Timo Zimmermann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Timo Zimmermann has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Aline Tschanz
Cell Biology and Biophysics Unit, EMBL Heidelberg, Heidelberg, Germany
1 shared publication - Anna Akhmanova
Cell Biology, Neurobiology and Biophysics, Department of Biology, Faculty of Science, Utrecht University, Utrecht, the Netherlands
1 shared publication - Anna Maria Steyer
EMBL Imaging Centre, European Molecular Biology Laboratory, Heidelberg, Germany
1 shared publication - Cyntha M. van Den Berg
Cell Biology, Neurobiology and Biophysics, Department of Biology, Faculty of Science, Utrecht University
1 shared publication - Dietrich Wyndham Michael Walsh
EMBL Imaging Centre, European Molecular Biology Laboratory, Heidelberg, Germany
1 shared publication - Euan Pyle
Institute of Structural and Molecular Biology, Birkbeck College
1 shared publication
Latest Publications
- Open Access
PinCorr: A high-pressure freezing carrier with intrinsic landmarks for cryo-correlative light and electron microscopy
Cryo-correlative light and electron microscopy methods enable targeted structural analysis of fluorescently labelled features in vitrified specimens. However, correlative workflows on high-pressure frozen samples often remain challenging due to the lack of persistent landmarks for reliable sample tracking and image registration between different microscopes. Standard high-pressure freezing carriers provide little intrinsic reference information, as the exposed sample surface is often smooth and rotationally ambiguous, complicating localisation of regions of interest across imaging platforms. Here, we introduce PinCorr, a 3-mm high-pressure freezing carrier with an integrated coordinate system formed by four asymmetrically arranged pillars with distinct geometries. These built-in landmarks remain visible after freezing and provide a stable, sample-independent reference frame for orientation and correlation between cryo-fluorescence microscopy and electron microscopy. We show that PinCorr supports fluorescence-guided cryo-volume imaging, serial lift-out for cryo-electron tomography and freeze-substitution workflows followed by room-temperature on-section correlation. PinCorr thus provides a hardware-based approach to establishing a persistent spatial reference frame in HPF-based correlative imaging workflows for thick and multicellular specimens.
Open AccessPinCorr: A high-pressure freezing carrier with intrinsic landmarks for cryo-correlative light and electron microscopy
Cryo-correlative light and electron microscopy methods enable targeted structural analysis of fluorescently labelled features in vitrified specimens. However, correlative workflows on high-pressure frozen samples often remain challenging due to the lack of persistent landmarks for reliable sample tracking and image registration between different microscopes. Standard high-pressure freezing carriers provide little intrinsic reference information, as the exposed sample surface is often smooth and rotationally ambiguous, complicating localisation of regions of interest across imaging platforms. Here, we introduce PinCorr, a 3-mm high-pressure freezing carrier with an integrated coordinate system formed by four asymmetrically arranged pillars with distinct geometries. These built-in landmarks remain visible after freezing and provide a stable, sample-independent reference frame for orientation and correlation between cryo-fluorescence microscopy and electron microscopy. We show that PinCorr supports fluorescence-guided cryo-volume imaging, serial lift-out for cryo-electron tomography and freeze-substitution workflows followed by room-temperature on-section correlation. PinCorr thus provides a hardware-based approach to establishing a persistent spatial reference frame in HPF-based correlative imaging workflows for thick and multicellular specimens.
- Open Access
Automated 3D multi-color single-molecule localization microscopy
Since its inception, single molecule localization microscopy (SMLM) has enabled imaging scientists to visualize biological structures with unprecedented resolution. Particularly powerful implementations capable of 3D, multi-color and high-throughput imaging have yielded key biological insights although widespread access to such technologies has been limited. The purpose of this protocol is to provide a guide for interested researchers to establish high-end SMLM in their laboratories. We detail the initial configuration and subsequent assembly of the SMLM, including instructions for alignment of all optical pathways, software/hardware integration and operation of the instrument. We describe validation steps including the preparation and imaging of test- and biological samples with structures of well-defined geometry and assist the user in troubleshooting and benchmarking performance. Additionally, we provide a walkthrough of the reconstruction of a super-resolved dataset from acquired raw images using the Super-resolution Microscopy Analysis Platform (SMAP). Depending on the instrument configuration, the cost of components is in the range $80,000 – 160,000, a fraction of the cost of a commercial instrument. A builder with some experience of optical systems is expected to require 3 - 6 months from the start of system construction to attain high-quality 3D and multi-color biological images.
Open AccessAutomated 3D multi-color single-molecule localization microscopy
Since its inception, single molecule localization microscopy (SMLM) has enabled imaging scientists to visualize biological structures with unprecedented resolution. Particularly powerful implementations capable of 3D, multi-color and high-throughput imaging have yielded key biological insights although widespread access to such technologies has been limited. The purpose of this protocol is to provide a guide for interested researchers to establish high-end SMLM in their laboratories. We detail the initial configuration and subsequent assembly of the SMLM, including instructions for alignment of all optical pathways, software/hardware integration and operation of the instrument. We describe validation steps including the preparation and imaging of test- and biological samples with structures of well-defined geometry and assist the user in troubleshooting and benchmarking performance. Additionally, we provide a walkthrough of the reconstruction of a super-resolved dataset from acquired raw images using the Super-resolution Microscopy Analysis Platform (SMAP). Depending on the instrument configuration, the cost of components is in the range $80,000 – 160,000, a fraction of the cost of a commercial instrument. A builder with some experience of optical systems is expected to require 3 - 6 months from the start of system construction to attain high-quality 3D and multi-color biological images.
- Open Access
- 8 February 2023
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 222 (4)
CSPP1 stabilizes growing microtubule ends and damaged lattices from the luminal side
Microtubules are dynamic cytoskeletal polymers, and their organization and stability are tightly regulated by numerous cellular factors. While regulatory proteins controlling the formation of interphase microtubule arrays and mitotic spindles have been extensively studied, the biochemical mechanisms responsible for generating stable microtubule cores of centrioles and cilia are poorly understood. Here, we used in vitro reconstitution assays to investigate microtubule-stabilizing properties of CSPP1, a centrosome and cilia-associated protein mutated in the neurodevelopmental ciliopathy Joubert syndrome. We found that CSPP1 preferentially binds to polymerizing microtubule ends that grow slowly or undergo growth perturbations and, in this way, resembles microtubule-stabilizing compounds such as taxanes. Fluorescence microscopy and cryo-electron tomography showed that CSPP1 is deposited in the microtubule lumen and inhibits microtubule growth and shortening through two separate domains. CSPP1 also specifically recognizes and stabilizes damaged microtubule lattices. These data help to explain how CSPP1 regulates the elongation and stability of ciliary axonemes and other microtubule-based structures.
- 8 February 2023
- Published by Rockefeller University Press in Journal of Cell Biology
- Vol. 222 (4)
Open AccessCSPP1 stabilizes growing microtubule ends and damaged lattices from the luminal side
Microtubules are dynamic cytoskeletal polymers, and their organization and stability are tightly regulated by numerous cellular factors. While regulatory proteins controlling the formation of interphase microtubule arrays and mitotic spindles have been extensively studied, the biochemical mechanisms responsible for generating stable microtubule cores of centrioles and cilia are poorly understood. Here, we used in vitro reconstitution assays to investigate microtubule-stabilizing properties of CSPP1, a centrosome and cilia-associated protein mutated in the neurodevelopmental ciliopathy Joubert syndrome. We found that CSPP1 preferentially binds to polymerizing microtubule ends that grow slowly or undergo growth perturbations and, in this way, resembles microtubule-stabilizing compounds such as taxanes. Fluorescence microscopy and cryo-electron tomography showed that CSPP1 is deposited in the microtubule lumen and inhibits microtubule growth and shortening through two separate domains. CSPP1 also specifically recognizes and stabilizes damaged microtubule lattices. These data help to explain how CSPP1 regulates the elongation and stability of ciliary axonemes and other microtubule-based structures.
- 1 October 2022
- Published by Erich Schmidt Verlag GmbH & Co. KG in Betriebliche Prävention
- No. 10
Was man aus der Formel 1 über Arbeitssicherheit im Betrieb lernen kann
- 1 October 2022
- Published by Erich Schmidt Verlag GmbH & Co. KG in Betriebliche Prävention
- No. 10
Was man aus der Formel 1 über Arbeitssicherheit im Betrieb lernen kann