 (4) , 814
Transmission Line Voltage Calibration-Free Measurement Method
Voltage sensing technology is crucial in realizing distributed voltage sensing at critical nodes of the power grid and providing key state variables to provide information support for control decisions. Among the existing voltage measurement methods, voltage transformers have problems such as high insulation performance requirements and limited installation locations. However, non-contact voltage sensors designed based on the electric field coupling principle have sensor accuracy problems due to the instability of the coupling capacitance. Based on the above problems, this paper first proposes a floating ground measurement system based on an equipotential and differential structure. It also proposes a dual capacitance equivalent model for AC voltage measurement on transmission lines. Based on this method, a calibration method for the amplitude and phase of the sensor is built. Under the voltage test at 50 Hz operating frequency in the voltage range (100–300 V), the maximum relative error of the voltage amplitude is 0.89%, and the maximum relative error of the voltage phase is 0.68°. The maximum relative error of voltage amplitude under a 50 Hz operating frequency voltage test in the voltage range (600 V–10 kV) is 4.48%. In the final scenario adaptation analysis, the method’s specific height amplitude accuracy error was experimentally verified to be 0.88%, with a maximum difference of 0.52% for multi-type conductor testing.
- 6 February 2023
- Published by MDPI AG in Electronics
- Vol. 12 (4) , 814
Open AccessTransmission Line Voltage Calibration-Free Measurement Method
Voltage sensing technology is crucial in realizing distributed voltage sensing at critical nodes of the power grid and providing key state variables to provide information support for control decisions. Among the existing voltage measurement methods, voltage transformers have problems such as high insulation performance requirements and limited installation locations. However, non-contact voltage sensors designed based on the electric field coupling principle have sensor accuracy problems due to the instability of the coupling capacitance. Based on the above problems, this paper first proposes a floating ground measurement system based on an equipotential and differential structure. It also proposes a dual capacitance equivalent model for AC voltage measurement on transmission lines. Based on this method, a calibration method for the amplitude and phase of the sensor is built. Under the voltage test at 50 Hz operating frequency in the voltage range (100–300 V), the maximum relative error of the voltage amplitude is 0.89%, and the maximum relative error of the voltage phase is 0.68°. The maximum relative error of voltage amplitude under a 50 Hz operating frequency voltage test in the voltage range (600 V–10 kV) is 4.48%. In the final scenario adaptation analysis, the method’s specific height amplitude accuracy error was experimentally verified to be 0.88%, with a maximum difference of 0.52% for multi-type conductor testing.
- Open Access
- 27 January 2022
- Published by MDPI AG in Electronics
- Vol. 11 (3) , 381
Design of Open-Ended Structure Wideband PCB Rogowski Coil Based on New Winding Method
Compared with the traditional Rogowski coil, printed circuit board (PCB) Rogowski coil has the advantages of high measurement accuracy, simple manufacturing process and low cost. It has become an important device in current measurement. However, the existing PCB Rogowski coils are mostly closed, and the open-ended structure PCB Rogowski coils are susceptible to external magnetic field interference. This paper proposes an open-ended structure PCB Rogowski coil based on a new winding method, so that the two open-ended PCB Rogowski coils are evenly distributed when closed, while improving the coil’s immunity to external magnetic fields based on the winding method of equal area of the de-wired and loop. In addition, this paper uses the hybrid integration circuit and the back-end matching method to achieve the broadband measurement performance of the sensor. Finally, the experimental results show that the mutual inductance difference between the closed and open-ended structure PCB Rogowski coil is less than 0.5% under the same wiring mode. Under the equivalent current interference at 50 mm from the measured current, the maximum interference coefficient of the open-ended structure coil is 1.45%; in sine sweep and pulse current test conditions, the frequency band is 34 Hz–3.5 MHz.
- 27 January 2022
- Published by MDPI AG in Electronics
- Vol. 11 (3) , 381
Open AccessDesign of Open-Ended Structure Wideband PCB Rogowski Coil Based on New Winding Method
Compared with the traditional Rogowski coil, printed circuit board (PCB) Rogowski coil has the advantages of high measurement accuracy, simple manufacturing process and low cost. It has become an important device in current measurement. However, the existing PCB Rogowski coils are mostly closed, and the open-ended structure PCB Rogowski coils are susceptible to external magnetic field interference. This paper proposes an open-ended structure PCB Rogowski coil based on a new winding method, so that the two open-ended PCB Rogowski coils are evenly distributed when closed, while improving the coil’s immunity to external magnetic fields based on the winding method of equal area of the de-wired and loop. In addition, this paper uses the hybrid integration circuit and the back-end matching method to achieve the broadband measurement performance of the sensor. Finally, the experimental results show that the mutual inductance difference between the closed and open-ended structure PCB Rogowski coil is less than 0.5% under the same wiring mode. Under the equivalent current interference at 50 mm from the measured current, the maximum interference coefficient of the open-ended structure coil is 1.45%; in sine sweep and pulse current test conditions, the frequency band is 34 Hz–3.5 MHz.