Priya Narang
Research Subjects
Research Interests
Priya Narang has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Amar Agarwal
Dr. Agarwal's Group of Eye Hospitals, Chennai, India
15 shared publications Athiya Agarwal
7 shared publications- Alexandra Z. Crawford
School of Physics, Georgia Institute of Technology , 837 State Street, Atlanta, Georgia 30332, USA
6 shared publications Ashvin Agarwal
Dr. Agarwal’s Eye Hospital and Research Centre, Chennai, Tamil Nadu
6 shared publications- Ashvin Agarwal
Dr. Agarwal’s Eye Hospital & Research Centre, Chennai, India
6 shared publications Bennie H. Jeng
6 shared publications
Latest Publications
- 2 October 2024
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 34 (3) , 198-204
Comparison of Elisar-Fast and Sita-Fast Strategies for Visual Field Assessment in Glaucoma
Précis: The study documents the ability of Elisar-Fast to successfully assess visual field in patients with glaucoma. Purpose: To compare 2 fast threshold strategies of visual field assessment: SITA-Fast (SF; Humphrey field analyser) and Elisar-Fast (EF; advanced vision analyser) in patients with glaucoma. Methods: In this cross-sectional observational study, of total 192 subjects, 138 subjects (150 eyes, 80 glaucoma subjects [91 eyes] and 58 healthy controls [59 eyes]) were analysed and included. Each subject underwent 24-2 EF and SF in randomized order with a minimum time interval of 1 hour between tests. Main Outcome Measures: Mean test-time, pointwise and sectoral sensitivity, significance of values of mean sensitivity (MS) and global indices (mean deviation [MD] and pattern SD [PSD]) and their correlation. Results: The mean test-time was 2.59±0.25 and 3.38±0.28 minutes (P = 0.001) with SF and EF, respectively. Correlation coefficient for pointwise threshold values correlated strongly for both devices (range, 0.70–0.92). The intraclass correlation value of ≥0.8 was observed across all sectors, indicating good reliability. Bland-Altman plot denoted 95% of the data for MS values within limit of agreement. The intraclass correlation values for overall MS, MD, and PSD were 0.916, 0.913, and 0.872, respectively, indicating good reliability. High degree of correlation was observed for MD (r=0.912, P=0.00) and PSD values (r=0.732, P=0.00). Comparison of values indicated a difference of 1.09 dB for MD and 0.06 dB for PSD between both strategies. Conclusions: A high degree of correlation existed between the global indices and pointwise threshold values. The study documents the ability of EF to successfully assess visual field in patients with glaucoma.
- 2 October 2024
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 34 (3) , 198-204
Comparison of Elisar-Fast and Sita-Fast Strategies for Visual Field Assessment in Glaucoma
Précis: The study documents the ability of Elisar-Fast to successfully assess visual field in patients with glaucoma. Purpose: To compare 2 fast threshold strategies of visual field assessment: SITA-Fast (SF; Humphrey field analyser) and Elisar-Fast (EF; advanced vision analyser) in patients with glaucoma. Methods: In this cross-sectional observational study, of total 192 subjects, 138 subjects (150 eyes, 80 glaucoma subjects [91 eyes] and 58 healthy controls [59 eyes]) were analysed and included. Each subject underwent 24-2 EF and SF in randomized order with a minimum time interval of 1 hour between tests. Main Outcome Measures: Mean test-time, pointwise and sectoral sensitivity, significance of values of mean sensitivity (MS) and global indices (mean deviation [MD] and pattern SD [PSD]) and their correlation. Results: The mean test-time was 2.59±0.25 and 3.38±0.28 minutes (P = 0.001) with SF and EF, respectively. Correlation coefficient for pointwise threshold values correlated strongly for both devices (range, 0.70–0.92). The intraclass correlation value of ≥0.8 was observed across all sectors, indicating good reliability. Bland-Altman plot denoted 95% of the data for MS values within limit of agreement. The intraclass correlation values for overall MS, MD, and PSD were 0.916, 0.913, and 0.872, respectively, indicating good reliability. High degree of correlation was observed for MD (r=0.912, P=0.00) and PSD values (r=0.732, P=0.00). Comparison of values indicated a difference of 1.09 dB for MD and 0.06 dB for PSD between both strategies. Conclusions: A high degree of correlation existed between the global indices and pointwise threshold values. The study documents the ability of EF to successfully assess visual field in patients with glaucoma.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 264-269
Optimum pinhole size determination in pinhole pupilloplasty for higher-order aberrations
Purpose: To determine optimal pinhole size (OPS) and establish a relationship with visual acuity (VA) and RMS (root mean square) values in cases with higher-order aberrations (HOAs) undergoing pinhole pupilloplasty (PPP). Setting: Private practice, India. Design: Prospective, interventional study. Methods: RMS value for 6-mm–diameter optical zone was determined by Scheimpflug imaging (Pentacam). Patients with RMS value >0.3 μm were included. Preoperatively, a hand-held pinhole gauge with varied apertures determined the OPS, and single-pass four-throw technique was used to perform pupilloplasty with Purkinje-1 reflex as a marker for centration. VA with OPS, correlation of RMS values with OPS and pupil size, and Strehl ratio were the main outcome measures. Results: 29 eyes with HOAs were analyzed; all patients chose 1.0 or 1.5 mm as OPS. The mean preoperative and postoperative pupil size was 3.25 ± 0.81 mm and 1.8 ± 0.54 mm (P = .000), respectively. Postoperative mean pupil size when compared with OPS denoted that 14 eyes had a difference of r = 0.728; P = .00). Postoperative UDVA correlated well with VA measured with OPS (r = 0.847; P = .00). The preoperative and postoperative mean Strehl ratio was 0.109 ± 0.07 and 0.195 ± 0.11 (P = .001), respectively. Conclusions: Higher RMS values required a smaller pupil to achieve optimum VA. PPP can help achieve pinhole size in accordance with patient's optimum pinhole requirement.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 264-269
Optimum pinhole size determination in pinhole pupilloplasty for higher-order aberrations
Purpose: To determine optimal pinhole size (OPS) and establish a relationship with visual acuity (VA) and RMS (root mean square) values in cases with higher-order aberrations (HOAs) undergoing pinhole pupilloplasty (PPP). Setting: Private practice, India. Design: Prospective, interventional study. Methods: RMS value for 6-mm–diameter optical zone was determined by Scheimpflug imaging (Pentacam). Patients with RMS value >0.3 μm were included. Preoperatively, a hand-held pinhole gauge with varied apertures determined the OPS, and single-pass four-throw technique was used to perform pupilloplasty with Purkinje-1 reflex as a marker for centration. VA with OPS, correlation of RMS values with OPS and pupil size, and Strehl ratio were the main outcome measures. Results: 29 eyes with HOAs were analyzed; all patients chose 1.0 or 1.5 mm as OPS. The mean preoperative and postoperative pupil size was 3.25 ± 0.81 mm and 1.8 ± 0.54 mm (P = .000), respectively. Postoperative mean pupil size when compared with OPS denoted that 14 eyes had a difference of r = 0.728; P = .00). Postoperative UDVA correlated well with VA measured with OPS (r = 0.847; P = .00). The preoperative and postoperative mean Strehl ratio was 0.109 ± 0.07 and 0.195 ± 0.11 (P = .001), respectively. Conclusions: Higher RMS values required a smaller pupil to achieve optimum VA. PPP can help achieve pinhole size in accordance with patient's optimum pinhole requirement.
- 20 March 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (5) , 2042-2046
Reverse four-throw technique for pupilloplasty
Purpose: To describe Reverse four-throw (RFT) technique for pupilloplasty. Methods: The technique involves making a single pass through the anterior chamber that helps achieve a posteriorly directed suture knot. A single arm 9-0 polypropylene suture attached to long arm needle engages the iris defects with the tip of the needle piercing the iris tissue from the posterior surface and emerging from the anterior aspect. The suture end is passed from the loop with four throws taken consecutively in the same direction that create a self-sealing and self-retaining lock like single-pass four-throw technique but with the difference that the knot slides on the posterior surface of the iris tissue. Results: The technique was performed in 9 eyes and the suture-loop easily slided along the posterior surface of iris tissue. The iris defect was well approximated in all the cases and the suture knot or suture tail was not visible in the anterior chamber. Anterior segment optical coherence tomography depicted smooth iris configuration with no suture extrusion in the anterior chamber. Conclusions: The RFT technique provides an effective measure to seal the iris defect with the absence of knot in AC.
- 20 March 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (5) , 2042-2046
Reverse four-throw technique for pupilloplasty
Purpose: To describe Reverse four-throw (RFT) technique for pupilloplasty. Methods: The technique involves making a single pass through the anterior chamber that helps achieve a posteriorly directed suture knot. A single arm 9-0 polypropylene suture attached to long arm needle engages the iris defects with the tip of the needle piercing the iris tissue from the posterior surface and emerging from the anterior aspect. The suture end is passed from the loop with four throws taken consecutively in the same direction that create a self-sealing and self-retaining lock like single-pass four-throw technique but with the difference that the knot slides on the posterior surface of the iris tissue. Results: The technique was performed in 9 eyes and the suture-loop easily slided along the posterior surface of iris tissue. The iris defect was well approximated in all the cases and the suture knot or suture tail was not visible in the anterior chamber. Anterior segment optical coherence tomography depicted smooth iris configuration with no suture extrusion in the anterior chamber. Conclusions: The RFT technique provides an effective measure to seal the iris defect with the absence of knot in AC.
- 31 January 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (3) , NP145-NP147
Pinhole pupilloplasty (PPP) for refractive surprise after cataract surgery in post-laser in situ keratomileusis cases
- 31 January 2023
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 33 (3) , NP145-NP147
Pinhole pupilloplasty (PPP) for refractive surprise after cataract surgery in post-laser in situ keratomileusis cases
- Open Access
- 26 December 2022
- Published by Elsevier in Ophthalmology Science
- Vol. 3 (2) , 100264
Comparative Analysis of 10-2 Test on Advanced Vision Analyzer and Humphrey Perimeter in Glaucoma
- 26 December 2022
- Published by Elsevier in Ophthalmology Science
- Vol. 3 (2) , 100264
Open AccessComparative Analysis of 10-2 Test on Advanced Vision Analyzer and Humphrey Perimeter in Glaucoma
- Open Access
- 29 July 2022
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 70 (8) , 3166
Innovation Urrets-Zavalia syndrome
Background: Surgeons often notice unexplained dilation of the pupil following an uncomplicated intra-ocular surgery. No definite line of treatment has been proposed for managing Urrets-Zavalia syndrome (UZS). The authors have previously documented the results of surgical pupilloplasty and have outlined this modality of treatment for cases with UZS. Purpose: To highlight the aspect of development of UZS post-operatively in the eyes following an intra-ocular surgery. Synopsis: The video highlights the aspect of prevalence of the persistently dilated pupil that is non-responsive to topical miotics. Apart from associated glare, these cases often have raised intra-ocular pressure because of appositional closure of the anterior chamber angle. Surgical pupilloplasty pulls the iris tissue centrally, eventually releasing the mechanical blockage and often breakage of the peripheral anterior synechias as demonstrated by intra-operative gonioscopy and anterior segment optical coherence tomography. Highlights: Performing a surgical pupilloplasty can resolve the UZS, and timely intervention can also prevent the development of secondary glaucoma because of fallback of the iris tissue on the structures of the anterior chamber angle. Online Video Link: https://youtu.be/IF_w8dVk5_w Key words: Dilated pupil, SFT, single-pass four-throw, surgical pupilloplasty, Urrets-Zavalia, UZS
- 29 July 2022
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 70 (8) , 3166
Open AccessInnovation Urrets-Zavalia syndrome
Background: Surgeons often notice unexplained dilation of the pupil following an uncomplicated intra-ocular surgery. No definite line of treatment has been proposed for managing Urrets-Zavalia syndrome (UZS). The authors have previously documented the results of surgical pupilloplasty and have outlined this modality of treatment for cases with UZS. Purpose: To highlight the aspect of development of UZS post-operatively in the eyes following an intra-ocular surgery. Synopsis: The video highlights the aspect of prevalence of the persistently dilated pupil that is non-responsive to topical miotics. Apart from associated glare, these cases often have raised intra-ocular pressure because of appositional closure of the anterior chamber angle. Surgical pupilloplasty pulls the iris tissue centrally, eventually releasing the mechanical blockage and often breakage of the peripheral anterior synechias as demonstrated by intra-operative gonioscopy and anterior segment optical coherence tomography. Highlights: Performing a surgical pupilloplasty can resolve the UZS, and timely intervention can also prevent the development of secondary glaucoma because of fallback of the iris tissue on the structures of the anterior chamber angle. Online Video Link: https://youtu.be/IF_w8dVk5_w Key words: Dilated pupil, SFT, single-pass four-throw, surgical pupilloplasty, Urrets-Zavalia, UZS
- Open Access
- 25 June 2021
- Published by Elsevier in Ophthalmology Science
- Vol. 1 (2)
Advanced Vision Analyzer–Virtual Reality Perimeter
- 25 June 2021
- Published by Elsevier in Ophthalmology Science
- Vol. 1 (2)
Open AccessAdvanced Vision Analyzer–Virtual Reality Perimeter
- Open Access
- 1 January 2020
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 68 (1) , 71
Commentary: Capsule staining and its aftermath
- 1 January 2020
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 68 (1) , 71
Open AccessCommentary: Capsule staining and its aftermath
- 1 January 2019
- Published by Georg Thieme Verlag KG
1 Limbal Stem Cell Transplantation “Evolution and Techniques”
- 1 January 2019
- Published by Georg Thieme Verlag KG
1 Limbal Stem Cell Transplantation “Evolution and Techniques”
- 1 January 2019
- Published by Georg Thieme Verlag KG
7 Keratoprosthesis