Priyan D. Weerappuli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Priyan D. Weerappuli has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Shuichi Takayama
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
2 shared publications - Chao Zhang
Department of Biomedical Engineering, Biointerfaces Institute, University of Michigan, Ann Arbor, MI 48109, USA
1 shared publication - Jason S. Knight
Division of Rheumatology, Department of Internal Medicine, University of Michigan, Ann Arbor, MI, USA
1 shared publication - Katherine Nguyen
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
1 shared publication - Midori L. Wasielewski
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
1 shared publication - Pallavi Ekbote
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
1 shared publication
Latest Publications
- Open Access
- 6 February 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (4) , 3222
Visualization of Nuclease- and Serum-Mediated Chromatin Degradation with DNA–Histone Mesostructures
This study analyzed the nuclease- and serum-driven degradation of millimeter-scale, circular DNA–histone mesostructures (DHMs). DHMs are bioengineered chromatin meshes of defined DNA and histone compositions designed as minimal mimetics of physiological extracellular chromatin structures, such as neutrophil extracellular traps (NETs). Taking advantage of the defined circular shape of the DHMs, an automated time-lapse imaging and image analysis method was developed and used to track DHM degradation and shape changes over time. DHMs were degraded well by 10 U/mL concentrations of deoxyribonuclease I (DNase I) but not by the same level of micrococcal nuclease (MNase), whereas NETs were degraded well by both nucleases. These comparative observations suggest that DHMs have a less accessible chromatin structure compared to NETs. DHMs were degraded by normal human serum, although at a slower rate than NETs. Interestingly, time-lapse images of DHMs revealed qualitative differences in the serum-mediated degradation process compared to that mediated by DNase I. Importantly, despite their reduced susceptibility to degradation and compositional simplicity, the DHMs mimicked NETs in being degraded to a greater extent by normal donor serum compared to serum from a lupus patient with high disease activity. These methods and insights are envisioned to guide the future development and expanded use of DHMs, beyond the previously reported antibacterial and immunostimulatory analyses, to extracellular chromatin-related pathophysiological and diagnostic studies.
- 6 February 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (4) , 3222
Open AccessVisualization of Nuclease- and Serum-Mediated Chromatin Degradation with DNA–Histone Mesostructures
This study analyzed the nuclease- and serum-driven degradation of millimeter-scale, circular DNA–histone mesostructures (DHMs). DHMs are bioengineered chromatin meshes of defined DNA and histone compositions designed as minimal mimetics of physiological extracellular chromatin structures, such as neutrophil extracellular traps (NETs). Taking advantage of the defined circular shape of the DHMs, an automated time-lapse imaging and image analysis method was developed and used to track DHM degradation and shape changes over time. DHMs were degraded well by 10 U/mL concentrations of deoxyribonuclease I (DNase I) but not by the same level of micrococcal nuclease (MNase), whereas NETs were degraded well by both nucleases. These comparative observations suggest that DHMs have a less accessible chromatin structure compared to NETs. DHMs were degraded by normal human serum, although at a slower rate than NETs. Interestingly, time-lapse images of DHMs revealed qualitative differences in the serum-mediated degradation process compared to that mediated by DNase I. Importantly, despite their reduced susceptibility to degradation and compositional simplicity, the DHMs mimicked NETs in being degraded to a greater extent by normal donor serum compared to serum from a lupus patient with high disease activity. These methods and insights are envisioned to guide the future development and expanded use of DHMs, beyond the previously reported antibacterial and immunostimulatory analyses, to extracellular chromatin-related pathophysiological and diagnostic studies.
- Open Access
- 27 November 2014
- Published by MDPI AG in Micromachines
- Vol. 5 (4) , 1254-1269
Predictable Duty Cycle Modulation through Coupled Pairing of Syringes with Microfluidic Oscillators
The ability to elicit distinct duty cycles from the same self-regulating microfluidic oscillator device would greatly enhance the versatility of this micro-machine as a tool, capable of recapitulating in vitro the diverse oscillatory processes that occur within natural systems. We report a novel approach to realize this using the coordinated modulation of input volumetric flow rate ratio and fluidic capacitance ratio. The demonstration uses a straightforward experimental system where fluid inflow to the oscillator is provided by two syringes (of symmetric or asymmetric cross-sectional area) mounted upon a single syringe pump applying pressure across both syringes at a constant linear velocity. This produces distinct volumetric outflow rates from each syringe that are proportional to the ratio between their cross-sectional areas. The difference in syringe cross-sectional area also leads to differences in fluidic capacitance; this underappreciated capacitive difference allows us to present a simplified expression to determine the microfluidic oscillators duty cycle as a function of cross-sectional area. Examination of multiple total volumetric inflows under asymmetric inflow rates yielded predictable and robust duty cycles ranging from 50% to 90%. A method for estimating the outflow duration for each inflow under applied flow rate ratios is provided to better facilitate the utilization of this system in experimental protocols requiring specific stimulation and rest intervals.
- 27 November 2014
- Published by MDPI AG in Micromachines
- Vol. 5 (4) , 1254-1269
Open AccessPredictable Duty Cycle Modulation through Coupled Pairing of Syringes with Microfluidic Oscillators
The ability to elicit distinct duty cycles from the same self-regulating microfluidic oscillator device would greatly enhance the versatility of this micro-machine as a tool, capable of recapitulating in vitro the diverse oscillatory processes that occur within natural systems. We report a novel approach to realize this using the coordinated modulation of input volumetric flow rate ratio and fluidic capacitance ratio. The demonstration uses a straightforward experimental system where fluid inflow to the oscillator is provided by two syringes (of symmetric or asymmetric cross-sectional area) mounted upon a single syringe pump applying pressure across both syringes at a constant linear velocity. This produces distinct volumetric outflow rates from each syringe that are proportional to the ratio between their cross-sectional areas. The difference in syringe cross-sectional area also leads to differences in fluidic capacitance; this underappreciated capacitive difference allows us to present a simplified expression to determine the microfluidic oscillators duty cycle as a function of cross-sectional area. Examination of multiple total volumetric inflows under asymmetric inflow rates yielded predictable and robust duty cycles ranging from 50% to 90%. A method for estimating the outflow duration for each inflow under applied flow rate ratios is provided to better facilitate the utilization of this system in experimental protocols requiring specific stimulation and rest intervals.