Nicola Fink
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicola Fink has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Tilman Emrich
Department of Radiology and Radiological Science Medical University of South Carolina Charleston South Carolina USA
4 shared publications - Akos Varga-Szemes
Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA
3 shared publications - Joseph P. Griffith
Department of Radiology and Radiological Sciences, The Medical University of South Carolina, Charleston, SC, USA
3 shared publications - Uwe Joseph Schoepf
Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
3 shared publications - Christian Tesche
Klinik für Kardiologie und Intensivmedizin, Augustinum Klinik München, Lehrkrankenhaus der Ludwig-Maximilians-Universität München, Wolkerweg 16, 81375, München, Deutschland.
2 shared publications - Emese Zsarnoczay
Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Dr, Charleston, SC 29425, USA
2 shared publications
Latest Publications
- Open Access
- 1 June 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1937
Optimization of Kernel Type and Sharpness Level Improves Objective and Subjective Image Quality for High-Pitch Photon Counting Coronary CT Angiography
(1) Background: Photon-counting detector (PCD) CT offers a wide variety of kernels and sharpness levels for image reconstruction. The aim of this retrospective study was to determine optimal settings for coronary CT angiography (CCTA). (2) Methods: Thirty patients (eight female, mean age 63 ± 13 years) underwent PCD-CCTA in a high-pitch mode. Images were reconstructed using three different kernels and four sharpness levels (Br36/40/44/48, Bv36/40/44/48, and Qr36/40/44/48). To analyze objective image quality, the attenuation, image noise, contrast-to-noise ratio (CNR), and vessel sharpness were quantified in proximal and distal coronaries. For subjective image quality, two blinded readers assessed image noise, visually sharp reproduction of coronaries, and the overall image quality using a five-point Likert scale. (3) Results: Attenuation, image noise, CNR, and vessel sharpness significantly differed across kernels (all p < 0.001), with the Br-kernel reaching the highest attenuation. With increasing kernel sharpness, image noise and vessel sharpness increased, whereas CNR continuously decreased. Reconstruction with Br-kernel generally had the highest CNR (Br > Bv > Qr), except Bv-kernel had a superior CNR at sharpness level 40. Bv-kernel had significantly higher vessel sharpness than Br- and Qr-kernel (p < 0.001). Subjective image quality was rated best for kernels Bv40 and Bv36, followed by Br36 and Qr36. (4) Conclusion: Reconstructions with kernel Bv40 are beneficial to achieve optimal image quality in spectral high-pitch CCTA using PCD-CT.
- 1 June 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (11) , 1937
Open AccessOptimization of Kernel Type and Sharpness Level Improves Objective and Subjective Image Quality for High-Pitch Photon Counting Coronary CT Angiography
(1) Background: Photon-counting detector (PCD) CT offers a wide variety of kernels and sharpness levels for image reconstruction. The aim of this retrospective study was to determine optimal settings for coronary CT angiography (CCTA). (2) Methods: Thirty patients (eight female, mean age 63 ± 13 years) underwent PCD-CCTA in a high-pitch mode. Images were reconstructed using three different kernels and four sharpness levels (Br36/40/44/48, Bv36/40/44/48, and Qr36/40/44/48). To analyze objective image quality, the attenuation, image noise, contrast-to-noise ratio (CNR), and vessel sharpness were quantified in proximal and distal coronaries. For subjective image quality, two blinded readers assessed image noise, visually sharp reproduction of coronaries, and the overall image quality using a five-point Likert scale. (3) Results: Attenuation, image noise, CNR, and vessel sharpness significantly differed across kernels (all p < 0.001), with the Br-kernel reaching the highest attenuation. With increasing kernel sharpness, image noise and vessel sharpness increased, whereas CNR continuously decreased. Reconstruction with Br-kernel generally had the highest CNR (Br > Bv > Qr), except Bv-kernel had a superior CNR at sharpness level 40. Bv-kernel had significantly higher vessel sharpness than Br- and Qr-kernel (p < 0.001). Subjective image quality was rated best for kernels Bv40 and Bv36, followed by Br36 and Qr36. (4) Conclusion: Reconstructions with kernel Bv40 are beneficial to achieve optimal image quality in spectral high-pitch CCTA using PCD-CT.
- Open Access
- 25 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (9) , 1540
Radiation Dose Reduction for Coronary Artery Calcium Scoring Using a Virtual Noniodine Algorithm on Photon-Counting Detector Computed-Tomography Phantom Data
Background: On the basis of the hypothesis that virtual noniodine (VNI)-based coronary artery calcium scoring (CACS) is feasible at reduced radiation doses, this study assesses the impact of radiation dose reduction on the accuracy of this VNI algorithm on a photon-counting detector (PCD)-CT. Methods: In a systematic in vitro setting, a phantom for CACS simulating three chest sizes was scanned on a clinical PCD-CT. The standard radiation dose was chosen at volumetric CT dose indices (CTDIVol) of 1.5, 3.3, 7.0 mGy for small, medium-sized, and large phantoms, and was gradually reduced by adjusting the tube current resulting in 100, 75, 50, and 25%, respectively. VNI images were reconstructed at 55 keV, quantum iterative reconstruction (QIR)1, and at 60 keV/QIR4, and evaluated regarding image quality (image noise (IN), contrast-to-noise ratio (CNR)), and CACS. All VNI results were compared to true noncontrast (TNC)-based CACS at 70 keV and standard radiation dose (reference). Results: INTNC was significantly higher than INVNI, and INVNI at 55 keV/QIR1 higher than at 60 keV/QIR4 (100% dose: 16.7 ± 1.9 vs. 12.8 ± 1.7 vs. 7.7 ± 0.9; p < 0.001 for every radiation dose). CNRTNC was higher than CNRVNI, but it was better to use 60 keV/QIR4 (p < 0.001). CACSVNI showed strong correlation and agreement at every radiation dose (p < 0.001, r > 0.9, intraclass correlation coefficient > 0.9). The coefficients of the variation in root-mean squared error were less than 10% and thus clinically nonrelevant for the CACSVNI of every radiation dose. Conclusion: This phantom study suggests that CACSVNI is feasible on PCD-CT, even at reduced radiation dose while maintaining image quality and CACS accuracy.
- 25 April 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (9) , 1540
Open AccessRadiation Dose Reduction for Coronary Artery Calcium Scoring Using a Virtual Noniodine Algorithm on Photon-Counting Detector Computed-Tomography Phantom Data
Background: On the basis of the hypothesis that virtual noniodine (VNI)-based coronary artery calcium scoring (CACS) is feasible at reduced radiation doses, this study assesses the impact of radiation dose reduction on the accuracy of this VNI algorithm on a photon-counting detector (PCD)-CT. Methods: In a systematic in vitro setting, a phantom for CACS simulating three chest sizes was scanned on a clinical PCD-CT. The standard radiation dose was chosen at volumetric CT dose indices (CTDIVol) of 1.5, 3.3, 7.0 mGy for small, medium-sized, and large phantoms, and was gradually reduced by adjusting the tube current resulting in 100, 75, 50, and 25%, respectively. VNI images were reconstructed at 55 keV, quantum iterative reconstruction (QIR)1, and at 60 keV/QIR4, and evaluated regarding image quality (image noise (IN), contrast-to-noise ratio (CNR)), and CACS. All VNI results were compared to true noncontrast (TNC)-based CACS at 70 keV and standard radiation dose (reference). Results: INTNC was significantly higher than INVNI, and INVNI at 55 keV/QIR1 higher than at 60 keV/QIR4 (100% dose: 16.7 ± 1.9 vs. 12.8 ± 1.7 vs. 7.7 ± 0.9; p < 0.001 for every radiation dose). CNRTNC was higher than CNRVNI, but it was better to use 60 keV/QIR4 (p < 0.001). CACSVNI showed strong correlation and agreement at every radiation dose (p < 0.001, r > 0.9, intraclass correlation coefficient > 0.9). The coefficients of the variation in root-mean squared error were less than 10% and thus clinically nonrelevant for the CACSVNI of every radiation dose. Conclusion: This phantom study suggests that CACSVNI is feasible on PCD-CT, even at reduced radiation dose while maintaining image quality and CACS accuracy.
- 16 February 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 161, 110746
Ultra-high resolution photon-counting coronary CT angiography improves coronary stenosis quantification over a wide range of heart rates – A dynamic phantom study
- 16 February 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 161, 110746
Ultra-high resolution photon-counting coronary CT angiography improves coronary stenosis quantification over a wide range of heart rates – A dynamic phantom study
- Open Access
- 8 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 624
Gender Differences in Epicardial Adipose Tissue and Plaque Composition by Coronary CT Angiography: Association with Cardiovascular Outcome
Background: To investigate gender differences in epicardial adipose tissue (EAT) and plaque composition by coronary CT angiography (CCTA) and the association with cardiovascular outcome. Methods: Data of 352 patients (64.2 ± 10.3 years, 38% female) with suspected coronary artery disease (CAD) who underwent CCTA were retrospectively analyzed. EAT volume and plaque composition from CCTA were compared between men and women. Major adverse cardiovascular events (MACE) were recorded from follow-up. Results: Men were more likely to have obstructive CAD, higher Agatston scores, and a larger total and non-calcified plaque burden. In addition, men displayed more adverse plaque characteristics and EAT volume compared to women (all p < 0.05). After a median follow-up of 5.1 years, MACE occurred in 8 women (6%) and 22 men (10%). In multivariable analysis, Agatston calcium score (HR 1.0008, p = 0.014), EAT volume (HR 1.067, p = 0.049), and low-attenuation plaque (HR 3.82, p = 0.036) were independent predictors for MACE in men, whereas only low-attenuation plaque (HR 2.42, p = 0.041) showed predictive value for events in women. Conclusion: Women demonstrated less overall plaque burden, fewer adverse plaque characteristics, and a smaller EAT volume compared to men. However, low-attenuation plaque is a predictor for MACE in both genders. Thus, a differentiated plaque analysis is warranted to understand gender differences of atherosclerosis to guide medical therapy and prevention strategies.
- 8 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 624
Open AccessGender Differences in Epicardial Adipose Tissue and Plaque Composition by Coronary CT Angiography: Association with Cardiovascular Outcome
Background: To investigate gender differences in epicardial adipose tissue (EAT) and plaque composition by coronary CT angiography (CCTA) and the association with cardiovascular outcome. Methods: Data of 352 patients (64.2 ± 10.3 years, 38% female) with suspected coronary artery disease (CAD) who underwent CCTA were retrospectively analyzed. EAT volume and plaque composition from CCTA were compared between men and women. Major adverse cardiovascular events (MACE) were recorded from follow-up. Results: Men were more likely to have obstructive CAD, higher Agatston scores, and a larger total and non-calcified plaque burden. In addition, men displayed more adverse plaque characteristics and EAT volume compared to women (all p < 0.05). After a median follow-up of 5.1 years, MACE occurred in 8 women (6%) and 22 men (10%). In multivariable analysis, Agatston calcium score (HR 1.0008, p = 0.014), EAT volume (HR 1.067, p = 0.049), and low-attenuation plaque (HR 3.82, p = 0.036) were independent predictors for MACE in men, whereas only low-attenuation plaque (HR 2.42, p = 0.041) showed predictive value for events in women. Conclusion: Women demonstrated less overall plaque burden, fewer adverse plaque characteristics, and a smaller EAT volume compared to men. However, low-attenuation plaque is a predictor for MACE in both genders. Thus, a differentiated plaque analysis is warranted to understand gender differences of atherosclerosis to guide medical therapy and prevention strategies.